13
42677
Cameleon Flood 6NW
Control Panel
A) OLED Display
B) MODE button
C) SET button
D) UP button
E) DOWN button
Fig. 05
Control Mode
The fixtures are individually addressed on a data-link and connected to the controller.
The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it,
the controller will display the saved DMX address, next time.)
DMX Addressing
The control panel on the front side of the base allows you to assign DMX fixture addresses, which is the first
channel with which the Cameleon Flood will respond to the controller.
Please note, when you use the controller, the unit has 2 channels.
When using multiple Cameleon Floods, make sure you set the DMX addresses right.
Therefore, the DMX address of the first Cameleon Flood should be 1(001); the DMX address of the second
Cameleon Flood should be 1+2=3 (003); the DMX address of the third Cameleon Flood should be 3+2=5
(005), etc. Please, be sure that you do not have any overlapping channels in order to control each
Cameleon Flood correctly. If two or more Cameleon Floods are addressed similarly, they will work
similarly.
Controlling:
After having addressed all Cameleon Flood fixtures, you may now start operating these via your lighting
controller.
Note: After switching on, the Cameleon Flood will automatically detect whether DMX 512 data is
received or not. If not, the problem may be:
•
The XLR cable from the controller is not connected with the input of the Cameleon Flood.
•
The controller is switched off or defective, the cable or connector is detective, or the signal wires are
swapped in the input connector.
Note: It is necessary to insert an XLR termination plug (with 120 Ohm) in the last fixture in order to ensure
proper transmission on the DMX data link.
Display Off after 60 seconds
When no button is pressed for 60 seconds, the display will turn off.
To light up the display, you have to press the MODE, SET, UP or DOWN button.