background image

 

14 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 

 
 
 
 
 
 
 
 

Problem 

Probable cause(s) 

Remedy 

 
One or more 
fixtures are 
completely dead. 

No power to the fixture 

• Check that power is switched on 

and cables are plugged in. 

Primary fuse blown. 

• Replace fuse. 
 

Fixtures reset 
correctly, but all 
respond 
erratically or not 
at all to the 
controller. 

The controller is not connected. 

• Connect controller.  

3-pin XLR Out of the controller 
does not match XLR Out of the first 
fixture on the link (i.e. signal is 
reversed). 

• Install a phase reversing cable 

between the controller and the first 
fixture on the link. 

 
 
 
 
 
 
 
 
 
 
Fixtures reset 
correctly, but 
some respond 
erratically or not 
at all to the 
controller. 

 
 
 
Poor data quality 

• Check data quality. If much lower 

than 100 percent, the problem may 
be a bad data link connection, poor 
quality or broken cables, missing 
termination plug, or a defective 
fixture disturbing the link. 

 
Bad data link connection 

• Inspect connections and cables. 

Correct poor connections. Repair or 
replace damaged cables.  

Data link not terminated with 120 
Ohm termination plug. 

• Insert termination plug in output jack 

of the last fixture on the link. 

Incorrect addressing of the fixtures.  • Check address setting.  
 

 

One of the fixtures is defective and 
disturbs data transmission on the 
link. 

• Bypass one fixture at a time until 

normal operation is regained: unplug 
both connectors and connect them 
directly together. 

• Have the defective fixture serviced 

by a qualified technician.  

 
3-pin XLR Out on the fixtures does 
not match (pins 2 and 3 reversed). 

• Install a phase-reversing cable 

between the fixtures or swap pin 2 
and 3 in the fixture, that behaves 
erratically.  

Shutter closes 
suddenly 

The color wheel has lost its index 
position and the fixture is resetting 
the effect. 

• Contact a technician for servicing 

the problem persists. 

 

 

 
No light or lamp 
cuts out 
intermittently 

Fixture is too hot. 

• Allow fixture to cool. 
• Clean fan. 
• Make sure air vents at control panel 

and front lens are not blocked. 

•  Turn up the air conditioning . 

 

LEDs damaged 

• Disconnect fixture and return to your 

dealer. 

The power supply settings do not 
match local AC voltage and 
frequency. 

• Disconnect fixture. Check settings 

and correct if necessary. 

 

Содержание 30628

Страница 1: ...LED Followspot 75W ORDERCODE 30628 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700 ...

Страница 2: ...ly on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showtec info You can get some of the best quality best priced products on the market from Showtec So next time turn to Showtec for more great ligh...

Страница 3: ...t Setup 7 Backside Followspot 75W 8 Installation 8 Set Up and Operation 8 Control Modes 8 One LED Followspot Manual Mode 8 Multiple LED Followspots DMX Control 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 Control Mode 11 DMX Addressing 11 Menu Overview 11 DMX Channels 12 3 Channels 12 Maintenance 12 Replacing a Fuse 13 Troubleshooting 13 No Light 13 No Response to DMX 13 Product Specifica...

Страница 4: ...s of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overall projection intensity Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual Before your initial start up please make sure that there is no d...

Страница 5: ...t Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can impact on the truss system The cable insert or the female part in the device must never be strained There must always be sufficient cable to the device Otherwise the cable...

Страница 6: ... Always let the installation be carried out by an authorized dealer Procedure If the LED Followspot 75W is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the LED Followspot 75W with the mounting bracket to the trussing system The LED Followspot 75W must never be fixed swinging freely in the room The installation must always be secured wit...

Страница 7: ... description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It is ...

Страница 8: ...nually controlled or by DMX 3 Channels Lumen 1600 Lux 1m 25000 Efficiency 21 lm W LED Quantity 1x CW 75W Driver current 19A Iris 2 100 manual Beam Angle 16 22 On Board Display for easy Set Up Options DMX512 Manual 3 DMX Channels Input Voltage 100 240VAC 50 60Hz Power consumption 121W max FO IP Rating IP 20 Housing Die cast Aluminium powder coat finish Connections IEC XLR 3 pin IN and OUT Cooling F...

Страница 9: ...plete Followspot Setup 5 6 7 8 9 Fig 2 5 DMX signal connector IN 6 DMX signal connector OUT 7 Stand Pole total setup height 1110 1440 mm 8 Torx bolts for mounting the followspot to the stand 9 Mounting Plate ...

Страница 10: ...e cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in always make sure that the power supply matches the product specification voltage Damages caused by non observance are not subject to warranty Control Modes There are 2 modes Manual Mode DMX...

Страница 11: ... 3 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 5 Supply electric power Plug electric mains power cords into each unit s IEC socket then plug the other end of the mains power cord into proper electric power supply sockets starting with the first unit Do not supply power before the whole ...

Страница 12: ...recommended DMX data link distance 100 meters Maximum recommended number of LED Followspots on a DMX data link 30 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality s...

Страница 13: ... be sure that you don t have any overlapping channels in order to control each LED Followspot correctly If two or more LED Followspots are addressed similarly they will work similarly For address settings please refer to the instructions under Addressing Controlling After having addressed all LED Followspot fixtures you may now start operating these via your lighting controller Note After switchin...

Страница 14: ... connections clean Disconnect electric power and then wipe the DMX and audio connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power The operator has to make sure that safety relating and machine technical installations are to be inspected by an expert after every year in the course of an acceptance test The operator has to make s...

Страница 15: ... refer servicing to a technician Response Suspect four potential problem areas as factory reset the power supply the LED the fuse 1 Power supply Check that the unit is plugged into an appropriate power supply 2 The LEDs Return the LED Followspot 75W to your Showtec dealer 3 The fuse Replace the fuse See page 13 for replacing the fuse 4 If all of the above appears to be O K plug the unit in again 5...

Страница 16: ...t terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until normal operation is regained unplug both connectors and connect them directly together Have the defective fixture se...

Страница 17: ...600 Lux 1m 25000 Efficiency 21 lm W LED Quantity 1x CW 75W Driver current 19A Iris 2 100 manual Beam Angle 16 22 On Board Display for easy Set Up Options DMX512 Manual 3 DMX Channels Input Voltage 100 240VAC 50 60Hz Power consumption 121W max FO IP Rating IP 20 Housing Die cast Aluminium powder coat finish Connections IEC XLR 3 pin IN and OUT Cooling Forced Cooling Fan Weight LED Followspot 75W 6 ...

Страница 18: ......

Отзывы: