background image

 

  

 

 

   

 

Ordercode: 30277 

Compact Power Lightset  4 RGBW 

 

Before  your initial start-up, please make sure that there is no damage caused  by transportation. Should 
there be any, consult your dealer and do not use the device. 
To maintain perfect condition and to ensure  a safe operation, it is absolutely necessary  for the user to 
follow the safety instructions and warning notes written in this manual.  
Please consider that damages caused  by manual modifications to the device are not subject to 
warranty. This device contains no user-serviceable  parts. Refer  servicing to qualified technicians only. 
 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non -observance  of 
this manual or any unauthorized modification to the device. 

 

 

Never let the power cord come into contact with other cables!  Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never place any material over the lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect  this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this would reduce  the device’s lifespan. 

 

Do not touch the device’s housing bare-handed  during its operation. Allow the fixture to cool for at 
least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device.  

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked  that the housing is firmly closed and all screws are 
tightly fastened. 

 

Only operate the device after having familiarized with its functions.  

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep case closed while operating. 

 

Always allow free air space  of at least 50 cm around the unit for ventilation.  

 

Always disconnect power from the mains, when device is not used or before  cleaning! Only  handle 
the power cord by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust.  

 

Make sure that the available voltage is not higher than stated on the rear panel.  

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced to prevent  its functions from being impaired, 
due to cracks or deep scratches. 

 

If device was dropped or struck, disconnect  mains power supply immediately. Have a qualified 
engineer  inspect for safety before operating. 

 

If the device has been exposed  to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached  room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably  in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Device must be installed out of reach of children. Never leave the unit running 
unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement, use fuses of same type  and rating only. 

 

The user is responsible for correct positioning and operating of the Compact Power Lightset 4 RGBW. 
The manufacturer will not accept liability for damages caused  by the misuse or incorrect installation 
of this device.  

 

This device falls under protection class I. Therefore  it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electrical connection must be carried out by a qualified technician. 

 

WARRANTY:  Till one year  after date of purchase. 

 

Содержание COMPACT POWER LIGHTSET 4 RGBW

Страница 1: ...Compact Power Lightset 4 RGBW V1 Highlit e Int ernat ional B V Vest ast raat 2 6468 EX K erkrade t he Net herlands Ordercode 30277 MANUAL ENGLISH...

Страница 2: ...s 8 Multiple Compact Power Lightsets 4 RGBW Master Slave control 8 Multiple Compact Power Lightsets 4 RGBW DMX512 Mode 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 DMX Control Mode 11 DMX Add...

Страница 3: ...ct Power Lightset 4 RGBW Stand T bar carrying bag and hard case incl IEC powercable 5 0m 2 safety eyes User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the domi...

Страница 4: ...lose to flammable liquids or gases Always keep case closed while operating Always allow free air space of at least 50 cm around the unit for ventilation Always disconnect power from the mains when dev...

Страница 5: ...ightset 4 RGBW is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the Compact Power Lightset 4 RGBW with the mounting bracket to the trussing...

Страница 6: ...our phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perf...

Страница 7: ...ate 7 8 Khz Control Mode DMX512 LED Source 5x 4 in 1 RGBW LEDs 4W per spot Dimmer 0 100 Strobe 0 20Hz Beam angle 25 Consumption Power 90 Watt 3 pin female XLR socket and 3 pin male XLR socket IEC Powe...

Страница 8: ...ply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to w...

Страница 9: ...0 5 meter on all sides for air circulation 02 When the Compact Power Lightset is not connected by a DMX cable it functions as a stand alone device 03 If device is set to or then the fixture will play...

Страница 10: ...er devices 04 Link the units as shown in Fig 03 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second and third units 05...

Страница 11: ...ures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please u...

Страница 12: ...should be 20 19 39 039 etc Please be sure that you do not have any overlapping channels in order to control each Compact Power Lightset 4 RGBW correctly If two or more Compact Power Lightsets 4 RGBW...

Страница 13: ...12 Ordercode 30277 Compact Power Lightset 4 RGBW Menu overview...

Страница 14: ...Setup button you can choose a different DMX Mode Select a DMX channel mode between The display will blink 2 Built in Programs With this menu you can choose a built in program 01 Press the Mode button...

Страница 15: ...iew 2 info s about the device 01 Press the Mode button until the display shows 02 Press the Setup button to open the menu 03 Press the Up Down buttons to choose 04 Press the Setup button to open the m...

Страница 16: ...sen Yes the factory settings will be restored The fixture will start up in the Auto Run mode 12 In the menu option you can set the device to Off or Hold 13 If you choose Off the fixture will blackout...

Страница 17: ...device 01 Press the Mode button until the display shows 02 If the device has not been set to slave it is automatically classified as a master device All slave devices will follow the master movement...

Страница 18: ...000 W200 28 34 Color 4 R255 G050 B000 W000 35 41 Color 5 R255 G150 B000 W000 42 48 Color 6 R255 G255 B000 W000 49 55 Color 7 R255 G255 B000 W075 56 62 Color 8 R000 G255 B000 W255 63 69 Color 9 R000 G2...

Страница 19: ...75 Program 07 76 85 Program 08 86 95 Program 09 96 105 Program 10 106 115 Program 11 116 125 Program 12 126 135 Program 13 136 145 Program 14 146 155 Program 15 156 165 Program 16 166 175 Program 17...

Страница 20: ...low to high frequency Channel 3 Red color intensity CH1 must be set between 001 255 0 255 Gradual adjustment Red from 0 100 Channel 4 Green color intensity CH1 must be set between 001 255 0 255 Gradua...

Страница 21: ...olor intensity 0 255 Gradual adjustment Blue from 0 100 Channel 4 White color intensity 0 255 Gradual adjustment White from 0 100 Channel 5 Red color intensity 0 255 Gradual adjustment Red from 0 100...

Страница 22: ...W050 77 83 Color 11 R000 G255 B000 W000 84 90 Color 12 R000 G255 B050 W000 91 97 Color 13 R000 G255 B150 W000 98 104 Color 14 R000 G255 B255 W000 105 111 Color 15 R000 G255 B255 W075 112 118 Color 16...

Страница 23: ...m Speed CH5 must be set between 006 235 0 255 Gradual speed adjustment from slow to fast Channel 6 Sound Sensitivity CH5 must be set between 236 255 0 255 Gradual sound sensitivity from low sensitivit...

Страница 24: ...tment Blue from 0 100 Channel 4 White color intensity 0 255 Gradual adjustment White from 0 100 Channel 5 Red color intensity 0 255 Gradual adjustment Red from 0 100 Channel 6 Green color intensity 0...

Страница 25: ...ue from 0 100 Channel 12 White color intensity 0 255 Gradual adjustment White from 0 100 Channel 13 Red color intensity 0 255 Gradual adjustment Red from 0 100 Channel 14 Green color intensity 0 255 G...

Страница 26: ...e intensity from low to high frequency Channel 4 Red color intensity 0 255 Gradual adjustment Red from 0 100 Channel 5 Green color intensity 0 255 Gradual adjustment Green from 0 100 Channel 6 Blue co...

Страница 27: ...en from 0 100 Channel 14 Blue color intensity 0 255 Gradual adjustment Blue from 0 100 Channel 15 White color intensity 0 255 Gradual adjustment White from 0 100 Channel 16 Red color intensity 0 255 G...

Страница 28: ...ke sure connections are thoroughly dry before linking equipment or supplying electric power Replacing a Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to bur...

Страница 29: ...rrectly but some respond erratically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or b...

Страница 30: ...e Signal output 3 pin XLR female Electro mechanical effects Light source 5x 4 in 1 RGBW LEDs 4W per spot Beam Angle 25 Dimmer 0 100 Strobe 0 20Hz Color Range RGBW Cooling Aluminum heat sink Display LC...

Страница 31: ...30 Ordercode 30277 Compact Power Lightset 4 RGBW Dimensions T bar 4 parcans Stand Weight stand 3 7 kg...

Страница 32: ...2016 Showtec...

Отзывы: