Connection with the mains 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 
 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN

 

RED

 

YELLOW/COPPER

 

PHASE

 

BLUE 

BLACK 

SILVER 

NEUTRAL 

 

YELLOW/GREEN 

GREEN 

GREEN 

PROTECTIVE GROUND 

 

Make sure that the device is always connected 

properly 

to the earth! 

 
Improper installation can cause serious damage to people and property! 

 

 

 

 

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 

Содержание compact par 7 MKII

Страница 1: ...Compact Par 7 MKII V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42595 MANUAL ENGLISH...

Страница 2: ...mpact Pars Master Slave control 9 Multiple Compact Pars DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 14 1 DMX...

Страница 3: ...mperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If improving your lifespan exp...

Страница 4: ...t the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged...

Страница 5: ...hers Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried...

Страница 6: ...n proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 You...

Страница 7: ...0 240 VAC 50 60Hz Drive current 0 68A 110V 0 32A 240V Power consumption 28W max FO full output Power linking 20pcs 110V 38pcs 240V DMX control Via standard DMX controller On Board Display for easy Set...

Страница 8: ...7 Ordercode 42595 Compact Par 7 MKII Frontside Fig 01 01 Frontside Mounting bracket with Screw 02 Lens...

Страница 9: ...al connector OUT NOTE Knowledge of DMX is required to fully utilize this unit Installation Remove all packing materials from the Compact Par 7 MKII Check that all foam and plastic padding is removed C...

Страница 10: ...cable it functions as a stand alone device 05 Please see page 14 and 15 for more information about the manual control functions Multiple Compact Pars Master Slave control 01 Fasten the effect light o...

Страница 11: ...er devices 05 Link the units as shown in figure 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourt...

Страница 12: ...recommended number of Compact Pars on a DMX data link 30 fixtures Maximum recommended number of Compact Pars on a Power link 20 fixtures 110V Maximum recommended number of Compact Pars on a Power lin...

Страница 13: ...Please be sure that you don t have any overlapping channels in order to control each Compact Par 7 MKII correctly If two or more Compact Pars are addressed similarly they will work similarly Controll...

Страница 14: ...13 Ordercode 42595 Compact Par 7 MKII Menu Overview...

Страница 15: ...lso choose the desired DMX Mode 04 Press the SETUP button to set 3 different DMX Modes Use the Up Down buttons to choose between 3 6 or 7 Channels 2 Slave Mode With this menu you can set the Master or...

Страница 16: ...cy and the Program Running Speed by pressing the SETUP button 06 Use the UP DOWN buttons to change the values Speed from 01 99 and FL Flash Frequency from 00 99 5 Manual Color control With this menu y...

Страница 17: ...0 100 6 Channels Channel 1 Dimmer Colors RGB must be open 0 255 From black to brightest Channel 2 Red Dimmer intensity CH1 must be set between 0 255 0 255 Red from 0 100 Channel 3 Green Dimmer intens...

Страница 18: ...ity CH1 must be set between 0 255 0 255 Blue from 0 100 Channel 5 Built in Programs 0 24 No function 25 49 Built in Program 01 50 74 Built in Program 02 75 99 Built in Program 03 100 124 Built in Prog...

Страница 19: ...technical installations are to be inspected by a skilled person once a year The following points have to be considered during the inspection 01 All screws used for installing the device or parts of th...

Страница 20: ...II as this may damage the unit and the warranty will become void 06 Return the device to your Showtec dealer No Response to DMX Response Suspect the DMX cable or connectors a controller malfunction a...

Страница 21: ...n Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fix...

Страница 22: ...ned housing ensures an optimum heat dissipation during operation Mounting Multiple mounting possibilities DMX control Via standard DMX controller On Board Display for easy Set Up Control DMX 512 Built...

Страница 23: ...22 Ordercode 42595 Compact Par 7 MKII Dimensions c...

Страница 24: ...2015 Showtec...

Отзывы: