background image

 

 

 

18 

 

  

 

 

Cameleon Flood 6 Q4 Tour 

Product code: 42682 

 

Control Panel 

 

A)

 

OLED display 

B)

 

DOWN button 

C)

 

UP button 

D)

 

SET button 

E)

 

MODE button 

Fig. 10   

 

Use the MODE button to exit the current submenu and to return to the Main Menu. 

 

Use the UP/DOWN buttons to navigate through the menus or to increase/decrease numeric values. 

 

Use the SET button to open the desired menu, to confirm your choice or to set the currently selected 
value. 

 

Start-up 

Upon start-up the display will briefly show its software version and current temperature. 

Note: 

If no button is touched after 30 seconds of inactivity, the display will show the start screen: Touch any 

button to return to the main menu. 

 

By default the display is locked. To access the main menu, you need to enter the password. Touch 
and hold the MODE and SET buttons for 3 seconds to unlock the display. See 6.6.6.5. Lock on page 27 
for more information. 

 
 
 
 

 

Содержание 42682

Страница 1: ...Cameleon Flood 6 Q4 Tour Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Product code 42682 USER MANUAL ENGLISH V1 ...

Страница 2: ...the device Non observance of the instructions in this user manual may result in serious injuries and damage of property 2021 Showtec All rights reserved No part of this document may be copied published or otherwise reproduced without the prior written consent of Highlite International Design and product specifications are subject to change without prior notice For the latest version of this docume...

Страница 3: ...11 Safety Instructions for Installation 11 Personal Protective Equipment 11 Installation Site Requirements 11 Rigging 12 Angle Adjustment 12 Connecting to Power Supply 13 Power Linking of Multiple Devices 13 5 Setup 14 Warnings and Precautions 14 Stand alone Setup 14 DMX Connection 14 DMX 512 Protocol 14 DMX Cables 15 Master Slave Setup 15 DMX Linking 16 DMX Addressing 16 6 Operation 17 Safety Ins...

Страница 4: ...s 29 Remote Control 30 Auto 32 Built in Programs 32 Color Presets 32 Strobe 32 Program Speed 33 Manual 33 7 Troubleshooting 34 8 Maintenance 35 Safety Instructions for Maintenance 35 Preventive Maintenance 35 Basic Cleaning Instructions 36 Corrective Maintenance 36 9 Deinstallation Transportation and Storage 37 Instructions for Deinstallation 37 Instructions for Transportation 37 Storage 37 10 Dis...

Страница 5: ... use is regarded as non intended and incorrect use Product Lifespan This device is not designed for permanent operation Disconnect the device from the electrical power supply when the device is not in operation This will reduce the wear and will improve the device s lifespan LEDs Lifespan The light output of the LEDs gradually decreases over time lumen depreciation High operating temperatures cont...

Страница 6: ...us situation which if not avoided may result in minor or moderate injury Attention Indicates important information for the correct operation and use of the product Important Read and observe the instructions in this document Electrical hazard Provides important information about the disposal of this product Symbols on the Information Label This product is provided with an information label The inf...

Страница 7: ...crews are tightly fastened Disconnect the device from electrical power supply before service and maintenance and when the device is not in use DANGER Electric shock caused by short circuit This device falls under IEC protection class I Make sure that the device is electrically connected to ground earth Connect the device only to a socket outlet with ground earth connection Do not cover the ground ...

Страница 8: ...aged to such an extent that their effectiveness is impaired for example by cracks or deep scratches Contact your Highlite International dealer for more information as servicing can be performed only by instructed or skilled persons If the device is dropped or struck disconnect the device from the electrical power supply immediately If the device is exposed to extreme temperature variations e g aft...

Страница 9: ...e used by ordinary persons Maintenance may be carried by ordinary persons Installation and service shall be carried out only by instructed or skilled persons Contact your Highlite International dealer for more information Instructed persons have been instructed and trained by a skilled person or are supervised by a skilled person for specific tasks and work activities associated with the installat...

Страница 10: ... equipped with 6 x 4 in 1 RGBW LEDs Front View 01 Infrared sensor 02 6 x 5 W RGBW LEDs 03 Mounting bracket Fig 02 Back View 04 IP65 rated 3 pin DMX signal connector IN 05 Safety eye 06 IP65 rated 3 pin DMX signal connector OUT 07 IP65 rated pro power True1 connector OUT 08 OLED display and touch buttons 09 IP65 rated pro power True1 connector IN Fig 03 ...

Страница 11: ... Master Slave DMX 512 RDM DMX channels 4 6 10 channels Control panel OLED display and touch buttons Connections Power connections IP65 rated pro power True1 connectors IN OUT Data connections IP65 rated 3 pin DMX connectors IN OUT Signal pinouts Pin 1 earth pin 2 pin 3 Construction Housing Die cast aluminum Color Black IP rating IP65 Cooling Convection Thermal Maximum ambient temperature ta 40 C M...

Страница 12: ...tions concerning rigging and trussing Personal Protective Equipment During installation and rigging wear personal protective equipment in compliance with the national and site specific regulations Installation Site Requirements The device can be used outdoors The device can be mounted to a truss or other rigging structure The minimum distance between the light output and the illuminated surface mu...

Страница 13: ...pporting structure as shown in Fig 05 Make sure that the device cannot move freely The use of a quick lock bracket is optional 02 Secure the device with a secondary suspension for example a safety cable Make sure that the secondary suspension can hold 10 times the weight of the device If possible the secondary suspension should be attached to a supporting structure independent of the primary suspe...

Страница 14: ...o that rain water cannot enter the device Make sure that the cable run is not too heavy A heavy cable run can cause damage to the connectors If the connectors are damaged their ingress protection IP can deteriorate Power Linking of Multiple Devices This device supports power linking Power can be relayed to another device via the power OUT connector Note that the input and the output connectors hav...

Страница 15: ...stand alone device For more information about the control modes refer to 6 2 Control Modes on page 17 DMX Connection DMX 512 Protocol You need a DMX serial data link to run light shows of one or more devices using a DMX 512 controller or to run synchronized shows of two or more devices set in a master slave control mode The Cameleon Flood 6 Q4 Tour has 3 pin DMX signal IN and OUT connectors The pi...

Страница 16: ...es correctly as shown in Fig 07 Fig 07 Master Slave Setup The Cameleon Flood 6 Q4 supports master slave control mode To connect multiple devices in a master slave setup follow the steps below 01 Connect the first device s DMX OUT connector to the second device s DMX IN connector 02 Repeat step 1 to connect all devices as shown in Fig 08 03 Connect a DMX terminator 120 Ω resistor to the DMX OUT con...

Страница 17: ...make sure that you set the DMX starting address of each device correctly The Cameleon Flood 6 Q4 Tour has 3 personalities 4 6 or 10 channels If you want to connect multiple devices on one data link and use them in 10 channel mode for example follow the steps below 01 Set the starting address of the 1st device on the data link to 1 001 02 Set the starting address of the 2nd device on the data link ...

Страница 18: ...Built in programs DMX 512 RDM 4 6 10 channels For more information about how to connect the devices refer to 5 Setup on pages 14 16 To operate the device manually as a stand alone device or in a master slave setup Adjust the colors in Manual menu See 6 6 2 Manual Mode on page 22 for more information To run the built in programs without a DMX controller 01 Select one of the 16 built in programs in ...

Страница 19: ...n the desired menu to confirm your choice or to set the currently selected value Start up Upon start up the display will briefly show its software version and current temperature Note If no button is touched after 30 seconds of inactivity the display will show the start screen Touch any button to return to the main menu By default the display is locked To access the main menu you need to enter the...

Страница 20: ...19 Cameleon Flood 6 Q4 Tour Product code 42682 Menu Overview ...

Страница 21: ...20 Cameleon Flood 6 Q4 Tour Product code 42682 ...

Страница 22: ...To access the main menu you need to enter the password Press and hold down the MODE and SET buttons for 3 seconds to unlock the display See 6 6 6 5 Lock on page 27 for more information DMX Settings In this menu you can set the DMX address and choose the desired DMX channel mode 01 While in the main menu touch the UP DOWN buttons to choose DMX 02 Touch the SET button to enter the menu The display w...

Страница 23: ...nels 10 channels Touch the SET button to confirm your choice Manual Mode In this menu you can manually set the desired colors 01 While in the main menu touch the UP DOWN buttons to choose MANUAL 02 Touch the SET button to enter the menu The display will show Touch the UP DOWN buttons to choose one of the 4 colors Red Green Blue and White Touch the SET button to enter the menu Touch the UP DOWN but...

Страница 24: ... to the previous screen 04 Touch the SET button to confirm your choice Program In this menu you can set the built in programs and color presets 01 While in the main menu touch the UP DOWN buttons to choose PROGRAM 02 Touch the SET button to enter the menu The display will show 03 Touch the UP DOWN buttons to choose MODE and touch the SET button to enter the menu The display will show 04 Touch the ...

Страница 25: ...to choose one of the 2 options SPEED STROBE 03 Touch the SET button to enter the desired menu 04 If you chose SPEED touch the UP DOWN buttons to set the built in program s speed The adjustment range is 1 100 from slow to fast Touch the SET button to save your settings 05 If you chose STROBE touch the UP DOWN buttons to set the strobe frequency The adjustment range is 0 99 from OFF to high frequenc...

Страница 26: ...ET button to enter the menu The display will show 03 Touch the UP DOWN buttons to choose one of the 6 submenus CURVES SELECT DIMMER SPEED DMX FAIL DMX SYNC LOCK FACTORY 04 Touch the SET button to enter the desired submenu Curves Select In this menu you can set the dimming curves 01 Touch the UP DOWN buttons to choose one of the 4 dimming curves 02 Touch the SET button to confirm your choice ...

Страница 27: ...device will black out the light output HOLD the device will use last properly received DMX signal ensuring undisrupted performance MANUAL the device will switch to Manual mode PROGRAM the device will run the built in programs 02 Touch the SET button to confirm your choice DMX Sync In this menu you can set the devices behavior while using multiple Cameleons 01 Touch the UP DOWN buttons to select ON...

Страница 28: ...conds OFF safety lock is inactive 02 Touch the SET button to confirm your choice Factory In this menu you can restore the default factory settings 01 Touch the UP DOWN buttons to select YES or NO 02 Touch the SET button to confirm your choice Information In this menu you can view the device s current software version temperature total lifetime and the UID device s RDM code 01 While in the main men...

Страница 29: ...00 W 150 070 076 Color 10 R 000 G 255 B 000 W 050 077 083 Color 11 R 000 G 255 B 000 W 000 084 090 Color 12 R 000 G 255 B 050 W 000 091 097 Color 13 R 000 G 255 B 150 W 000 098 104 Color 14 R 000 G 255 B 255 W 000 105 111 Color 15 R 000 G 255 B 255 W 075 112 118 Color 16 R 000 G 255 B 255 W 150 119 125 Color 17 R 000 G 100 B 255 W 255 126 132 Color 18 R 000 G 000 B 255 W 100 133 139 Color 19 R 000...

Страница 30: ...n Programs or Red Green Blue or White channels are open if you want to use Linear or Pulse Strobe channels Note Make sure that Color Presets and Built in Programs channels are closed if you want to use Red Green Blue and White channels Note Make sure that Built in Programs channel is closed if you want to use Color Presets channel Note Make sure that Built in Programs channel is open if you want t...

Страница 31: ...e by a transparent plastic foil Remove the plastic foil before using the remote control for the first time When replacing the battery make sure that the polarity is correct Incorrect polarity may damage the remote control You can control several devices at the same time with the remote control Make sure that you point the remote control to the infrared sensor 01 of the device or group of devices t...

Страница 32: ...s the following functions Fig 13 Note When you turn off the device the next time you turn it on it will continue to operate in the previously selected operation mode Button Function Description On Off Turns the LEDs on off Auto Activates Auto mode Program Activates Built in Programs mode No function Speed Activates program speed adjustment Strobe Activates strobe frequency adjustment Dimming Activ...

Страница 33: ...00 G 255 B 000 W 255 Color 18 Activates color 18 R 000 G 000 B 255 W 100 Color 6 Activates color 6 R 255 G 255 B 000 W 000 Color 31 Activates color 31 R 075 G 075 B 000 W 255 Auto Press the button to activate Auto mode The device will run its built in programs in a sequence Built in Programs Press the button to activate Built in Programs mode Press the and buttons to select one of the 16 built in ...

Страница 34: ...ll automatically switch to program 2 It is because the program speed function is available only in programs 2 16 The device searches for and activates the first following program that has the program speed function Manual Press the button to activate Manual mode Press the or button to choose one of the RGBW colors Press the and buttons to set the LED brightness of the selected color The adjustment...

Страница 35: ...l a phase reversing cable between the controller and the device The controller is defective Try using another controller The device responds erratically to DMX control Bad data link connection Examine connections and cables Correct poor connections Repair or replace damaged cables The data link is not terminated with a 120 Ω termination plug Insert a termination plug in the DMX OUT connector of th...

Страница 36: ...for at least 15 minutes before servicing or cleaning Preventive Maintenance Attention Before each use examine the device visually for any defects Make sure that All screws used for installing the device or parts of the device are tightly fastened and are not corroded The safety devices are not damaged There are no deformations on housings fixations and installation points The lens is not cracked o...

Страница 37: ...low 01 Disconnect the device from the electrical power supply 02 Allow the device to cool down for at least 15 minutes Remove the dust collected on the external surface with dry compressed air and a soft brush Clean the lens with a damp cloth Use a mild detergent solution Dry the lens carefully with a lint free cloth Clean the DMX and other connections with a damp cloth Attention Do not immerse th...

Страница 38: ...re This side up Fragile Storage Clean the device before storing Follow the cleaning instructions in chapter 8 2 1 Basic Cleaning Instructions on page 36 Store the device in the original packaging if possible 10 Disposal Correct disposal of this product Waste Electrical and Electronic Equipment This symbol on the product its packaging or documents indicates that the product shall not be treated as ...

Страница 39: ...38 Cameleon Flood 6 Q4 Tour Product code 42682 ...

Страница 40: ... 2021 Showtec ...