13 

Addressing 

 

With this menu you can set the DMX address or address a fixture as a master/slave. 
 
         - DMX addressing 

1)

 Press 

, until the display shows 

2)

 Press 

 to confirm, the display will show                (with actually stored address). 

 
    And press 

and      to select the required address 

, press 

to confirm.

  

 

 

 

3)

 Press 

, the chosen address is shown on the display. 

 

 

Operating options 

These options allow you to modify the Dreamer’s operating behavior. 
Press 

to select the desired option, Press 

to cancel the desired option and press 

 to set the value. 

To return to the menu, press 

 

 

 
Please refer to chapter “ DMX Protocol” for a detailed description. 

 

             – No function 
 

 

             – No function 
 

  - Reset function 

This option enables the Dreamer to index all effects (function) and return to their standard 
positions. Press 

,

 until the display shows 

  or  

 . 

If the display shows 

 (with actually stored address). Press 

, the display shows 

 .  

Press 

 to run a reset. The option enables the Dreamer to index all effects (functions) and 

return to their standard positions, the display shows 

 , ( with actually stored address ). If 

you want address no reset, don’t select 

 
 
 
 
 
 
 
 
 

Содержание Dreamer 31150

Страница 1: ...Dreamer ORDERCODE 31150...

Страница 2: ...howtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our...

Страница 3: ...iew Backside Installation Installing the Lamp Lamp Adjustment Set Up and Operation One Dreamer Multiple Dreamer DMX Protocol Control Panel Control Mode DMX addressing Stand alone mode Functions contro...

Страница 4: ...t that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing Your shipment includes Dreamer 1X 3m 3 pin IEC powercable User man...

Страница 5: ...he ground contact Never run the device without lamp Never ignite the lamp if the objective lens or any housing cover is open as discharge lamps may expose and emit a high ultraviolet radiation which m...

Страница 6: ...ng material and return it to your Showtec dealer for service For adult use only The device must be installed out of the reach of children Never leave the unit running unattended For replacement use la...

Страница 7: ...installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the projector always make sure that the area below the in...

Страница 8: ...4 glass and 1 metal gobo DMX control via standard DMX controller 5 DMX control channels required Sound controlled via built in microphone Manual focus Lamp MSD 200 MSD 250 or HSD 250 Fuse T5A 250V 1...

Страница 9: ...a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 1 Loosen the 2 screws on the...

Страница 10: ...light on an even surface wall As the optimal distance between the lamp and the lens was already set during the installation with screw C only the Hot Spot the brightest part of the ray of light must...

Страница 11: ...ten the effect light onto firm trussing Use a 30 kg rated or stronger C clamp fastened onto the Dreamer Leave at least 1 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the Dre...

Страница 12: ...ast Gobo 2 175 201 Bounce Slow Fast Gobo 3 202 228 Bounce Slow Fast Gobo 4 229 255 Bounce Slow Fast Gobo 5 Channel 3 Gobo Rotation 000 007 No rotation 008 255 Clockwise rotation Channel 4 Prism Rotati...

Страница 13: ...d Dreamer should be 1 5 6 A006 the DMX address of the third Dreamer should be 6 5 11 A011 etc Please be sure that you don t have any overlapping channels in order to control each Dreamer correctly If...

Страница 14: ...into the input of the master fixture and into the output of the last slave fixture in the data link in order to ensure proper transmission on the data link Functions control panel The control panel i...

Страница 15: ...e desired option Press to cancel the desired option and press to set the value To return to the menu press Please refer to chapter DMX Protocol for a detailed description No function No function Reset...

Страница 16: ...m Press until the display shows or If the display shows with actually stored address Press the display shows Press to play the program the display shows with actually stored address If you want addres...

Страница 17: ...moke fluid tends to build up residues reducing the light output very quickly The cooling fans dichroic colour filters the gobo wheel the gobos and the internal lenses should be cleaned monthly with a...

Страница 18: ...lamp Replace the old lamp with a new one with the same specifications See page 7 for replacing lamps 3 The fuse Replace the fuse See page 18 for replacing the fuse No Response to DMX Response Suspect...

Страница 19: ...jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a tim...

Страница 20: ...ll lenses are anti reflection coated High luminous efficiency parabolic mirror and double condenser lens DMX control via standard DMX controller Sound controlled via built in microphone Wheel control...

Страница 21: ......

Отзывы: