Advanced menu:
Press “MENU” 3 seconds to enter the advanced setup interface, press MENU key to enter different
options, wait 3 seconds to return to the main interface.
Setting interface:
Press “MENU” to enter the Setting interface, press the “MENU” button to enter different options
until you return to the main interface.
Options
Set DMX Address
Manual Fountain
Fountain Height
Range
1-512
ON/OFF
1-10
Instructions
Set the DMX address.
Manual fountain switch, for testing purpose only.
Manual fountain, set shooting height, for testing purpose only.
Options
Range
500-610
ON/OFF
70-100
Factory Mode/
User Mode
Explanation
Set Temperature
Setup inner Core temperature. Please don't change
default value without engineer's suggestion from SHOWVEN.
Auto Heat
Auto preheat function switch after turning on
machine
Density
Adjust the sparks density. Please don't change default
value without engineer's suggestion from SHOWVEN.
Mode Selection
Factory Mode is factory debugging mode, User
Mode is using mode
Default Parameter
Mode
Press “ENTER” to restore all parameters to the factory
settings.
On/Off
Standby Switch
When it’s on, the machine can only generate spark
when pre-heating finish.
When using the DMX controller, the system takes 6 channels, each nozzle takes 2 channels.
First channel (nozzle 1)
Functions
0-15
Fountain OFF
16-255
Fountain ON, Height adjustable
Second Channel (nozzle 1)
Functions
60-80
Clear Material
20-40
Emergency Stop
0-10
240-255
Pre-heat OFF
(
Disable in Auto-heat
)
Pre-heat ON
(
Disable in Auto-heat
)
4