Страница 1: ...V1 0 SPARKULAR PRO USER MANUAL Showven Technologies Co Ltd ...
Страница 2: ...nd even damage the machine Maximum cascade of SPARKULAR PRO is 5 units 110V version no more than 3units with one standard power cable Otherwise it may damage the machine and even cause fire For better heat dissipation block the air intake and air outlet is prohibited Cover of nozzle of SPARKULAR PRO is prohibited Please check the nozzle before each show ensure the nozzle not blocked by foreign bod...
Страница 3: ...ion rate 20g min Interface NEUTRIK POWERCON TRUE1 3 pin waterproof DMX connectors Control DMX Operation Panel LED display area READY Flashing means heating up about 5min Turns from flashing into long on indicates that the machine is ready to work DMX Flashing shows that DMX signal is connected light OFF means there is no DMX signal FAULT Light ON when error occurs HEAT Light ON when system is heat...
Страница 4: ...ic working time The card is disposable can only use once First line shows DMX address Second Line shows inner temp and temp bar as well as error info if available Error Informations Explanation E0 System IC Systematic error E2 Temp Sensor Temperature sensor is not connected or damage E3 P Temp Over Chassis over temperature E4 Time Remain Activated time for machine is not enough need to swip RFID c...
Страница 5: ...nter the advanced setup interface press MENU key to enter different options wait 3 seconds to return to the main interface Options Set Temperature LCD Backlight Density Range 580 620 ON OFF 70 100 Explanation Options Range Explanation Default is 580 Please don t change default value without engineer s suggestion from SHOWVEN LCD screen backlight ON OFF Sparks density Mode Selection Factory Mode Us...
Страница 6: ...8 111 Fountain Height 4 112 135 Fountain Height 5 136 159 Fountain Height 6 160 183 Fountain Height 7 184 207 Fountain Height 8 208 231 Fountain Height 9 232 255 Fountain Height 10 Second channel Function 60 80 Clear Material perform after each show 20 40 Emergency Stop 0 10 Pre heat OFF disabled when auto heat ON 240 255 Pre heat ON disabled when auto heat ON ...
Страница 7: ...erwise it may leads to signal interference Do not soak the machine in water install on holder if necessary Install in below way Unload the 4 foot screw install SPARKULAR PRO via 4 M10 hole DMX Address Sparkular No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 ...
Страница 8: ...nce service for machines which with hardware malfunction except for the instrument damage caused by human factors in warranty period Please don t repair machine without factory permission 1 Damage caused by improper transportation usage management and maintenance or damage caused by human factors 2 Disassemble modify or repair products without Showven s permission 3 Damage caused by external reaso...
Страница 9: ......
Страница 10: ...hnologies Co Ltd Add Building B1 Changsha E Center No 18 Xiangtai Road Liuyang Economic Development Zone Changsha City 410300 Hunan Province P R China Tel 86 731 83833068 Web www showven cn E mail info showven cn ...