background image

 

  

 

 

   

 

Ordercode: 33090 

Performer Profile Mini MKII 3200K 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 
 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never lift the fixture holding it by the projector-head, as the mechanics may be damaged. Always 
hold the fixture by the transport handles. 

 

Never place any material over the LEDs or the lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmer pack. 

 

Do not switch the device on and off in short intervals, as this will reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes very hot). 
Allow the fixture to cool for at least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use the device indoors, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly 
fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep the case closed while operating. 

 

Always allow a free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord holding it by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced. 

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The fixture must be installed beyond the reach of children. Never leave the unit 
running unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

The user is responsible for correct positioning and operating of the Performer. The manufacturer will 
not accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

 

 

Содержание Performer Profile Mini MKII 3200K

Страница 1: ...Performer Profile Mini MKII 3200K V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 33090 MANUAL ENGLISH...

Страница 2: ...n 8 Lens Locations 9 Focusing the Beam 9 Gobo Slot 9 Color Frame Retaining Clip 10 Shaping the Beam 10 Rotating the Barrel 10 Control Modes 11 Manual Dimmer Control 11 Manual Dimmer Setup 11 Multiple...

Страница 3: ...xhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If i...

Страница 4: ...east 50 cm around the unit for ventilation Always disconnect power from the mains when device is not used or before cleaning Only handle the power cord holding it by the plug Never pull out the plug b...

Страница 5: ...ead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging tru...

Страница 6: ...o the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER N...

Страница 7: ...phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform...

Страница 8: ...Schuko power cable 3 pin DMX signal connector IN OUT Mounting Portable track mount Housing Die cast aluminum Cooling Forced convection Color Black IP rating IP20 Dimensions 150 x 106 x 225 mm LxWxH W...

Страница 9: ...supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject t...

Страница 10: ...ed tighten the beam focus controls Fig 04 Gobo Slot The gobo slot is located on the top of the barrel and is supposed to accommodate the gobo holder 33086 When the slot is not in use a small sheet met...

Страница 11: ...by pushing it sideways until it opens 02 Insert the color frame s 03 Lock the retaining clip by pushing it to the initial position until it is secured Fig 06 Shaping the Beam You may shape the beam wi...

Страница 12: ...des for air circulation 02 Always use a safety cable ordercode 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 Turn the manual dimmer control...

Страница 13: ...er devices 04 Link the units as shown in fig 09 Connect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourt...

Страница 14: ...wn cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio...

Страница 15: ...ipe the reflector 05 Insert the barrel into the reflector housing with the gobo slot on top line up the triangles on both parts 06 While pressing in gently rotate the barrel by 45 clockwise until it s...

Страница 16: ...MX cable or connectors a controller malfunction a light effect DMX card malfunction 01 Check the DMX setting Make sure that DMX addresses are correct 02 Check the DMX cable Unplug the unit change the...

Страница 17: ...anual DMX RDM Lux 1 m 15000 19 Color rendering 90Ra Color temperature 3200K Housing Die cast aluminum Connections Schuko power cable 3 pin DMX signal connector IN OUT Mounting Portable track mount Col...

Страница 18: ...17 Ordercode 33090 Performer Profile Mini MKII 3200K Notes...

Страница 19: ...18 Ordercode 33090 Performer Profile Mini MKII 3200K...

Страница 20: ...2019 Showtec...

Отзывы: