5
1. LED Display Area:
RX: Radio receiving (reserved)
DMX: DMX signal. Flash means DMX signal available, otherwise no DMX signal
ERR: Light on when there is an error
PUMP: Light on when pump is running
2. Button Functions:
MENU: Switch interface to setup parameter;
+: Parameter Up
-: Parameter Down
ENTER: Confirm and save parameters (screen will flash when parameters saved)
Note: screen display will switch to main interface if not press button in 10s.
3. Welcome Interface:
Volcano202004
F5-01207005
First Line: Product model and software version
Second Line: Equipment series number
4. Main Interface:
DMX: 1 M: 6CH-P
P: 100 L: 50%
First Line
DMX DMX address 1(value from 1-512);
M Channel Mode 6CH-P
6CH-P: professional channel mode;
6CH-N: normal channel mode
6CH-S: safety channel mode
Second Line
P: Pressure Value 100 (100=10bar)
L: Liquid level 50%
5. Alert Message:
Alert Message
Explanation
E0
Test Mode
Safety lock located at TEST MODE
Factory Mode
DMX signal blocked in factory mode
Invert ON
When turned on, all angles will be mirrored
Prim Valve ON
Priming Valve is open
E1 Pressure Err
Pressuriser for about 13s, pressure value failed to reach 100%, system
will report E1.
Possible fault: No fuel, pump failure, pipeline problem etc.
E2 P Relief Err
Pipeline can't release pressure leads to pressure relief error.
Possible fault: pressure release valve failure, pipeline problem or
control system problem etc.
E4 ExtIgnite ON
The ExtIgnite Time is switched to ON