Manual of SR258 intelligent controller
30
• 0-10: Speed control via 0 - 10 V signal
Note:
1. More information about connection of high efficiency pump see the paragraph (3.5
Connection with high efficiency pump)
2. Minimum pump speed: Under the adjustment menu MIN1, a relative minimum speed for
connected pumps can be allocated to the outputs R1.
3. Maximum pump speed: Under the adjustment menu MAX1, a relative maximum speed
for connected pumps can be allocated to the outputs R1.
4. When the devices which are not speed-controlled are used (e. g. motored valves), the
pump speed value of the corresponding relay must be set to 100 % or the control Mode
must be set to ONOF in order to deactivate pump speed control.
Menu structure
Main
menu
Submenu
1
Submenu
2
Factory
set
Adjustable
range
Step
per
adjust
Description
PUMP
Pump control mode
ONOF
ON
ON/OFF
Pump on/off ( for pump
without speed control)
PULS
OFF
ON/OFF
Pulse control (Burst
control
via
MIN1
30%
20-95%
5%