RDM Splitter Pro 4 Channel DMX 

 

 

Problem Probable 

cause(s) 

Solution 

One or more 

fixtures do not 

function at all 

No power to the fixture 

• 

Check if power is switched on and 

cables are plugged in 

Primary fuse blown 

• 

Replace fuse 

Fixtures reset 

correctly, but all 

respond 
erratically or not 

at all to the 

controller 

The controller is not connected. • 

Connect 

controller. 

 

3-pin/5-pin XLR Out of the 
controller does not match XLR Out 

of the first fixture on the link (i.e. 

signal is reversed) 

• 

Install a phase reversing cable 
between the controller and the 

first fixture on the link 

Fixtures reset 

correctly, but 
some respond 

erratically or not 

at all to the 
controller 

Poor data quality 

• 

Check data quality. If much lower 

than 100 percent, the problem 
may be a bad data link 

connection, poor quality or 

broken cables, missing termination 
plug, or a defective fixture 

disturbing the link 

Bad data link connection 

• 

Inspect connections and cables. 

Correct poor connections. Repair 
or replace damaged cables 

Data link not terminated with 120 
Ohm termination plug 

• 

Insert termination plug in output 
jack of the last fixture on the link 

Incorrect addressing of the fixtures  • 

Check address setting 

One of the fixtures is defective and 
disturbs data transmission on the 

link 

• 

Bypass one fixture at a time until 

normal operation is restored: 
unplug both connectors and 

connect them directly together. 

• 

Have the defective fixture 
serviced by a qualified technician  

3-pin/5-pin XLR Out on the fixtures 

does not match (pins 2 and 3 

reversed) 

• 

Install a phase-reversing cable 
between the fixtures or swap pin 2 

and 3 in the fixture that behaves 

erratically  

No light or 

LEDs/lamp cuts 

out intermittently 

Fixture is too hot 

• 

Allow the fixture to cool down 

• Clean 

the 

fan 

• 

Make sure air vents in control 

panel and the front lens are not 

blocked 

• 

Turn up the air conditioning 

LEDs/lamp damaged 

• 

Disconnect the fixture and return it 
to your dealer 

The power supply settings do not 
match local AC voltage and 

frequency 

• 

Disconnect fixture. Check settings 
and correct if necessary 

 

Содержание 50787

Страница 1: ...RDM Splitter Pro 4 Channel DMX V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50787 MANUAL ENGLISH...

Страница 2: ...ith the mains 4 Return Procedure 5 Claims 5 Description of the device 6 Frontside 6 Backside 6 Installation 7 Set Up and Operation 7 Control Modes 7 Multiple RDM Splitters DMX control 7 Fixture Linkin...

Страница 3: ...ing Your shipment includes Showtec RDM Splitter Pro 4 Channel DMX Pro power cable 1 4 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this de...

Страница 4: ...device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check...

Страница 5: ...and the warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Improper installation can...

Страница 6: ...r phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perfor...

Страница 7: ...0 240V AC 50 60Hz 4 DMX RDM output channels Connections Pro power connector IN 3 pin 5 pin DMX IN 3 pin 5 pin DMX THROUGH 4 x 3 pin DMX RDM OUT 4 x 5 pin DMX RDM OUT Fuse 1A 250V Dimensions 482 x 135...

Страница 8: ...ge Do not attempt to operate a 120V specification product on 230V power or vice versa Connect the device to the main power supply Control Modes Multiple RDM Splitters DMX control 01 Fasten the distrib...

Страница 9: ...bling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your...

Страница 10: ...ication See the product specification label for details Troubleshooting No Light If the light effect does not operate properly refer servicing to a technician Suspect three potential problem areas as...

Страница 11: ...ections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the li...

Страница 12: ...nections Pro power connector IN 3 pin 5 pin DMX IN 3 pin 5 pin DMX THROUGH 4 x 3 pin DMX RDM OUT 4 x 5 pin DMX RDM OUT Housing Metal flame retardant plastic Fuse 1A 250V Dimensions 482 x 135 x 44 mm L...

Страница 13: ...12 Ordercode 50787 RDM Splitter Pro 4 Channel DMX Notes...

Страница 14: ...13 Ordercode 50787 RDM Splitter Pro 4 Channel DMX...

Страница 15: ...14 Ordercode 50787 RDM Splitter Pro 4 Channel DMX...

Страница 16: ...2017 Showtec...

Отзывы: