Troubleshooting 

 

No Light 

This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps 
below in sequence until a solution is found. Once the unit operates properly, do not carry out following 
steps.If the light effect does not operate properly, refer servicing to a technician. 
Response: Suspect three potential problem areas: the power supply, the lamp, the fuse. 

1.

 Power supply. Check that the unit is plugged into an appropriate power supply. 

2.

 The LEDs. Return the LED Tunnel Flower to your Showtec dealer. 

3.

 The fuse. Replace the fuse. See page 13 for replacing the fuse. 

 
 

No Response to DMX 

Response: Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card 
malfunction. 

1.

 Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power.  

    Try your DMX control again. 

2.

 Determine whether the controller or light effect is at fault. Does the controller operate properly with  

    Other DMX products ? If not, take the controller in for repair. If so, take the DMX cable and the light  
    effect to a qualified technician. 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 

 

 

Problem 

Probable cause(s) 

Remedy 

One or more 
fixtures are 
completely dead. 

No power to the fixture 

· Check that power is switched on  
  and cables are plugged in. 

Primary fuse blown. 

· Replace fuse. 

Fixtures reset 
correctly, but all 
respond 
erratically or not 
at all to the 
controller. 

The controller is not connected. 

· Connect controller. 

3-pin XLR Out of the controller 
does not match XLR Out of the first 
fixture on the link (i.e. signal is 
reversed). 

· Install a phase reversing cable  
  between the controller and the first  
  fixture on the link. 

 
 
 
 
 
 
 
 
 
 
Fixtures reset 
correctly, but 
some respond 
erratically or not 
at all to the 
controller. 

 
 
 
Poor data quality 

· Check data quality. If much lower  
  than 100 percent, the problem may  
  be a bad data link connection, poor   
  quality or broken cables, missing  
  termination plug, or a defective  
  fixture disturbing the link. 

 
Bad data link connection 

· Inspect connections and cables.  
  Correct poor connections. Repair or  
  replace damaged cables. 

Data link not terminated with 120 
Ohm termination plug. 

· Insert termination plug in output jack  
  of the last fixture on the link. 

Incorrect addressing of the fixtures.  · Check address setting. 
 
 
One of the fixtures is defective and 
disturbs data transmission on the 
link. 

· Bypass one fixture at a time until  
  normal operation is regained: unplug  
  both connectors and connect them  
  directly together. 
· Have the defective fixture serviced  
  by a qualified technician. 

 
3-pin XLR Out on the fixtures does 
not match (pins 2 and 3 reversed). 

· Install a phase-reversing cable 
  between the fixtures or swap pin 2  
  and 3 in the fixture, that behaves  
  erratically. 

 
No light 

The power supply settings do not 
match local AC voltage and 
frequency. 

· Disconnect fixture. Check settings  
  and correct if necessary. 

Содержание 43031

Страница 1: ...LED Tunnel Flower ORDERCODE 43031...

Страница 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep yo...

Страница 3: ...eturn Procedure Claims Description Features and Overview Backside Installation Set Up and Operation Control Modes Built in Programs 1 7 All LEDs ON Automatic Sound Control Mode Master Slave Mode DMX M...

Страница 4: ...000 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may inc...

Страница 5: ...le voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can...

Страница 6: ...yourself Always let the installation be carried out by an authorized dealer Procedure If the LED Tunnel Flower is lowered from the ceiling or high joists professional trussing systems have to be used...

Страница 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Страница 8: ...lue 126 Beam angle 15 9 DMX channels Addressing by dipswitches Operation mode DMX512 Master Slave Sound controlled Built in Programs music controlled via built in microphone Fuse F2A 250V Overview 1 F...

Страница 9: ...sconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Control Modes There are 4 Modes 1 Built in Programs 1 7 All LEDs ON...

Страница 10: ...ter on all sides for air circulation 2 Use a 3 p XLR cable to connect the LED Tunnel Flower The pins 1 Earth 2 Signal 3 Signal 3 Link the units as shown in Fig 3 Connect a DMX signal cable from the fi...

Страница 11: ...cess to link the second third and fourth units 4 Set DMX dip switches as follows See Dip Switch setting page 10 LED Tunnel Flower Address Value DMX Dip Switches ON Unit 1 1 Unit 2 10 Unit 3 19 Unit 4...

Страница 12: ...Switches ON Unit 5 37 1 3 6 Switch Value 1 1 3 4 6 32 Total sum 37 Explanation Since each unit has 9 channels each address advances 9 values See Address Value above Once address values are determined...

Страница 13: ...11...

Страница 14: ...Function 132 255 Static Display Channel 4 Cluster 3 0 31 No Function 32 63 Mode 1 64 95 Mode 2 96 127 Mode 3 128 131 No Function 132 255 Static Display Channel 5 Cluster 4 0 31 No Function 32 63 Mode...

Страница 15: ...n the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are to be inspected by a skilled person once a year The following points have...

Страница 16: ...orrectly but all respond erratically or not at all to the controller The controller is not connected Connect controller 3 pin XLR Out of the controller does not match XLR Out of the first fixture on t...

Страница 17: ...peration mode DMX512 master slave Sound controlled auto trigger music controlled via built in microphone Fuse F26A 250V Dimensions 315 x 275 x 365 mm Weight 6 5 kg Minimum distance Minimum distance fr...

Страница 18: ......

Отзывы: