Before the initial start-up, please make sure that there is no damage caused by transportation.  
Should there be any, consult your dealer and do not use the device. 
 
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes contained in this manual. 
 
Please consider that damages caused by manual modifications to the device are not subject to 
warranty. 
 
This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 
 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never modify, bend, mechanically strain, put pressure on, pull or heat up the power cord. 

 

Never strain the cable insert or the female part in the device. There must always be sufficient cable 
going to the device. Otherwise, the cable will be damaged, which can cause serious damage. 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never lift the device holding it by the projector-head, as the mechanics may be damaged. Always 
hold the device by the transport handles. 

 

Never place any material over the LEDs or lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Never use the device during thunderstorms, unplug the device immediately. 

 

Never leave various parts of the packaging  (plastic bags, polystyrene  foam, nails,  etc.) within 
children’s reach, as they are potential sources of danger.

 

Do not insert objects into air vents. 

 

Do not open the device and do not modify the device.

 

Do not connect this device to a dimmer pack. 

 

Do not switch the device on and off in short intervals, as this will reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes hot). Allow 
the device to cool for at least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only operate the device after having checked if the housing is firmly closed and all screws are tightly 
fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep the case closed while operating. 

 

Always allow a free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord holding it by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

Make sure that the core diameter of extension cords and power cords is sufficient for the required 
power consumption of the device. 

 

If the lens or LEDs are obviously damaged, they have to be replaced to prevent its functions from 
being impaired, due to cracks or deep scratches. 

 

If the external cable is damaged, it has to be replaced by a qualified technician.

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

Содержание Cameleon Flood 6NW

Страница 1: ...Cameleon Flood 6NW V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42677 MANUAL ENGLISH...

Страница 2: ...Multiple Cameleon Floods DMX Control 11 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addressing 13 Menu Overview 14 Main Menu Options 15 1 Auto program 15 2 DMX Address DMX...

Страница 3: ...ec Cameleon Flood 6NW 1x Schuko to 3 pins IP 65 Power cable 1 5m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the accelera...

Страница 4: ...open the device and do not modify the device Do not connect this device to a dimmer pack Do not switch the device on and off in short intervals as this will reduce the device s life Do not touch the d...

Страница 5: ...hase Operating Determinations This device is not designed for permanent operation Consistent operation breaks will ensure that the device will serve you for a long time without defects The minimum dis...

Страница 6: ...the installation site is secured and that there are not any unauthorized people around The Cameleon Flood 6NW can be placed on a flat stage floor or mounted to any kind of truss with a clamp Improper...

Страница 7: ...r 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check...

Страница 8: ...tion rate IP 65 Lens Plate Tempered Glass Control DMX Auto program Master slave Manual Dimmer 0 100 Strobe 0 15Hz Housing Die Cast Black Aluminum Cooling Convection no fans Connections Dedicated Power...

Страница 9: ...white 02 IR sensor 03 Mounting bracket Backside Fig 02 04 Special mini 3 pin DMX cable IN IP 65 05 Safety eye 06 Special mini 3 pin DMX cable OUT IP 65 07 Special mini 3 pin power cable IN IP 65 08 OL...

Страница 10: ...Manual mode Master slave DMX 512 1CH 2CH One Cameleon Flood Auto program 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Always use a safety...

Страница 11: ...04 Link the units as shown in Fig 03 Connect the first unit s DMX out socket with the second unit s in socket using the 42707 427076 DMX Extension cable Link the second third and fourth units using t...

Страница 12: ...n socket using the 42707 427076 DMX Extension cable Link the second and third units using the 42707 427076 DMX Extension cable 05 Supply electric power Plug electric mains power cords into each unit s...

Страница 13: ...DAP Audio Basic microphone cable for allround use bal XLR M 3 pin XLR F 3 pin Ordercode FL01150 1 5 m FL013 3 m FL016 6 m FL0110 10 m FL0115 15 m FL0120 20 m DAP Audio X type data cable XLR M 3 pin X...

Страница 14: ...eon Flood should be 3 2 5 005 etc Please be sure that you do not have any overlapping channels in order to control each Cameleon Flood correctly If two or more Cameleon Floods are addressed similarly...

Страница 15: ...14 42677 Cameleon Flood 6NW Menu Overview The Cameleon Flood 6NW will show the current software version and actual temperature at start up...

Страница 16: ...ent range is between 01 100 from slow to fast 06 If you choose Strobe press the SET button to open the submenu 07 Press the UP DOWN buttons to increase decrease the strobe frequency The adjustment ran...

Страница 17: ...buttons until the display shows Manual 02 Press the SET button to open the menu the display will show 03 Press the UP DOWN buttons to choose between Dimmer or Strobe 04 If you choose Dimmer press the...

Страница 18: ...e UP DOWN buttons to choose the desired dimming curve out of the 4 available options 04 Press the SET button to confirm your choice 5 2 Dimmer Speed In this menu you can adjust the dimming speed of th...

Страница 19: ...menu the display will show 03 Press the UP DOWN buttons to select On or Off 04 The Sync option is a tool which helps to keep multiple fixtures synchronized when using them in master slave mode 05 If y...

Страница 20: ...select Yes or No 04 If you choose Yes and confirm it with the SET button the device will be reset to its factory default settings 05 If you choose No the device will keep current settings 6 Informatio...

Страница 21: ...ontrol the device with the remote control Built in program 01 Press the button to activate the Built in program mode 02 Press the button to set the program speed 03 Press the and buttons to increase d...

Страница 22: ...screws used for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may not be any deformations on housings fixations and installation spots 03...

Страница 23: ...your Showtec dealer 04 If all of the above appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Cameleon Flood as this may damage the uni...

Страница 24: ...Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixtu...

Страница 25: ...nical effects Light source 6 x 8W Power LED Neutral white Output 2050 Lumen Beam angle 39 Max distance 10m Colour temperature 4000K CRI 80 Lens Plate Tempered Glass Connections Dedicated Power cable I...

Страница 26: ...25 42677 Cameleon Flood 6NW Dimensions...