IMPORTANT:

 

The manufacturer will not accept liability for any resulting damages caused by the non-
observance of this manual or any unauthorized modification to the device. 

 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not open the device and do not modify the device. 

 

Never use the device during thunderstorms, unplug the device immediately. 

 

Never look directly into the light source. 

 

Do not switch the device on and off in short intervals, as this would reduce the system’s life. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 
tightly fastened. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only 
handle the power-cord by the plug. Never pull out the plug by tugging the power-cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

If the external cable is damaged, it has to be replaced by a qualified technician. 

 

If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due 
to cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your device. Leave 
the device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Light effect must be installed out of the reach of children. Never leave the unit 
running unattended. 

 

For replacement use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the Cameleon Flood 7. The 
manufacturer will not accept liability for damages caused by the misuse or incorrect installation 
of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

During the initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase.

 

 
 
 
 

 

 

CAUTION ! EYEDAMAGES !. 

Avoid looking directly into the light source. 

(meant especially for epileptics) !

 

 

Содержание Cameleon Flood 7 RGB

Страница 1: ...Cameleon Flood 7 RGB ORDERCODE 42689...

Страница 2: ...sign and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant sh...

Страница 3: ...9 One Cameleon Flood Manual color control 9 One Cameleon Flood NO Sound control 9 Multiple Cameleon Floods Master Slave control 10 Multiple Cameleon Floods DMX Control 11 Fixture Linking 12 Data Cabl...

Страница 4: ...conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of over...

Страница 5: ...the power cord is never crimped or damaged Check the device and the power cord from time to time If the external cable is damaged it has to be replaced by a qualified technician If the lens is obvious...

Страница 6: ...Always let the installation be carried out by an authorized dealer Procedure If the Cameleon Flood 7 is lowered from the ceiling or high joists professional trussing systems have to be used Use a clam...

Страница 7: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Страница 8: ...erconnector DMX Connection Dedicated IP65 connector Lens Plate Tempered Glass Control DMX Auto Program Master slave IR remote Dimmer 0 100 Strobe 0 20Hz Beam Angle 40 degrees Housing Die Cast Aluminiu...

Страница 9: ...ni DMX In 4 3 pin mini DMX Out 5 Power Out 6 Power IN Please make sure to obtain the XLR 3 pin to mini 3 pin cable 42708 to connect the device to DMX Please make sure to also obtain the remote control...

Страница 10: ...extension cable 3m 42706 Power connection cable 3m 42707 DMX Extension cable 3m 42708 Special XLR to small 3 pin cable 3m 42709 Endcap when using the Cameleon outdoors make sure the last device in a c...

Страница 11: ...functions as a stand alone device Please see page 14 for more information about the Auto run visual effects One Cameleon Flood Built in Programs 1 Fasten the effect light onto firm trussing Leave at...

Страница 12: ...hown in Fig 3 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units You can use the same function...

Страница 13: ...MX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 5 Supply electric power Plug the end of the mains power cord into proper electric power suppl...

Страница 14: ...lities and connector made by Neutrik Ordercode FL71150 1 5m FL713 3m FL716 6m FL7110 10m DMX Control Mode The fixtures are individually addressed on a data link and connected to the controller The fix...

Страница 15: ...ss this button to activate the Built in program Mode The LEDs will blink yellow once indicating you re in built in program mode Then the LEDs will dim briefly and then indicate its current built in pr...

Страница 16: ...er one value one digit is 6 seconds 6 Static Color Mode R 2 G 3 B 4 Press one of these buttons to activate manual color setting in combination with one of the numeric buttons 0 9 to select a certain p...

Страница 17: ...spots 3 Mechanically moving parts like axles eyes and others may not show any traces of wearing 4 The electric power supply cables must not show any damages or material fatigue Troubleshooting No Ligh...

Страница 18: ...tion plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120...

Страница 19: ...dicated IP65 Powerconnector DMX Connection Dedicated IP65 connector Lens Plate Tempered Glass Dimmer 0 100 Strobe 0 20Hz Beam Angle 40 degrees Housing Die Cast Aluminium Black Powder Coat Finish Cooli...

Страница 20: ......

Отзывы: