background image

 

  

  

 

 

 

Ordercode: 50787 

RDM Splitter Pro 4 Channel DMX 

Multiple RDM Splitters DMX Set Up 

 

 

Fig. 03 

Note : Link all cables before connecting electric power 

 

Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to 

run synchronized shows of two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures the 

data link can support. 
 

Important:  Fixtures on a serial data link must be daisy-chained in a single line. To comply with the  

EIA-485 standard, no more than 30 devices should be connected on one data link. 
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically 

isolated splitter may result in deterioration of the digital DMX signal. 

 

Maximum recommended DMX data link distance: 100 meters 

Maximum recommended number of fixtures on a DMX data link: 30 fixtures 

 

Data Cabling 

To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX cables 

directly from a dealer/distributor or construct your own cable. If you choose to create your own cable 

please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic 
interference. 

 
DAP Audio DMX Data Cables 

 

DAP Audio Basic microphone cable for allround use. bal. XLR/M 3-pin > XLR/F 3-pin. Ordercode 

FL01150 (1,5 m), FL013 (3 m), FL016 (6 m), FL0110 (10 m), FL0115 (15 m), FL0120 (20 m). 

 

DAP Audio X-type data cable XLR/M 3-pin > XLR/F 3-pin. Ordercode FLX0175 (0,75 m), 

FLX01150 (1,5 m), FLX013 (3 m), FLX016 (6 m), FLX0110 (10 m). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®. Ordercode FL71150 (1,5 m), FL713 (3 m), FL716 (6 m), FL7110 (10 m). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 

Neutrik®. Ordercode FL7275 (0,75 m), FL72150 (1,5 m), FL723 (3 m), FL726 (6 m), FL7210 (10 m). 

 

DAP Audio 110 Ohm cable with digital signal transmission. Ordercode FL0975 (0,75 m), 

FL09150 (1,5 m), FL093 (3 m), FL096 (6 m), FL0910 (10 m), FL0915 (15 m), FL0920 (20 m). 

 

DAP Audio DMX adapter: 3-pin/5-pin. Ordercode FLA30. 

 

 

Содержание 50787

Страница 1: ...RDM Splitter Pro 4 Channel DMX V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50787 MANUAL ENGLISH...

Страница 2: ...ith the mains 4 Return Procedure 5 Claims 5 Description of the device 6 Frontside 6 Backside 6 Installation 7 Set Up and Operation 7 Control Modes 7 Multiple RDM Splitters DMX control 7 Fixture Linkin...

Страница 3: ...ing Your shipment includes Showtec RDM Splitter Pro 4 Channel DMX Pro power cable 1 4 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this de...

Страница 4: ...device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check...

Страница 5: ...and the warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Improper installation can...

Страница 6: ...r phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perfor...

Страница 7: ...0 240V AC 50 60Hz 4 DMX RDM output channels Connections Pro power connector IN 3 pin 5 pin DMX IN 3 pin 5 pin DMX THROUGH 4 x 3 pin DMX RDM OUT 4 x 5 pin DMX RDM OUT Fuse 1A 250V Dimensions 482 x 135...

Страница 8: ...ge Do not attempt to operate a 120V specification product on 230V power or vice versa Connect the device to the main power supply Control Modes Multiple RDM Splitters DMX control 01 Fasten the distrib...

Страница 9: ...bling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your...

Страница 10: ...ication See the product specification label for details Troubleshooting No Light If the light effect does not operate properly refer servicing to a technician Suspect three potential problem areas as...

Страница 11: ...ections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the li...

Страница 12: ...nections Pro power connector IN 3 pin 5 pin DMX IN 3 pin 5 pin DMX THROUGH 4 x 3 pin DMX RDM OUT 4 x 5 pin DMX RDM OUT Housing Metal flame retardant plastic Fuse 1A 250V Dimensions 482 x 135 x 44 mm L...

Страница 13: ...12 Ordercode 50787 RDM Splitter Pro 4 Channel DMX Notes...

Страница 14: ...13 Ordercode 50787 RDM Splitter Pro 4 Channel DMX...

Страница 15: ...14 Ordercode 50787 RDM Splitter Pro 4 Channel DMX...

Страница 16: ...2017 Showtec...

Отзывы: