Ordercode: 42671 

 

Cameleon Flood 15 Q4 

Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to 
run synchronized shows of two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures the 
data link can support. 
 

Important: 

Fixtures on a serial data link must be daisy-chained in a single line. To comply with the  
EIA-485 standard, no more than 30 devices should be connected on one data link. 
Connecting more than 30 fixtures on one serial data link without the use of a DMX 
optically isolated splitter may result in deterioration of the digital DMX signal. 

 

Maximum recommended DMX data link distance: 100 meters 
Maximum recommended number of fixtures on a DMX data link: 30 fixtures 
Maximum recommended number of fixtures on a Power link: 8 units @120V 
Maximum recommended number of fixtures on a Power link: 16 units @230V 
 

 

Data Cabling 

To link fixtures together, you must obtain data cables. You can purchase DAP Audio certified DMX cables 
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable, 
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic 
interference. 
 

DAP Audio DMX Data Cables 

 

DAP Audio Basic microphone cable for allround use. bal. XLR/M 3-pin > XLR/F 3-pin. 

Ordercode

 

FL01150 (1,5 m), FL013 (3 m), FL016 (6 m), FL0110 (10 m), FL0115 (15 m), FL0120 (20 m). 

 

DAP Audio X-type data cable XLR/M 3-pin > XLR/F 3-pin. 

Ordercode

 FLX0175 (0,75 m), 

FLX01150 (1,5 m), FLX013 (3 m), FLX016 (6 m), FLX0110 (10 m). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®.

 Ordercode

 FL71150 (1,5 m), FL713 (3 m), FL716 (6 m), FL7110 (10 m). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®.

 Ordercode

 FL7275 (0,75 m), FL72150 (1,5 m), FL723 (3 m), FL726 (6 m), FL7210 (10 m). 

 

DAP Audio 110 Ohm cable with digital signal transmission. 

Ordercode

 FL0975 (0,75 m), 

FL09150 (1,5 m), FL093 (3 m), FL096 (6 m), FL0910 (10 m), FL0915 (15 m), FL0920 (20 m). 

 

DAP Audio DMX adapter: 3-pin/5-pin. 

Ordercode

 FLA30. 

 

Note:

 Use the special DMX cables for DMX connection. 

42707

  DMX Extension cable for Cameleon series (3m) 

427076

 DMX Extension cable for Cameleon series (6m) 

42708

  DMX Input cable for Cameleon series (3m) 

 

 

Содержание Cameleon Flood 15 Q4

Страница 1: ...Cameleon Flood 15 Q4 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42671 MANUAL ENGLISH...

Страница 2: ...eon Floods Master Slave control 10 Multiple Cameleon Floods DMX Control 11 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addressing 13 Menu Overview 14 Main Menu Options 15 1...

Страница 3: ...Showtec Cameleon Flood 15 Q4 1x Schuko to 3 pins IP 65 Power cable 1 5m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the a...

Страница 4: ...efore handling Do not shake the device Avoid brute force when installing or operating the device Only use the device indoors avoid contact with water or other liquids Only operate the fixture after ha...

Страница 5: ...emperature of 40 C If this device is operated in any other way than the one described in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to danger...

Страница 6: ...n with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELL...

Страница 7: ...number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this c...

Страница 8: ...n White 1505 Lumen Full Output 3434 Lumen Beam Angle 25 Max distance 20m Protection rate IP 65 Lens Plate Tempered Glass Control DMX Auto Program Built in programs Master slave Manual Dimmer 0 100 Str...

Страница 9: ...RGBW ProLight Opto Hornet Series 02 Mounting bracket Backside Fig 02 03 Special mini 3 pin DMX cable IN IP 65 04 Special mini 3 pin DMX cable OUT IP 65 05 Special mini 3 pin power cable IN IP 65 06 O...

Страница 10: ...rcode 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 When the Cameleon Flood is not connected with a DMX cable it functions as a stand alone...

Страница 11: ...Link the units as shown in Fig 03 Connect the first unit s DMX out socket with the second unit s in socket using the 42707 427076 DMX Extension cable Link the second and third units using the 42707 42...

Страница 12: ...it s in socket using the 42707 427076 DMX Extension cable Link the second and third units using the 42707 427076 DMX Extension cable 05 Supply electric power Plug electric mains power cords into each...

Страница 13: ...Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and a...

Страница 14: ...e third Cameleon should be 11 10 21 021 etc Please be sure that you do not have any overlapping channels in order to control each Cameleon correctly If two or more Cameleons are addressed similarly th...

Страница 15: ...14 Ordercode 42671 Cameleon Flood 15 Q4 Menu Overview...

Страница 16: ...s the UP DOWN buttons to choose Program 02 Press the SET button to open the menu 03 Press the UP DOWN buttons to choose between Mode Color Speed or Strobe 04 Once you have chosen Mode press the SET bu...

Страница 17: ...nu 07 Press the UP DOWN buttons to choose 4 6 or 10 DMX channels 4 Master slave With this menu you can set the device as a slave 01 While in the main menu press the UP DOWN buttons to choose Slave 02...

Страница 18: ...adjust the dimming of the device by choosing a dimming curve 01 While in Settings menu press the UP DOWN buttons to choose Curves Select 02 Press the SET button to open the menu 03 Press the UP DOWN...

Страница 19: ...r the safety lock is active 01 While in Settings menu press the UP DOWN buttons to choose Lock 02 Press the SET button to open the menu 03 Press the UP DOWN buttons to choose the desired option 04 You...

Страница 20: ...ust be set between 1 255 0 255 Gradual adjustment Red from 0 100 Channel 4 Green Dimmer intensity CH1 must be set between 1 255 0 255 Gradual adjustment Green from 0 100 Channel 5 Blue Dimmer intensit...

Страница 21: ...126 132 Color 18 R000 G000 B255 W100 133 139 Color 19 R000 G000 B255 W050 140 146 Color 20 R000 G000 B255 W000 147 153 Color 21 R075 G000 B255 W000 154 160 Color 22 R160 G000 B255 W000 161 167 Color 2...

Страница 22: ...ages or material fatigue The Cameleon Flood 15 Q4 requires almost no maintenance However you should keep the unit clean Otherwise the fixture s light output will be significantly reduced Disconnect th...

Страница 23: ...tically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing terminat...