SHOWTEC City Painter 150 Скачать руководство пользователя страница 4

2

WARNING

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY

BEFORE YOUR INITIAL START-UP!

SAFETY INSTRUCTIONS

Every person involved with the installation, operation and maintenance of this device has to:

-

 be 

qualified

-

 

follow  the instructions of this manual

Before your initial start-up, please make sure that there is no damage caused by transportation. Should
there be any, consult your dealer and do not use the device.

To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to follow
the safety instructions and warning notes written in this manual.

Please consider that damages caused by manual modifications to the device are not subject to warranty.

This device contains no user-serviceable parts. Refer servicing to qualified technicians only.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance of
this manual or any unauthorized modification to the device.

  Never let the power-cord come into contact with other cables! Handle the power-cord and all

connections with the mains with particular caution!

  Never remove warning or informative labels from the unit.

  Never use anything to cover the ground contact.

  Never run the device without lamp!

  Never ignite the lamp if the objective-lens or any housing-cover is open, as discharge lamps may

expose and emit a high ultraviolet radiation, which may cause burns.

  Never lift the fixture by holding it at the projector-head, as the mechanics may be damaged. Always

hold the fixture at the transport handles.

  Never look directly into the light source.

  Never leave any cables lying around.

  Never unscrew the screws of the rotating gobo, as the ball bearing will otherwise be opened.

  Do not insert objects into air vents.

  Do not connect this device to a dimmerpack.

  Do not switch the device on and off in short intervals, as this would reduce the lamp’s life.

  If the lamp has been turned OFF, let the lamp cool down for 15 minutes, before turning the lamp ON

again.

  Do not touch the device’s housing bare-handed during its operation (housing becomes very hot).

  Do not shake the device. Avoid brute force when installing or operating the device.

CAUTION!

Keep this device away from rain and moisture!

Unplug mains lead before opening the housing!

CAUTION! Be careful with your operations.

With a dangerous voltage you can suffer

a dangerous electric shock when touching the wires!

Содержание City Painter 150

Страница 1: ...City Painter 150 ORDERCODE 40901...

Страница 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep yo...

Страница 3: ...lling the Lamp Set Up and Operation One City Painter Multiple City Painters Line Board DMX Protocol Control Mode DMX 512 Mode DMX Addressing DMX Channels DMX Dip Switch Setting 2P Function Mode switch...

Страница 4: ...caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never run the device without lamp Never ignite the lamp if the objective lens or any ho...

Страница 5: ...e If your Showtec device fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Showtec dealer for service For adul...

Страница 6: ...mproper installation can cause serious damage to people and property Connection with the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is co...

Страница 7: ...andard DMX controller 6 DMX control channels required IP 65 Protection degree Stand alone control or Master Slave control Dimmer Color Temp 4200 K Lamp HCI CDM 150 Note If the lamp has been turned OFF...

Страница 8: ...ed for Damages caused by non observance are not subject to warranty Procedure 1 Loosen the 4 screws on the aluminum housing Gently remove the metal housing 2 Draw the mirrors total of 6 mirrors in 3 l...

Страница 9: ...le to connect the City Painters and other devices The pins 1 Earth 2 Signal 3 Signal 3 Link the units as shown in figure 4 Connect a DMX signal cable from the first unit s DMX out socket to the second...

Страница 10: ...8 Line Board...

Страница 11: ...d be 13 6 19 019 etc Unit No Address Binary Dip Switch Setting Unit 1 1 Unit 2 7 Unit 3 13 Unit 4 19 Please be sure that you don t have any overlapping channels in order to control each City Painter c...

Страница 12: ...ht to dark Blue Channel 5 Macro Colourwheel Rainbow Linear color change following the movement of the slider 0 25 Open white 26 50 Yellow 51 76 Aubergine 77 102 Blue 103 128 Red 129 154 Green 155 180...

Страница 13: ...11 DMX Dip Switch Setting...

Страница 14: ...n a data link and one of them is set as a master master mode DIP switch 1 ON and the rest as slaves slave mode DIP switch 1 OFF The DMX address of all the slaves are assigned and on that particular sl...

Страница 15: ...ep Blue Blue Green Yellow Red approx 20 sec time Code 16 Aubergine Deep Blue Blue Green Yellow Red approx 10 sec time Code 17 Aubergine Blue Yellow approx 30 sec time Code 18 Aubergine Blue Yellow app...

Страница 16: ...ses should be cleaned monthly with a soft brush Please clean internal components once a year with a light brush and vacuum cleaner Keep connections clean Disconnect electric power and then wipe the DM...

Страница 17: ...lamp Replace the old lamp with a new one with the same specifications See page 7 for replacing lamps 3 The fuse Replace the fuse See page 15 for replacing the fuse No Response to DMX Response Suspect...

Страница 18: ...t jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a ti...

Страница 19: ...000 hr 3300K ordercode 80965 Showtec HCI CDM 150 9000 hr 4000K ordercode 80964 Electro mechanical effects DMX control via standard DMX controller Color effect 3 Colors Red Yellow Blue white CYM Color...

Страница 20: ...2005 Showtec...

Отзывы: