background image

 

  

 

 

   

 

Order code: 30784 

Stage Blinder 1 LED 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the 

fixture. Be prepared to provide the model number, serial number and a brief description of the cause for 
the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is 
the customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 
Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 
01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery. 
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 

 

Содержание Stage Blinder 1 LED

Страница 1: ...Stage Blinder 1 LED V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Order code 30784 MANUAL ENGLISH...

Страница 2: ...One Stage Blinder Manual 8 Multiple Stage Blinders DMX Control 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 DMX Addressing 11 Menu Overview 12 Main Menu Options 13 1 DMX Address 14 2 DMX Cha...

Страница 3: ...perating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If improving your l...

Страница 4: ...closed while operating Always allow a free air space of at least 80 cm around the unit for ventilation Always disconnect power from the mains when device is not used or before cleaning Only handle th...

Страница 5: ...rranty becomes void Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European a...

Страница 6: ...he Mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YE...

Страница 7: ...ne number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform thi...

Страница 8: ...nels 1 and 2 channel mode Light source 1 x 80 W 2 x 40 W dual white 1800 K 3060 K COB LED Color temperature 2490 K Output 4190 lm Pod movement 180 smooth adjustment Beam angle 65 5 Field angle 99 5 Di...

Страница 9: ...tup and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in always make sure that the power supply matches the product specification volt...

Страница 10: ...nd other devices 05 Link the units as shown in Fig 02 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fo...

Страница 11: ...r own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio Basic microphone cable for all roun...

Страница 12: ...the DMX address of the third Stage Blinder should be 3 2 5 005 etc Make sure that you do not have any overlapping channels in order to control each Stage Blinder individually If two or more Stage Bli...

Страница 13: ...12 Order code 30784 Stage Blinder 1 LED Menu Overview...

Страница 14: ...f the device In case the device is not connected to a DMX controller a third line will appear on the screen indicating the behavior of the device when the DMX connection is lost For the settings regar...

Страница 15: ...dress The adjustment range is between 001 and 512 02 Press the ENTER button to confirm your choice 2 DMX Channel In this menu you can select the Channel Mode 01 Press the UP DOWN buttons to select the...

Страница 16: ...the UP DOWN buttons to toggle between Dimmer and Strobe 02 Press the ENTER button to select Dimmer or Strobe 03 Press the UP DOWN buttons to manually set the values for Dimmer or Strobe Dimmer 000 no...

Страница 17: ...buttons to toggle between Yes and No Select Yes and press ENTER to reset all settings to the factory defaults Select No and press ENTER to exit and cancel the reset DMX Channels 1 Channel Channel 1 D...

Страница 18: ...upply may cause a fuse to burn out If the fuse burns out the product will not function whatsoever If this happens follow the directions below to replace the fuse 01 Unplug the unit from electric power...

Страница 19: ...ction Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last...

Страница 20: ...ical properties Light source 1 x 80 W 2 x 40 W dual white 1800 K 3060 K COB LED Color temperature 2490 K Output 4190 lm Refresh rate 3100 Hz Pod movement 180 smooth adjustment Beam angle 65 5 Field an...

Страница 21: ...20 Order code 30784 Stage Blinder 1 LED Dimensions Design and product specifications are subject to change without prior notice Website www Showtec info Email service highlite com...

Страница 22: ...21 Order code 30784 Stage Blinder 1 LED Notes...

Страница 23: ...22 Order code 30784 Stage Blinder 1 LED...

Страница 24: ...2019 Showtec...

Отзывы: