background image

 

25 

Connection Cables

 

Take care of the connector cables, always holding them by the connectors and avoiding knots and 
twists when coiling them: This gives the advantage of increasing their life and reliability, which is always to 
your advantage. Periodically check that your cables are in good condition, that they are correctly wired 
and that all their contacts are perfectly efficient: a great number of problems are caused entirely by 
using unsuitable or faulty cables.

 

 

 

 

 

 
 

Maintenance 

The Spectral D4000 requires almost no maintenance. 

However, you should keep the unit clean.  

Otherwise, the fixture‟s light-output will be significantly reduced. 

Disconnect the mains power supply and 

then wipe the cover with a damp cloth. 

Wipe the front glass panel clean with glass cleaner and a soft 

cloth. Do not use alcohol or solvents. The front glass panel will require weekly cleaning, as smoke-fluid 
tends to build up residues, reducing the light-output very quickly. 

Do not immerse in liquid.  

Keep connections clean. Disconnect electric power, and then wipe the DMX connections 
with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying 
electric power. 

 

The operator has to make sure that safety-relating and machine-technical installations are to be 
inspected by an expert after every year in the course of an acceptance test.  
The operator has to make sure that safety-relating and machine-technical installations are to be 
inspected by a skilled person once a year. 

 

The following points have to be considered during the inspection:  

1.

 All screws used for installing the device or parts of the device have to be tightly connected and must  

    not be corroded. 

2.

 There may not be any deformations on housings, fixations and installation spots. 

3.

 Mechanically moving parts like axles, eyes and others may not show any traces of wearing. 

4.

 The electric power supply cables must not show any damages or material fatigue. 

 

Troubleshooting 

This troubleshooting guide is meant to help solve simple problems.  
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit 
operates properly, do not carry out following steps. 

1.

 If the device does not operate properly, unplug the device. 

2.

 Check the power from the wall, all cables etc. 

3.

 If all of the above appears to be O.K., plug the unit in again.

 

4.

 If you are unable to determine the cause of the problem, do not open the device, as this may  

    damage the unit and the warranty will become void. 

5. 

Return the device to your Showtec dealer. 

 

Содержание Spectral D4000

Страница 1: ...Spectral D4000 IP67 ORDERCODE 43504 ...

Страница 2: ... on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showtec info You can get some of the best quality best priced products on the market from Showtec So next time turn to Showtec for more great lighti...

Страница 3: ...g without ID addressing DMX Addressing with ID Address MENU OVERVIEW Creating a static color Activating an Auto Program Run Mode DMX 512 Address Personality ID Address Edit Custom Changing the Settings White Settings White Balance Activating the Password How to make your own Custom Program Modes 11 channel STAG 3 channel ARC 1 RGB 4 channel AR1 d Master Dimmer RGB 4 channel ARC 2 RGBW 5 channel AR...

Страница 4: ...o 50 000 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overall projection intensity SAFETY INSTRUCTIONS Every person involved with the installation operation and maintenance of this device has to be qua...

Страница 5: ...ime Make sure that no side forces can impact on the truss system The cable insert or the female part in the device must never be strained There must always be sufficient cable to the device Otherwise the cable may be damaged which may lead to deadly electrical shocks If the external cable is damaged it has to be replaced by a qualified technician If the lens is obviously damaged it has to be repla...

Страница 6: ...r safety issues Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Spectral D4000 is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the Spectral D4000 with the mounting bracket to the trussing system The Spectral D4000 must never be fixed swinging freely in the room...

Страница 7: ...double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check...

Страница 8: ...e barndoors to direct output optional LED display with lock out feature 15 optics Beam angle 11 Field angle 23 Lux 15 060 91 2 m Light source 48 LEDs 12 x 750 mA red 12 x 1 000 mA green 12 x 1 000mA blue 12 x 1 000 mA white Power and current 230 V 50 Hz 178 9 W 0 78 A operating 0 81 A inrush Double bracket yoke doubles as floor stand NOTE Knowledge of DMX is required to fully utilize this unit DMX...

Страница 9: ...ription 1 Master Dimmer 2 Red 3 Green 4 Blue 5 White Ar2 s Channel Description 1 Master Dimmer 2 Red 3 Green 4 Blue 5 White 6 Strobe HSV Channel Description 1 Hue 2 Saturation 3 Value Overview 1 2 Fig 1 1 18 x 1 Watt 6x Red 6x Green 6x Blue 2 Mountingbracket for Truss mounting ...

Страница 10: ... DMX signal connector OUT 4 5 6 7 Note You cannot plug a standard DMX cable directly into the connector Be sure to use the included special cable for DMX connection Female 3 pin DMX to special 3 pin Male Male 3 pin DMX to special 3 pin Female Powercable to special 3 pin Female ...

Страница 11: ...serial data link must be daisy chained in one single line To comply with the EIA 485 standard no more than 30 devices should be connected on one data link Connecting more than 30 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number ...

Страница 12: ...SSING 1 Connect a DMX controller example 50720 Showdesigner 1024 to the series of Spectral D4000 s 2 Each Spectral D4000 has 11 DMX channels DMX address LED Par 1 1 Par 2 12 Par 3 23 Par 4 34 etc 3 The ID address has not been set so therefore when using the controller CH11 must be inactive CH11 0 It is also possible to deactivate the ID address by selecting ID OFF from the Settings menu 4 Any DMX ...

Страница 13: ...esigner 1024 50720 Example 1 The figure above shows a simple DMX layout All the Spectral D4000 s have different ID addresses which allows the user to collectively control the whole group of Spectral D4000 s with the same DMX address by setting CH11 to 0 or to control each Spectral D4000 independently by first selecting the DMX address and then by using CH11 to locate the target ID address S howdes...

Страница 14: ...12 MENU OVERVIEW ...

Страница 15: ...DOWN buttons to change the static colors Red Green Blue White or the strobe speed 0 20Hz Press MENU to go 1 step back You can combine RED GREEN BLUE and WHITE to create an infinite range of colors 0 255 Red White Set the value of the red LEDs 0 255 Set the value of the white LEDs 0 255 Green Strobe Set the value of the green LEDs 0 255 Set the value of the flash 0 20Hz Blue Set the value of the bl...

Страница 16: ...14 Activating an Auto Program When you press ENTER in menu Auto Program you can choose one of the 10 built in programs You can also edit 10 custom programs ...

Страница 17: ...ration the RUN MODE does not work DMX 512 Address When you press ENTER in menu DMX 512 address you can set the DMX address You can choose your DMX address between 0 512 Personality Enter the PERSONALITY mode to select a DMX mode STAG ARC1 AR1d ARC2 AR2d AR2s HSV STAG 11 channels ARC1 3 channels AR1d 4 channels ARC2 4 channels AR2d 5 channels AR2s 6 channels HSV 3 channels ID Address Enter the ID A...

Страница 18: ...r the EDIT CUSTOM mode to edit the custom programs PR01 PR10 Each custom program has 30 steps which can be edited Each step allows the creation of a scene using RED GREEN BLUE WHITE STROBE TIMER FADE Changing the Settings ...

Страница 19: ...n set This means RGB 255 255 255 The color is displayed as you have calibrated the specific color in menu CAL2 RGBW When it is set to NO on RGB 255 255 255 the RGB values are not adjusted and the output is most powerful The RGB s parameter can be adjusted in CAL2 5 Enter POW menu to choose NORM or HIGH power operation mode When the Spectral D4000 is in normal mode the power consumption is about 90...

Страница 20: ...hite color will be made by the actual RGB values on the CAL2 Menu Activate Password Enter the KEY LOCK mode to select whether the access password is On or Off The Access Password UP DOWN UP DOWN When you have pressed ENTER in menu KEY ON it will take 30 seconds before the LED Par is locked When the password is activated the display will ask for password each time the fixture is powered on ...

Страница 21: ...ues Use Up Down to change the values Use Up Down to change the values Use Up Down to change the values Use Up Down to change the values Use Up Down to change the values Use Up Down to change the values And so you can add a maximum of 30 scenes After that you can start with PR02 and create a maximum of 30 scenes again You can repeat these steps until you ve reached PR10 step 30 This means it is pos...

Страница 22: ...Red Down Green 100 Blue 0 Red 0 Green 100 Blue Up Red 0 Green Down Blue 100 Red Up Green 0 Blue 100 Red 100 Green 0 Blue Down Red 100 Green Up Blue Up Red Down Green Down Blue 100 Red 100 Green 100 Blue 100 White 100 White 1 3200K White 2 3400K White 3 4200K White 4 4900K White 5 5600K White 6 5900K White 7 6500K White 8 7200K White 9 8000K White 10 8500K White 11 10000K 7 000 010 Strobe No Functi...

Страница 23: ...currently projected color When the fader is at 255 the intensity of the output is at its maximum RED GREEN BLUE WHITE SELECTION Channels 2 3 4 and 5 control the overall intensity of each respective color Channels 2 3 4 and 5 can be combined to create an unlimited range of colors COLOR MACROS WHITE BALANCE Channel 6 selects the required COLOR MACRO and whites in different colors Channel 6 has prior...

Страница 24: ...ontrol ARC2 Channel Value Function 1 000 255 Red 0 100 2 000 255 Green 0 100 3 000 255 Blue 0 100 4 000 255 White 0 100 DMX Control AR2 d Channel Value Function 1 000 255 Dimmer 0 100 2 000 255 Red 0 100 3 000 255 Green 0 100 4 000 255 Blue 0 100 5 000 255 White 0 100 DMX Control AR2 s Channel Value Function 1 000 255 Dimmer 0 100 2 000 255 Red 0 100 3 000 255 Green 0 100 4 000 255 Blue 0 100 5 00...

Страница 25: ...ddress 11 234 ID address 45 120 129 ID address 12 235 ID address 46 130 139 ID address 13 236 ID address 47 140 149 ID address 14 237 ID address 48 150 159 ID address 15 238 ID address 49 160 169 ID address 16 239 ID address 50 170 179 ID address 17 240 ID address 51 180 189 ID address 18 241 ID address 52 190 199 ID address 19 242 ID address 53 200 209 ID address 20 243 ID address 54 210 ID addre...

Страница 26: ...24 Beam Angles ...

Страница 27: ...ectric power The operator has to make sure that safety relating and machine technical installations are to be inspected by an expert after every year in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are to be inspected by a skilled person once a year The following points have to be considered during the inspection 1 All scre...

Страница 28: ... 15 060 91 2 m Power and current 230 V 50 Hz 178 9 W 0 78 A operating 0 81 A inrush Double bracket yoke doubles as floor stand Operating modes 11 channel STAG Master Dimmer RGBW Color Macro Strobe Auto Custom Programs Auto Speed Adjustment Dimmer Speed ID Address Selection 3 channel ARC 1 RGB 4 channel AR1 d Master Dimmer RGB 4 channel ARC 2 RGBW 5 channel AR2 d Master Dimmer RGBW 6 channel AR2 s ...

Страница 29: ......

Отзывы: