OPERATING DETERMINATIONS 

• This device is not designed for permanent operation. Consistent operation breaks will ensure that the  
  device will serve you for a long time without defects.

 

• The minimum distance between light-output and the illuminated surface must be more than 0,5 meters. 
• The maximum ambient temperature 

t

a

 = 45°C must never be exceeded. 

• The relative humidity must not exceed 50 % with an ambient temperature of 45° C. 
• If this device is operated in any other way, than the one described in this manual, the product may  
   suffer damages and the

 

warranty becomes void.  

• Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 
 
You endanger your own safety and the safety of others! 
 
 

Rigging 

 

Please follow the European and national guidelines concerning rigging, trussing and all other 
safety issues. 

 

Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer !

 

 

Procedure: 

 

If the LED Tunnel Flower is lowered from the ceiling or high joists, professional trussing systems have 
to be used. 

 

Use a clamp to mount the LED Tunnel Flower, with the mounting-bracket, to the trussing system. 

 

The LED Tunnel Flower must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net 
or safety-cable. 

 

When rigging, derigging or servicing the device, always make sure, that the area below the 
installation place is blocked and staying in the area is forbidden. 

 

Improper installation can cause serious damage to people and property !

 

 

 

Connection with the mains

 

 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 
 

 International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN 

RED 

YELLOW/COPPER 

FASE 

BLUE 

BLACK 

SILVER 

NUL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 
Make sure that the device is always connected 

properly

 to the earth!  

 
 
 
 
 
 
 
 
 

Содержание 43031

Страница 1: ...LED Tunnel Flower ORDERCODE 43031...

Страница 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep yo...

Страница 3: ...eturn Procedure Claims Description Features and Overview Backside Installation Set Up and Operation Control Modes Built in Programs 1 7 All LEDs ON Automatic Sound Control Mode Master Slave Mode DMX M...

Страница 4: ...000 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may inc...

Страница 5: ...le voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can...

Страница 6: ...yourself Always let the installation be carried out by an authorized dealer Procedure If the LED Tunnel Flower is lowered from the ceiling or high joists professional trussing systems have to be used...

Страница 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Страница 8: ...lue 126 Beam angle 15 9 DMX channels Addressing by dipswitches Operation mode DMX512 Master Slave Sound controlled Built in Programs music controlled via built in microphone Fuse F2A 250V Overview 1 F...

Страница 9: ...sconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Control Modes There are 4 Modes 1 Built in Programs 1 7 All LEDs ON...

Страница 10: ...ter on all sides for air circulation 2 Use a 3 p XLR cable to connect the LED Tunnel Flower The pins 1 Earth 2 Signal 3 Signal 3 Link the units as shown in Fig 3 Connect a DMX signal cable from the fi...

Страница 11: ...cess to link the second third and fourth units 4 Set DMX dip switches as follows See Dip Switch setting page 10 LED Tunnel Flower Address Value DMX Dip Switches ON Unit 1 1 Unit 2 10 Unit 3 19 Unit 4...

Страница 12: ...Switches ON Unit 5 37 1 3 6 Switch Value 1 1 3 4 6 32 Total sum 37 Explanation Since each unit has 9 channels each address advances 9 values See Address Value above Once address values are determined...

Страница 13: ...11...

Страница 14: ...Function 132 255 Static Display Channel 4 Cluster 3 0 31 No Function 32 63 Mode 1 64 95 Mode 2 96 127 Mode 3 128 131 No Function 132 255 Static Display Channel 5 Cluster 4 0 31 No Function 32 63 Mode...

Страница 15: ...n the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are to be inspected by a skilled person once a year The following points have...

Страница 16: ...orrectly but all respond erratically or not at all to the controller The controller is not connected Connect controller 3 pin XLR Out of the controller does not match XLR Out of the first fixture on t...

Страница 17: ...peration mode DMX512 master slave Sound controlled auto trigger music controlled via built in microphone Fuse F26A 250V Dimensions 315 x 275 x 365 mm Weight 6 5 kg Minimum distance Minimum distance fr...

Страница 18: ......

Отзывы: