background image

3

  Never leave any cables lying around.

  Do not insert objects into air vents.

  Do not connect this device to a dimmerpack.

  Do not switch the device on and off in short intervals, as this would reduce the lamp’s life.

  Do not shake the device. Avoid brute force when installing or operating the device.

  Only use device indoor, avoid contact with water or other liquids.

  Only operate the device after having familiarized with its functions.

  Avoid flames and do not put close to flammable liquids or gases.

  Always check the regulations when using a class IIIB laser product.

  Always check and position the laser before anybody enters the room, when the laser is facing an

area with people.

  Always allow free air space of at least 50 cm around the unit for ventilation.

  Always disconnect power from the mains, when device is not used, before cleaning! Only handle the

power-cord by the plug. Never pull out the plug by tugging the power-cord.

  Make sure that the device is not exposed to extreme heat, moisture or dust.

  Make sure that the available voltage is not higher than stated on the rear panel.

  Make sure that the power-cord is never crimped or damaged. Check the device and the power-cord

from time to time.

  If device is dropped or struck, disconnect mains power supply immediately. Have a qualified

engineer inspect for safety before operating.

  If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not

switch it on immediately. The arising condensation water might damage your device. Leave the
device switched off until it has reached room temperature.

  If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely

(preferably in the original packing material), and return it to your Showtec dealer for service.

  For adult use only. Lighteffect must be installed out of the reach of children. Never leave the unit

running unattended.

  For replacement use fuses of same type and rating only.

  The user is responsible for correct positioning and operating of the laser. The manufacturer will not

accept liability for damages caused by the misuse or incorrect installation of this laser.

  This device falls under protection class I. Therefore it is essential to connect the yellow/green

conductor to earth.

  The laser will only work between 15-35ºC.

  After 3 hours working, you must shut off the laser and let the laser diode cool off for 30 minutes,

otherwise the laser could be damaged and the warranty becomes void.

 

Repairs, servicing and electric connection must be carried out by a qualified technician.

 

WARRANTY: Till one year after date of purchase.

CAUTION: AVOID EXPOSURE TO BEAM: Avoid direct eye contact with laser
light. Never intentionally expose your eyes or others to direct laser radiation.

Compliance Statement

Your Shogun Laser has been designed to comply with FDA and IEC Standards for it classification.
The Shogun is a Class IIIB laser product.

Laser Safety and Compliance Information

The Shogun is manufactured to comply with the IEC 60825-1 and in accordance with U.S. Food and Drug
Administrations (FDA) Standards Listed under FDA Document 21 CFR 1040 and subsequent laser notices.

Содержание Shogun DJ RG-100

Страница 1: ...Shogun DJ RG 100 ORDERCODE 32010...

Страница 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep yo...

Страница 3: ...eatures and Overview Backside Set Up and Operation One Shogun RG 100 Stand alone mode One Shogun RG 100 Sound Active One Shogun RG 100 Auto Mode Multiple Shoguns RG 100 Master Slave Multiple Shoguns R...

Страница 4: ...user serviceable parts Refer servicing to qualified technicians only IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any...

Страница 5: ...ensation water might damage your device Leave the device switched off until it has reached room temperature If your Showtec device fails to work properly discontinue use immediately Pack the unit secu...

Страница 6: ...ight output and the illuminated surface must be more than 0 8 meter The maximum ambient temperature ta must never be exceeded If this device is operated in any other way than the one described in this...

Страница 7: ...ith a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the laser always make sure that the area below the installation place is blocked and staying i...

Страница 8: ...ts 60 mW red laser 650nm 40 mW green laser 532nm DMX control via standard DMX controller 100 pre programmed effects 8 DMX control channels required Sound controlled via built in microphone Fuse 2A 250...

Страница 9: ...itting there is a rattling sound Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Remove the protection cover from the front of the laser When the lase...

Страница 10: ...sensitivity reaction to the music Auto Mode If Dip switches are set to 1000000000 then the fixture will play all pre programmed patterns Multiple Shoguns DJ RG 100 Master Slave 1 Fasten the effect li...

Страница 11: ...ogun DJ RG 100 Address Value DMX Dip Switches ON Unit 1 1 1 and for DMX 10 and 12 Unit 2 9 1 4 and for DMX 10 and 12 Unit 3 17 1 5 and for DMX 10 and 12 Unit 4 25 1 4 5 and for DMX 10 and 12 5 Supply...

Страница 12: ...dress values are determined set the appropriate DMX dip switches on each unit Example 1 If you want to give a Shogun DMX address133 you first have to find the number 133 in the DMX Chart 2 Then look a...

Страница 13: ...6 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 1...

Страница 14: ...ynamic Channel 3 X Position 0 255 Adjust X Position Channel 4 Y Position 0 255 Adjust Y Position Channel 5 Scanning Speed 0 255 From Fast 0 to Slow 255 Channel 6 Dynamic Pattern Play Speed 0 255 From...

Страница 15: ...rom electric power source 2 Insert a screwdriver into the slot in the fuse cover Turn the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 3 Remove the u...

Страница 16: ...amming DMX Channels 8 Signal input 3 pin XLR male Signal output 3 pin XLR female DMX control via standard DMX controller Laser 60 mW red Laser 650nm 40 mW green Laser 532nm Minimum distance Minimum di...