background image

 

  

 

 

   

 

Ordercode: 41521  

Infinity iW-720 

Connection with the mains 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 
 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN

 

RED

 

YELLOW/COPPER

 

FASE

 

BLUE 

BLACK 

SILVER 

NULL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 

Make sure that the device is always connected 

properly 

to the earth! 

 

 
 

 

 

 

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 
 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 

 

 

Содержание IW-720

Страница 1: ...Infinity iW 720 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 41521 MANUAL ENGLISH...

Страница 2: ...s Master Slave control 9 Multiple Infinity s DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 14 1 DMX Addressin...

Страница 3: ...s exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced I...

Страница 4: ...not used or before cleaning Only handle the power cord by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure...

Страница 5: ...nger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yoursel...

Страница 6: ...5 Ordercode 41521 Infinity iW 720 Mounting a clamp to the underside of the Infinity moving head Improper installation can cause serious damage to people and property...

Страница 7: ...ys a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your address 03 Your phone number 04 A brief des...

Страница 8: ...andard DMX controller User selectable Pan Tilt ranges 540 360 180 Reverse Pan Tilt movement Special Pan Tilt movement blackout Pan 0 540 Tilt 0 270 Pan Tilt resolution 16 bit Control DMX 512 Master Sl...

Страница 9: ...ment Fig 01 01 Lens 02 Menu Buttons LCD Display Backside 03 DMX signal connector IN 3 pin 04 DMX signal connector OUT 3 pin 05 Earth connection 06 Fuse F4AL 250V 07 Neutrik Powercon OUT 08 Neutrik Pow...

Страница 10: ...ays use a safety cable ordercode 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 When the Infinity is not connected by a DMX cable it functio...

Страница 11: ...ices 05 Link the units as shown in figure 4 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units...

Страница 12: ...DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Infinity s on a DMX data link 30 fixtures Data Cabling To link fixtures together you must obtain data ca...

Страница 13: ...hould be 1 001 the DMX address of the second Infinity should be 1 29 30 030 the DMX address of the third Infinity should be 30 29 29 059 etc Please be sure that you don t have any overlapping channels...

Страница 14: ...13 Ordercode 41521 Infinity iW 720 Menu Overview...

Страница 15: ...dress Setting Left Infinity Logo Right 1 DMX Addressing With this menu you can set the DMX address 01 Press the button and select 02 Press the button to confirm You can choose 512 different DMX addres...

Страница 16: ...o change the value from No to YES 04 Once you have selected the desired setting press the button to store your settings 05 If the device has been set to master all slave devices will follow the master...

Страница 17: ...set 4 colors Red 000 255 Green 000 255 Blue 000 255 White 000 255 07 If you press the OK button at the Reset function a new Menu will open 08 You can set 2 different reset options Pan Tilt Reset All...

Страница 18: ...ed the desired mode press the buttons to change the value from 000 to 255 04 If you press the OK button at the Manual Test a new Menu will open 05 You can set 7 different Test options 06 Once you have...

Страница 19: ...bit Channel 4 Tilt fine 16 bit Channel 5 PAN TILT Speed 0 255 From Max Speed 0 to Min Speed 255 Channel 6 Red 1 Dimmer intensity CH25 and CH26 must be open 0 255 Red from 0 100 Channel 7 Green 1 Dimm...

Страница 20: ...t be open 0 255 Blue from 0 100 Channel 17 White 3 Dimmer intensity CH25 and CH26 must be open 0 255 White from 0 100 Channel 18 Red 4 Dimmer intensity CH25 and CH26 must be open 0 255 Red from 0 100...

Страница 21: ...Color 16 85 89 Color 17 90 94 Color 18 95 99 Color 19 100 104 Color 20 105 109 Color 21 110 114 Color 22 115 119 Color 23 120 124 Color 24 125 129 Color 25 130 134 Color 26 135 139 Color 27 140 144 Co...

Страница 22: ...tter open 25 64 Strobe effect 1 from fast to slow 65 69 Shutter open 70 84 Strobe effect 2 fast on and slow off from fast to slow 85 89 Shutter open 90 104 Strobe effect 3 slow on and fast off from fa...

Страница 23: ...eed Slow 125 129 Fan Full Speed 130 134 Fan Temperature controlled 135 139 Dimming Fast 140 144 Dimming Smooth 145 239 No Function 240 247 XY Smoothing model open 248 255 XY Smoothing model to shut do...

Страница 24: ...ed 0 to Min Speed 255 Channel 4 Red Dimmer intensity CH10 and CH11 must be open 0 255 Red from 0 100 Channel 5 Green Dimmer intensity CH10 and CH11 must be open 0 255 Green from 0 100 Channel 6 Blue D...

Страница 25: ...4 Strobe effect 7 pulse strobe from fast to slow 185 189 Shutter open 190 204 Strobe effect 8 random pulse frequency strobe from fast to slow 205 209 Shutter open 210 224 Strobe effect 9 strobe light...

Страница 26: ...tion 8 23 Built in Macro 1 24 39 Built in Macro 2 40 55 Built in Macro 3 56 71 Built in Macro 4 72 87 Built in Macro 5 88 103 Built in Macro 6 104 119 Built in Macro 7 120 135 Built in Macro 8 136 151...

Страница 27: ...course of an acceptance test The operator has to make sure that safety relating and machine technical installations are to be inspected by a skilled person once a year The following points have to be...

Страница 28: ...e electric power source 02 Remove the 6 screws on the front side of the Infinity 03 Gently pull the front cover from the device 04 Disconnect the plug from the PCB 05 Remove the 2 screws holding the b...

Страница 29: ...e Replace the fuse See page 26 for replacing the fuse 05 If all of the above appears to be O K plug the unit in again 06 If you are unable to determine the cause of the problem do not open the Infinit...

Страница 30: ...nk not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is...

Страница 31: ...olor balance Separate RGBW adjustment On Board 16x2 Character display DMX control via standard DMX controller User selectable Pan Tilt ranges 540 360 180 Reverse Pan Tilt movement Special Pan Tilt mov...

Страница 32: ...2014 Showtec...

Отзывы: