Maintenance  

The operator has to make sure that safety-relating and machine-technical installations are to be 
inspected by an expert after every year in the course of an acceptance test. 
The operator has to make sure that safety-relating and machine-technical installations are to be 
inspected by a skilled person once a year. 

 

The following points have to be considered during the inspection: 

1. 

All screws used for installing the device or parts of the device have to be tightly connected and must  

    not be corroded.

 

2. 

There may not be any deformations on housings, fixations and installation spots.

 

3. 

Mechanically moving parts like axles, eyes and others may not show any traces of wearing.

 

4. 

The electric power supply cables must not show any damages or material fatigue. 

 

The Showtec Expression 5000 requires almost no maintenance. However, you should keep the unit clean.  

Otherwise, the fixture’s light-output will be significantly reduced. 

Disconnect the mains power supply, and 

then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and 
a soft cloth. Do not use alcohol or solvents. 

The front lens will require weekly cleaning, as smoke-fluid tends to build up residues, reducing the light-
output very quickly. 
The cooling-fans and the internal lenses should be cleaned monthly with a soft brush. 

Please clean internal components once a year with a light brush and vacuum cleaner.  
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections 
with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying 
electric power. 

 
Replacing a Fuse 

Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the 
fuse burns out, the product will not function whatsoever. If this happens, 

follow the directions below to do 

so.

 

1.

 Unplug the unit from electric power source. 

2.

 

Insert a flat-head screwdriver into a slot in the fuse cover. Gently pry up the fuse cover. The fuse will  

    come out.

 

3.

 Remove the used fuse. If brown or unclear, it is burned out. 

4.

 Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to  

    use a fuse of the same type and specification. See the product specification label for details. 

 

 

Troubleshooting 

 

No Light, No Movement - All Products 

This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps 
below in sequence until a solution is found. Once the unit operates properly, do not carry out following 
steps. 
If the light effect does not operate properly, refer servicing to a technician. 
Response: Suspect three potential problem areas: the power supply, the lamp, the fuse. 

1.

 Power supply. Check that the unit is plugged into an appropriate power supply. 

2.

 The LEDs. Return the Expression 5000 to your Showtec dealer. 

3.

 The fuse. Replace the fuse. See page 27 for replacing the fuse. 

 

No Response to DMX 

Response: Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card 
malfunction. 

1.

 Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power.   

    Try your DMX control again. 

2.

 Determine whether the controller or light effect is at fault. Does the controller operate properly with  

    other DMX products ? If not, take the controller in for repair. If so, take the DMX cable and the light   
    effect to a qualified technician. 

 

See next page for more problem solving. 

 

Содержание Expression 5000

Страница 1: ...Expression 5000 V2 ORDERCODE 41364 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Страница 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Страница 3: ...in Programs Multiple Expression 5000s Master Slave control Multiple Expression 5000s DMX control Control Panel Control Mode DMX addressing MENU OVERVIEW Main Menu Options 1 Intro Menu DMX Addressing...

Страница 4: ...00 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may inclu...

Страница 5: ...east 50 cm around the unit for ventilation Always disconnect power from the mains when device is not used before cleaning or when replacing lamp Only handle the power cord by the plug Never pull out t...

Страница 6: ...shock lamp explosion crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues...

Страница 7: ...ty Connection with the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cabl...

Страница 8: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Страница 9: ...er selectable pan tilt ranges User selectable basic or advanced operating modes Power Consumption 140W max at full output Movement resolution selectable 8 16 bit Control On Board LCD display for Auto...

Страница 10: ...ole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Oper...

Страница 11: ...may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Expressions on a DMX data link 30 fixtures Data Cabling To li...

Страница 12: ...rol 1 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the Expression 5000 The pins 1 Earth 2 Signal 3 Signal 3 Lin...

Страница 13: ...al cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 5 Supply electric power Plug electric mains power cords into...

Страница 14: ...of the second Expression 5000 should be 1 12 13 013 the DMX address of the third Expression 5000 should be 13 12 25 025 etc Please be sure that you don t have any overlapping channels in order to cont...

Страница 15: ...13 Menu Overview Once you have entered a step you will see menu 5 2 5 12...

Страница 16: ...14...

Страница 17: ...ress the MODE button to scroll through 8 options of the menu To see menu 7 and 8 You have to enter password UP DOWN UP DOWN in menu EXTRA When you use the menu button the 2 hidden menus will now appea...

Страница 18: ...own buttons to go to the Fans menu 3 Press enter to open this menu Use the Up Down buttons to set the desired fan speed DMX Active With this menu you able to control the device by DMX 1 Press Menu unt...

Страница 19: ...nu 3 Press enter to open this menu Scroll through the menu until the display shows TEST 4 When you press ENTER the display will blink once and the device will start an internal test Channels Advanced...

Страница 20: ...ter button to store your setting 3 Range 1 Press Menu until the display shows Range 2 Press Enter and use the Up Down buttons to scroll through P Start P Finish T Start T Finish Use 3 Press enter to o...

Страница 21: ...ps please set the last step as 0 For example when you have 3 steps the setting should be Step 1 Time 4 Use Yes Step 2 Time 5 Use Yes Step 3 Time 0 Use Yes 6 Extra Password 1 Press Menu until the displ...

Страница 22: ...20 7 Calib...

Страница 23: ...nt color temperatures 3 There are 11 pre programmed White colors and RGB TO WHITE They can be edited by mixing Red Green and Blue 8 Default 1 Press Menu until the display shows Default 2 Press Enter a...

Страница 24: ...d 255 Channel 6 Red Dimmer must be open 0 255 Gradual adjustment Red from 0 100 Channel 7 Green Dimmer must be open 0 255 Gradual adjustment Green from 0 100 Channel 8 Blue Dimmer must be open 0 255 G...

Страница 25: ...ted after 5 seconds 150 159 Auto 2 activated after 5 seconds 160 169 Test activated after 5 seconds 170 179 Custom activated after 5 seconds 180 189 Sound 1 190 199 Sound 2 200 219 Reset activated aft...

Страница 26: ...0 255 Gradual adjustment Green from 0 100 Channel 5 Blue Dimmer must be open 0 255 Gradual adjustment Blue from 0 100 Channel 6 Macro Colors 0 10 No Function 11 30 Red 100 Green Up Blue 0 31 50 Red D...

Страница 27: ...169 Test activated after 5 seconds 170 179 Custom activated after 5 seconds 180 189 Sound 1 190 199 Sound 2 200 219 Reset activated after 5 seconds 220 235 No Function 236 239 DIM 0 activated after 5...

Страница 28: ...power Replacing a Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If the fuse burns out the product will not function whatsoever If this happens...

Страница 29: ...ug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixt...

Страница 30: ...anges User selectable basic or advanced operating modes Movement resolution selectable 8 16 bit Control On Board LCD display for Auto Custom Special Pan Tilt movement blackout Housing Flame retardant...