background image

 

USER MANUAL 

SPARKULAR FALL 

 

Please read this manual carefully before operating this product. 

Warranty card attached in the manual, please keep it well. 

 

SAFETY CONSIDERATIONS 

 

\  Never touch the nozzle of SPARKULAR FALL, danger of getting burnt 
\  Never touch the sparks which shooting out from the nozzle 
\  Unauthorized repair are prohibited, it may cause serious incident 
\  Keep SPARKULAR FALL dry and do NOT use in rain or snow 
\  Make sure lid of feeding hopper are well covered when use Sparkular Fall. Accidentally 
Burning of Composite Ti can only use sands to extinguish. Composite Ti should keep away from 
moisture and stored in a dry sealed environment  
\  Keep audience and flammable material at a minimum distance of 3m from SPARKULAR FALL 
and it’s drop sparks. Make sure sparks shoot out from Sparkular FALL can NOT touch any 
objects 
\  Ensure that children, animals and unauthorized persons don’t have access to the SPARKULAR 
FALL 
\  Clear material for Sparkular Fall is necessary both before the show and after the show, to 
clear the Composite Ti remains in the pipe. Check whether there are Composite Ti aggregate in 
the nozzle after each show, if any, please clean it up, or it will affect the  shooting effect or 
even damage Sparkular Fall 
\  The Sparkular FALL power supply cable (sparkular fall power supply EX-cable) maximum 
allowed cascade for Sparkular Fall is 6pcs (BT04)/ 3pcs (BT05), exceeded connecting may result 
in damage or even cause fire 
\  For better heat dissipation, block the air intake and air outlet is prohibited 
\  Cover of nozzle of Sparkular Fall is prohibited 
 

Description 

SPARKULAR FALL is hanging special effects equipment for indoor/outdoor use to generate daz
zling silver “waterfall” sparks effects. According to different usage scenarios, operator can self 
define various types of “water curtain” effects vary from 2m to 7m by use of different types of 
HC8200. 

 
 
 
 
 
 
 

Содержание BT04

Страница 1: ...USER MANUAL SPARKULAR FALL V1 0 2021 03 30 Showven Technologies Co Ltd ...

Страница 2: ...sure that children animals and unauthorized persons don t have access to the SPARKULAR FALL Clear material for Sparkular Fall is necessary both before the show and after the show to clear the Composite Ti remains in the pipe Check whether there are Composite Ti aggregate in the nozzle after each show if any please clean it up or it will affect the shooting effect or even damage Sparkular Fall The ...

Страница 3: ... After turning on machine it will automatically preheat around 5 minutes when the READY green light turns from flashing into long on indicates that the machine is ready to work DMX Flashing shows that DMX signal is connected otherwise is without signal FAULT When any malfunction the light turns on HEAT When the machine is heating signal light turns on 2 Control button area MENU short press to swit...

Страница 4: ... to identify parameters and types of granules Please note that granules RFID card can increase the single machine specific working time The card is disposable one card can only use one time Interface 1 Main Interface First line Display DMX address is 1 Second line Display the present inner core temperature and the temperature progress bar displays remianing time is 7 minutes and 24 seconds ...

Страница 5: ...e card E5 K Temp Over Inner core temperature is too high to shut down E6 Heat Fail Heating failed Options Range Explanation Set DMX Address 1 512 Set the DMX address machine become a wireless host and can send out DMX signal when its address is 1 Wireless Control ON OFF Wireless function switch you can match code when shows ON Manual Fountain ON OFF Manual fountain switch for testing purposes only...

Страница 6: ... the system takes 2 channels The First channel Functions 0 15 Firing OFF 16 135 Low Level Fountain ON 136 255 High Level Fountain ON The second channel Functions 60 80 Clear Material 20 40 Emergency Stop 0 10 Pre heat OFF Disable in Auto heat 240 255 Pre heat ON Disable in Auto heat 4 Wireless remote control mode If the remote control cannot work please check whether wireless function was turn on ...

Страница 7: ...e is occasionally not working may be caused by interference please press the start button again Wireless control is easily influenced by interference it suggests to stay as close to machine as possible when use remote controller and machines cannot use metal shielding 5 Wireless host Sparkular Fall mode requires communication cables In occasion of strong interference using the wireless host can av...

Страница 8: ...HC8200 Fall length Low Level Fall length High Level MEDIUM 2m 3m LARGE 3m 4m LARGE Ⅰ 4m 5m LARGE Ⅱ 5m 7m ...

Страница 9: ...thout factory permission Below situations NOT included in warranty service 1 Damage caused by improper transportation usage management and maintenance or damage caused by human factors 2 Disassemble modify or repair products without permission 3 Damage caused by external reasons lightning strike power supply etc 4 Damage caused by improper installation or use For product damage not included in war...

Страница 10: ......

Страница 11: ......

Страница 12: ...Showven Technologies Co Ltd Tel 86 731 83833068 Web www showven cn E mail info showven cn Add Liuyang Economic Development Zone Changsha 410300 Hunan Province P R China ...