Azienda con sistema di gestione certificato
Company Quality Assurance conforming
31
ITA
S.H.S. s.r.l. Via F.lli Rosselli, 29 20027 Rescaldina (MI) – ITALY
Tel. +39 0331 466918 Fax. +39 0331 466147 www.shsitalia.it
7 – STEP
VALORE
DESCRIZIONE
0
FULL STEP
1
1 / 2 STEP
2
1 / 4 STEP
3
1 / 8 STEP
4
1 / 16 STEP
Set of microstepping
8 – CURRENT
DESCRIPTION
Motor phase current,set in mA.
9 – RID
DESCRIPTION
Motor phase current reduction, in % of the current set.
10 – QUOTE REV.
DESCRIPTION
Set of the “quote for revolution” value (please refer to the function mode description)
19 – ADD
DESCRIPTION
Set of the Modbus node address of the drive ( 1 ÷ 255 )
20 – BAUD
Set of the RS485 communication baud rate.
VALUE
DESCRIPTION
0
1200 bps
1
2400 bps
2
4800 bps
3
9600 bps
4
19200 bps
5
38400 bps
6
57600 bps
7
115200 bps
22 – COMMANDS
COMMAND OPERATION
DESCRIPTION
0
STOP
Stop motor
1
JOG CW
Endless moving in direct direction
2
JOG CCW
Endless moving in reverse direction
3
START REL CW
Start a relative positioning in direct direction
4
START REL CCW
Start a relative positioning in reverse direction
5
START ABS
Start an absolute positioning
6
HOMING
Perform the Homing procedure