background image

3

  Only operate the fixture after having checked that the housing is firmly closed and all screws are

tightly fastened.

  Only operate the device after having familiarized with its functions.

  Avoid flames and do not put close to flammable liquids or gases.

  Always replace the lamp, when it is damaged or deformed due to the heat.

  Always keep case closed while operating.

  Always allow free air space of at least 50 cm around the unit for ventilation.

  Always disconnect power from the mains, when device is not used, before cleaning or when

replacing lamp! Only handle the power-cord by the plug. Never pull out the plug by tugging the
power-cord.

  Make sure that the device is not exposed to extreme heat, moisture or dust.

  Make sure that the available voltage is not higher than stated on the rear panel.

  Make sure that the power-cord is never crimped or damaged. Check the device and the power-cord

from time to time.

  If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due to

cracks or deep scratches.

  If device is dropped or struck, disconnect mains power supply immediately. Have a qualified

engineer inspect for safety before operating.

  If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not

switch it on immediately. The arising condensation water might damage your device. Leave the
device switched off until it has reached room temperature.

  If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely

(preferably in the original packing material), and return it to your Showtec dealer for service.

  For adult use only. Movinghead must be installed out of the reach of children. Never leave the unit

running unattended.

  For replacement use lamps and fuses of same type and rating only.

  Allow time to cool down, before replacing lamp.

  This device falls under protection class I. Therefore it is essential to connect the yellow/green

conductor to earth.

  During the initial start-up some smoke or smell may arise. This is a normal process and does not

necessarily mean that the device is defective.

 

Repairs, servicing and electric connection must be carried out by a qualified technician.

 

WARRANTY: Till one year after date of purchase.

OPERATING DETERMINATIONS

This device is not designed for permanent operation. Consistent operation breaks will ensure that the device
will serve you for a long time without defects.

The minimum distance between light-output and the illuminated surface must be more than 2 meters.

The maximum ambient temperature 

t

a

 must never be exceeded.

If this device is operated in any other way, than the one described in this manual, the product may suffer
damages and the

 

warranty becomes void.

Any other operation may lead to dangers like short-circuit, burns, electric shock, lamp explosion, crash etc.
You endanger your own safety and the safety of others!

CAUTION ! EYEDAMAGES !.

Avoid looking directly into the light source.

(meant especially for epileptics) !

Содержание Explorer 1200

Страница 1: ...Explorer 1200 ORDERCODE 40195...

Страница 2: ...n Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Страница 3: ...nd Overview Backside Installation Installing the Lamp Lamp Adjustment Set Up and Operation One Explorer Multiple Explorers Menu Settings DMX Protocol Control Panel Control Mode DMX addressing Channel...

Страница 4: ...ins with particular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never run the device without lamp Never ignite the lamp if the objec...

Страница 5: ...it has reached room temperature If your Showtec device fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Showt...

Страница 6: ...have to be used Use a clamp to mount the projector with the mounting bracket to the trussing system The projector must never be fixed swinging freely in the room The installation must always be secur...

Страница 7: ...people and property Connection with the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place Cable Pin Internation...

Страница 8: ...th 5 metal and 7 rotating glass gobos plus open 3 facet and 5 facet rotating prism 3 D prism Estriado Prism Adjustable Color Temperature 3200 K 6000 K DMX control via standard DMX controller 24 DMX co...

Страница 9: ...7 Backside 6 7 4 5 8 9 Fig 2 4 Fuse 10A 230V 5 ON OFF 6 DMX signal connector OUT 5 pin 7 DMX signal connector OUT 3 pin 8 DMX signal connector IN 5 pin 9 DMX signal connector IN 3 pin...

Страница 10: ...8...

Страница 11: ...Do not install lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 1 L...

Страница 12: ...imal distance between the lamp and the lens was already set during the installation with screw X only the Hot Spot the brightest part of the ray of light must be centered Turn in addition screw Y If t...

Страница 13: ...ir circulation 2 Plug the end of the electric mains power cord into a proper electric power supply socket Multiple Explorers 1 Fasten the effect light onto firm trussing Leave at least 1 meter on all...

Страница 14: ...12 Multiple Explorers Set Up DMX Set up Fig 4 Note Link all cables before connecting electric power...

Страница 15: ...13...

Страница 16: ...n you wish Channel 4 Tilt fine 16 bit Channel 5 Scan Speed Adjustment Channel 6 Lamp ON OFF RESET 0 127 No function 128 139 Lamp on after 3 seconds reset 140 229 No function 230 239 Lamp off after 3 s...

Страница 17: ...ect from slow to fast Channel 14 Rotating gobo index rotating gobo rotation Gobo wheel A Channel 15 Rotating Gobo wheel B 0 15 Open white 16 31 Gobo 1 32 47 Gobo 2 48 63 Gobo 3 64 79 Gobo 4 80 95 Gobo...

Страница 18: ...lose 212 233 Pulse Iris Fast open slow close 234 255 No function Channel 21 Zoom Channel 22 Focus Channel 23 Strobe 0 31 Shutter 32 63 Open 64 95 Strobe effect from slow to fast 96 127 Open 128 159 Pu...

Страница 19: ...e controller the unit has 24 channels When using multiple Explorers make sure you set the DMX addresses right Therefore the DMX address of the first Explorer should be 1 A001 the DMX address of the se...

Страница 20: ...ite The colour wheel can be positioned between two adjacent colours in any position It is also possible to rotate the colour wheel continuously at different speeds Rainbow effect in both directions 2...

Страница 21: ...19 Channels settings...

Страница 22: ...dichroic colour filters the gobo wheels the gobos and the internal lenses should be cleaned monthly with a soft brush To ensure proper functioning of the gobowheel we recommend lubricating the wheel...

Страница 23: ...he new gobo glazy side towards the lamp with distance ring Carefully put the spring gobo lock back gently press the spring gobo lock a little bit together Possibly use a pair of pliers to press the sp...

Страница 24: ...the steps below in sequence until a solution is found Once the unit operates properly do not carry out following steps If the light effect does not operate properly refer servicing to a technician Re...

Страница 25: ...ing One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until normal operation is regained unplug both connectors and connect them directly togethe...

Страница 26: ...an 0 530 Tilt 0 280 All lenses are anti reflection coated High luminous efficiency parabolic system Strobe effect with variable speed 1 flash 10 flashes sec DMX control via standard DMX controller Pri...

Страница 27: ...2006 Showtec...