31
Problem
Probable cause(s)
Remedy
One or more
fixtures are
completely dead.
No power to the fixture
· Check that power is switched on
and cables are plugged in.
Primary fuse blown.
· Replace fuse.
The flat cable inside the Matrix
maybe loose, due to wobbly
transportation
· Check if all cables are properly
connected, by gently pressing them
to the PCB boards.
Fixtures reset
correctly, but all
respond
erratically or not
at all to the
controller.
The controller is not connected.
· Connect controller.
3-pin XLR Out of the controller
does not match XLR Out of the first
fixture on the link (i.e. signal is
reversed).
· Install a phase reversing cable
between the controller and the first
fixture on the link.
Fixtures reset
correctly, but
some respond
erratically or not
at all to the
controller.
Poor data quality
· Check data quality. If much lower
than 100 percent, the problem may
be a bad data link connection, poor
quality or broken cables, missing
termination plug, or a defective
fixture disturbing the link.
Bad data link connection
· Inspect connections and cables.
Correct poor connections. Repair or
replace damaged cables.
Data link not terminated with 120
Ohm termination plug.
· Insert termination plug in output jack
of the last fixture on the link.
Incorrect addressing of the fixtures. · Check address setting.
One of the fixtures is defective and
disturbs data transmission on the
link.
· Bypass one fixture at a time until
normal operation is regained: unplug
both connectors and connect them
directly together.
· Have the defective fixture serviced
by a qualified technician.
3-pin XLR Out on the fixtures does
not match (pins 2 and 3 reversed).
· Install a phase-reversing cable
between the fixtures or swap pin 2
and 3 in the fixture, that behaves
erratically.
No light
The power supply settings do not
match local AC voltage and
frequency.
· Disconnect fixture. Check settings
and correct if necessary.
Lamp missing or blown
· Disconnect fixture and replace lamp.
Lamp cuts out
intermittently.
Fixture is too hot.
· Allow fixture to cool.
· Clean fan.
· Make sure air vents at control panel
and front lens are not blocked.
· Turn up the air conditioning.
The power supply settings do not
match local AC voltage and
frequency.
· Disconnect fixture. Check settings
and correct if necessary.
Содержание 30711 Matrix Blinder 5x5
Страница 20: ...18 Static Patterns...
Страница 28: ...26 Chase 225 Chase 226 Chase 227 Chase 228 Chase 229 Chase 230 Between 231 255 there are no chases...
Страница 35: ......