Wipe Out 3W 

Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to 
run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures the 
data link can support.  
 

Important: 

Fixtures on a serial data link must be daisy chained in one single line. To comply with the  
EIA-485 standard no more than 30 devices should be connected on one data link. 
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically 
isolated splitter may result in deterioration of the digital DMX signal. 

 

Maximum recommended DMX data link distance: 100 meters 
Maximum recommended number of Wipe Outs on a DMX data link: 30 fixtures 
Maximum recommended number of Wipe Outs on a power link: 8 fixtures @110V 
Maximum recommended number of Wipe Outs on a power link: 16 fixtures @240V 

 

Data Cabling 

To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX cables 
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable 
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic 
interference. 
 

DAP Audio DMX Data Cables 

 

DAP Audio Basic microphone cable for allround use. bal. XLR/M 3-pin > XLR/F 3-pin.  

Ordercode

 FL01150 (1,5 m), FL013 (3 m), FL016 (6 m), FL0110 (10 m), FL0115 (15 m), FL0120 (20 m). 

 

DAP Audio X-type data cable XLR/M 3-pin > XLR/F 3-pin. 

Ordercode

 FLX0175 (0,75 m), 

FLX01150 (1,5 m), FLX013 (3 m), FLX016 (6 m), FLX0110 (10 m). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®.

 Ordercode

 FL71150 (1,5 m), FL713 (3 m), FL716 (6 m), FL7110 (10 m). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®.

 Ordercode

 FL7275 (0,75 m), FL72150 (1,5 m), FL723 (3 m), FL726 (6 m), FL7210 (10 m). 

 

DAP Audio 110 Ohm cable with digital signal transmission. 

Ordercode

 FL0975 (0,75 m), 

FL09150 (1,5 m), FL093 (3 m), FL096 (6 m), FL0910 (10 m), FL0915 (15 m), FL0920 (20 m).   

 
 

 

Содержание 42567

Страница 1: ...Wipe Out 3W V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42567 MANUAL ENGLISH...

Страница 2: ...Outs Master Slave control 8 Multiple Wipe Outs DMX Control 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 Control Mode 11 DMX Addressing 11 Menu Overview 12 Main Menu Options 13 1 Auto Run Mod...

Страница 3: ...factor that leads to the acceleration of this decline Packaged in clusters LEDs exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all LEDs are us...

Страница 4: ...handle the power cord by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is n...

Страница 5: ...thers Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried...

Страница 6: ...a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your address 03 Your phone number 04 A brief descr...

Страница 7: ...power cable DMX control via standard DMX controller On Board LCD display for easy setup Control modes Auto Built in programs Sound controlled DMX 512 Master Slave Divided in 2 sections and equipped w...

Страница 8: ...pin DMX signal connector IN 03 IEC power connector 100 240V IN Fuse T2AL 250V 04 Ground earth connection 05 Power switch ON OFF 06 LCD display menu buttons 07 IEC power connector 100 240V OUT 08 3 pin...

Страница 9: ...de 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 When the Wipe Out is not connected with a DMX cable it functions as a stand alone device 0...

Страница 10: ...ices 05 Link the units as shown in Fig 03 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 0...

Страница 11: ...s on a power link 16 fixtures 240V Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct yo...

Страница 12: ...uld be 17 16 33 033 etc Please be sure that you do not have any overlapping channels in order to control each Wipe Out correctly If two or more Wipe Outs are addressed similarly they will work similar...

Страница 13: ...12 Ordercode 42567 Wipe Out 3W Menu Overview...

Страница 14: ...y shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN buttons to choose one of the 2 options LED Menu BAR Menu 04 Press the SETUP button to enter the desired menu 1 1 LED Menu 01 Pre...

Страница 15: ...ress the SETUP button to enter the flash frequency settings 15 Press the UP DOWN buttons to increase decrease the flash frequency The adjustment range is between from low to high frequency 1 2 Bar Men...

Страница 16: ...u you can set the DMX address 01 Press the MODE button until the display shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN buttons to choose one of the following 2 options DMX addr...

Страница 17: ...s voltage Product specification 04 When the display shows press the SETUP button to open the menu 05 Press the UP DOWN buttons to set the time after which the display turns off There are 5 options to...

Страница 18: ...Press the SETUP button to see the device s voltage 14 When the display shows press the SETUP button to enter the product specification menu 15 Press the UP DOWN buttons to toggle between the following...

Страница 19: ...adual adjustment from dark to brightest 0 100 Channel 6 Dimmer intensity LED2 0 255 Gradual adjustment from dark to brightest 0 100 Channel 7 Dimmer intensity LED3 0 255 Gradual adjustment from dark t...

Страница 20: ...D3 CH13 must be open 0 255 Gradual adjustment from dark to brightest 0 100 Channel 8 Dimmer intensity LED4 CH13 must be open 0 255 Gradual adjustment from dark to brightest 0 100 Channel 9 Dimmer inte...

Страница 21: ...d machine technical installations are to be inspected by an expert after every year in the course of an acceptance test The operator has to make sure that safety related and machine technical installa...

Страница 22: ...cing the fuse 04 If all of the above appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Wipe Out as this may damage the unit and the wa...

Страница 23: ...connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the...

Страница 24: ...ibilities DMX control via standard DMX controller On Board Display for easy setup Control Auto Built in programs Sound controlled DMX 512 Master Slave Quick lock mounting brackets included which makes...

Страница 25: ...24 Ordercode 42567 Wipe Out 3W Dimensions...

Страница 26: ...25 Ordercode 42567 Wipe Out 3W Notes...

Страница 27: ...26 Ordercode 42567 Wipe Out 3W...

Страница 28: ...2015 Showtec...

Отзывы: