14
2. Professional Channel Mode
Channel
Function
CH1
Head NO.1 0~253: Firing OFF 254~255: Firing ON
CH2
Head NO.2 0~253: Firing OFF 254~255: Firing ON
CH3
Head NO.3 0~253: Firing OFF 254~255: Firing ON
CH4
Head NO.4 0~253: Firing OFF 254~255: Firing ON
CH5
Head NO.5 0~253: Firing OFF 254~255: Firing ON
CH6
Mode setup
0~49: Pressure Relief Mode (Emergency Stop)
50~200: Firing Mode
201~255: Pressure Relief Mode (Emergency Stop)
3. Safety Channel Mode
Channel
Function
CH1
Manual mode head selection
0: all five heads 1-51: head NO.1
52-102: head NO.2 103-153: head NO.3
154-204: head NO. 4 205-255: head NO.5
CH2
/
CH3
Ignition ON/OFF
0~253: ignition OFF;
254~255: ignition ON
CH4
Firing duration setup
0 and 255 is permanent firing (8s is limit duration firing time, 5 heads
simultaneously firing limit time is 2s);
1~254 correspond to 10~2540ms duration time (Manual firing duration = DMX
Value * 10ms)
CH5
Program sequence setup
0-2: no preset sequence; set according to CH1 and CH4.
3~255: preset sequence. DMX Value = 2+ Sequence No. * 2.55 (round off). CH1 and
CH4 invalid.
CH6
Mode setup
0~49: Pressure Relief Mode (Emergency Stop)
50~200: Firing Mode
201~255: Pressure Relief Mode (Emergency Stop)
▲
SHOWVEN Flamer Nozzle Information
SHOWVEN offer two types of nozzles to generate different effect height. Nozzle M and Nozzle L.
Standard configuration is Nozzle M.
1. Nozzle Types
●
SFSMA002 Nozzle M
Short flame
:
5~7m
Long flame
:
8~10m
●
SFSMA003 Nozzle L
Short flame
:
3~5m
Long flame
:
6~8m