IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 
 

 

Do not connect the string to a dimmer pack. 

 

The bulbs can get hot after prolonged use. Do not touch them with bare hands. Allow the bulbs to 
cool down before handling. 

 

Do not allow the bulbs to rest on anything. Keep bulbs at least 10 cm from other objects. 

 

Do not modify or cut any part of the string light. Do not use if any part of this string light has been cut 
or modified. 

 

Do not hang using screws, nails, staples, or any other sharp fasteners that may pierce, abrade, or 
otherwise damage the cable. 

 

Do not secure the cable of the string light with staples or nails, or place on sharp hooks or nails. 

 

Do not hang ornaments or other objects on the cable. 

 

Do not turn the bulbs in the sockets. The sockets are not threaded. Turning the bulb in the socket may 
damage the LED parts attached to the socket. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

This product is not intended for permanent installation. 

 

This product may be exposed to rain and moisture, as long as the bulbs hang at 90° angle to the 
ground. 

 

Make sure that the product is not exposed to extreme heat, moisture or dust. 

 

Make sure that the cable is never crimped or damaged. Check the cord before each use. 

 

If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The fixture must be installed beyond the reach of children. 

 

This product is intended for temporary outdoor use (IP54). Do not expose the product to conditions 
which exceed the product’s Ingress Protection (IP) rating. 

 

The user is responsible for correct installation and operating of the Festoonlight Q4 String. The 
manufacturer will not accept liability for damages caused by the misuse or incorrect installation of 
this device. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The maximum ambient temperature ta = 40 °C must never be exceeded. 

 

In order to eliminate wear and improve the device’s lifespan, during periods of non-use, completely 
disconnect from power source via breaker or by unplugging. 

 

If this device is operated in any other way, than the one described in this manual, the product may 
suffer damages and the warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 

 

You endanger your own safety and the safety of others! 

 
 

 

Содержание Festoonlight Q4 String

Страница 1: ...Festoonlight Q4 String V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Order code 41751 MANUAL ENGLISH...

Страница 2: ...s 2 Operating Determinations 3 Rigging 4 Return Procedure 5 Claims 5 Description of the Device 6 Installation 7 Setup with 1 3 Festoonlight Q4 Strings 7 Setup with 4 6 Festoonlight Q4 Strings 8 Setup...

Страница 3: ...packing Your shipment includes 1 x Showtec Festoonlight Q4 String 2 x end caps User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has...

Страница 4: ...ble is never crimped or damaged Check the cord before each use If your Showtec device fails to work properly discontinue the use immediately Pack the unit securely preferably in the original packing m...

Страница 5: ...essary use the extension cord supplied with the Festoonlight Q4 Controller Do not use more than 1 extension cord per controller Make sure that the structure onto which you are mounting the Festoonligh...

Страница 6: ...e number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this...

Страница 7: ...g length 15 m Distance between bulbs 0 75 m IP rating IP54 Weight 4 kg The Festoonlight Q4 String is designed to be operated ONLY with the Festoonlight Q4 Controller Note The Festoonlight Q4 String is...

Страница 8: ...nstalled outdoors Setup with 1 3 Festoonlight Q4 Strings 01 Connect the Festoonlight Q4 String to the dedicated connector on the Festoonlight Q4 Controller 02 Use the supplied extension cord if necess...

Страница 9: ...the booster 04 Connect the 5th and the 6th strings in a continuous line to the 4th string Note You can connect up to 6 Festoonlight Q4 Strings if you use a booster 05 Terminate the open end of the las...

Страница 10: ...ou should keep the unit clean Disconnect the mains power supply and then wipe the bulbs with a damp cloth Do not immerse in liquid Do not use alcohol or solvents Keep connections clean Disconnect elec...

Страница 11: ...mption 35 W Refresh rate 1 9 KHz Bulbs per string 20 pcs Bulb size 80 mm String length 15 m Distance between bulbs 0 75 m IP rating IP54 Weight 4 kg Controller Not included Max ambient temperature ta...

Страница 12: ...2019 Showtec...

Отзывы: