Problem 

Probable cause(s) 

Remedy 

 
One or more 
fixtures are 
completely dead. 

No power to the fixture 

·Check that power is switched on and    
 cables are plugged in. 

Primary fuse blown. 

·Replace fuse. 
 

Fixtures reset 
correctly, but all 
respond 
erratically or not 
at all to the 
controller. 

The controller is not connected. 

·Connect controller. 

3-pin XLR Out of the controller 
does not match XLR Out of the first 
fixture on the link (i.e. signal is 
reversed). 

·Install a phase reversing cable  
 between the controller and the first  
 fixture on the link. 

 
 
 
 
 
 
 
 
 
 
Fixtures reset 
correctly, but 
some respond 
erratically or not 
at all to the 
controller. 

 
 
 
Poor data quality 

·Check data quality. If much lower  
 than 100 percent, the problem may  
 be a bad data link connection, poor  
 quality or broken cables, missing  
 termination plug, or a defective 
fixture  
 disturbing the link. 

 
Bad data link connection 

·Inspect connections and cables.  
 Correct poor connections. Repair or  
 replace damaged cables. 

Data link not terminated with 120 
Ohm termination plug. 

·Insert termination plug in output jack  
 of the last fixture on the link. 

Incorrect addressing of the fixtures.  ·Check address setting. 
 
 
One of the fixtures is defective and 
disturbs data transmission on the 
link. 

·Bypass one fixture at a time until  
 normal operation is regained: unplug  
 both connectors and connect them  
 directly together. 
·Have the defective fixture serviced 
by  
 a qualified technician. 

 
3-pin XLR Out on the fixtures does 
not match (pins 2 and 3 reversed). 

·Install a phase-reversing cable 

between the fixtures or swap pin 2 
and 3 in the fixture, that behaves 
erratically. 

Shutter closes 
suddenly 

The color wheel, gobo wheel, or a 
gobo has lost its index position and 
the fixture is resetting the effect. 

·Contact a technician for servicing if  
 the problem persists. 

 
No light 

The power supply settings do not 
match local AC voltage and 
frequency. 

·Disconnect fixture. Check settings  
 and correct if necessary. 

Lamp missing or blown 

·Disconnect fixture and replace lamp. 

 
Lamp cuts out 
intermittently. 

 
Fixture is too hot. 

·Allow fixture to cool. 
·Clean fan. 
·Make sure air vents at control panel  
 and front lens are not blocked. 
·Turn up the air conditioning. 

 

The power supply settings do not 
match local AC voltage and 
frequency. 

·Disconnect fixture. Check settings  
 and correct if necessary. 

Содержание Dreamer 31150

Страница 1: ...Dreamer ORDERCODE 31150...

Страница 2: ...howtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our...

Страница 3: ...iew Backside Installation Installing the Lamp Lamp Adjustment Set Up and Operation One Dreamer Multiple Dreamer DMX Protocol Control Panel Control Mode DMX addressing Stand alone mode Functions contro...

Страница 4: ...t that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing Your shipment includes Dreamer 1X 3m 3 pin IEC powercable User man...

Страница 5: ...he ground contact Never run the device without lamp Never ignite the lamp if the objective lens or any housing cover is open as discharge lamps may expose and emit a high ultraviolet radiation which m...

Страница 6: ...ng material and return it to your Showtec dealer for service For adult use only The device must be installed out of the reach of children Never leave the unit running unattended For replacement use la...

Страница 7: ...installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the projector always make sure that the area below the in...

Страница 8: ...4 glass and 1 metal gobo DMX control via standard DMX controller 5 DMX control channels required Sound controlled via built in microphone Manual focus Lamp MSD 200 MSD 250 or HSD 250 Fuse T5A 250V 1...

Страница 9: ...a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 1 Loosen the 2 screws on the...

Страница 10: ...light on an even surface wall As the optimal distance between the lamp and the lens was already set during the installation with screw C only the Hot Spot the brightest part of the ray of light must...

Страница 11: ...ten the effect light onto firm trussing Use a 30 kg rated or stronger C clamp fastened onto the Dreamer Leave at least 1 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the Dre...

Страница 12: ...ast Gobo 2 175 201 Bounce Slow Fast Gobo 3 202 228 Bounce Slow Fast Gobo 4 229 255 Bounce Slow Fast Gobo 5 Channel 3 Gobo Rotation 000 007 No rotation 008 255 Clockwise rotation Channel 4 Prism Rotati...

Страница 13: ...d Dreamer should be 1 5 6 A006 the DMX address of the third Dreamer should be 6 5 11 A011 etc Please be sure that you don t have any overlapping channels in order to control each Dreamer correctly If...

Страница 14: ...into the input of the master fixture and into the output of the last slave fixture in the data link in order to ensure proper transmission on the data link Functions control panel The control panel i...

Страница 15: ...e desired option Press to cancel the desired option and press to set the value To return to the menu press Please refer to chapter DMX Protocol for a detailed description No function No function Reset...

Страница 16: ...m Press until the display shows or If the display shows with actually stored address Press the display shows Press to play the program the display shows with actually stored address If you want addres...

Страница 17: ...moke fluid tends to build up residues reducing the light output very quickly The cooling fans dichroic colour filters the gobo wheel the gobos and the internal lenses should be cleaned monthly with a...

Страница 18: ...lamp Replace the old lamp with a new one with the same specifications See page 7 for replacing lamps 3 The fuse Replace the fuse See page 18 for replacing the fuse No Response to DMX Response Suspect...

Страница 19: ...jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a tim...

Страница 20: ...ll lenses are anti reflection coated High luminous efficiency parabolic mirror and double condenser lens DMX control via standard DMX controller Sound controlled via built in microphone Wheel control...

Страница 21: ......

Отзывы: