2. Maintenance
1. To maintain the system in good performance and running
status, it is recommended to running the device at least once
per month.
3. Maintenance of the nozzle: Nozzle need to be cleaned up ,
and it is recommended that once every six months
(depending on the environment and frequency of use). In
the process of using the equipment, if the flame shape is
seriously deformed or the fuel injection line is significantly
deformed or coarsened, the nozzle should be removed
immediately for cleaning.
4. Maintenance of the O-ring: If it is found that the O-ring of the nozzle is damaged or ageing
when cleaning the nozzle, the O-ring should be replaced in time (material and size of O-ring:
fluororubber O-ring, the outermost diameter is 14 mm, and the line diameter is 2 mm).