- 6 -
Installation
When moving the machine body, use its hanging (ring) bolts and handle the body very
carefully without giving it impact. Never hang the body at one point. This work should be
undertaken only by qualified persons.
(The CFM-H40 machine must be hung by 4 points.)
As its installation, the machine should be fixed on a concrete floor with anchor bolts. Use liner
to regulate any gap between the machine and the floor. Use the base plate nut for leveling
work.
Keep enough room above the exhaust outlet of the machine’s roof so the machine may
display its normal suction power at all times. Put nothing on the outlet.
Electrical wiring
Only qualified persons should work on the
electrical wiring of the dust collector pursuant
to the Electrical Equipment Technical
Standards and the Internal Wiring Regulations.
Make sure of the machine’s power supply as
per its nameplate and use what is specified
therein. Operating the machine on a different
power supply could be very dangerous causing
an operation failure.
The breaker and earth leakage breaker of the power supply should be compatible with the
start-up current value.
Be sure to earth the power supply connection.
形 式
200V
50Hz
200V
60Hz
220V
60Hz
CFM-H10
6.1A
6.1A 5.6A
CFM-H20
8.5A 8.1A 7.5A
CFM-H30
15.1A 13.7A 12.9A
CFM-H40
22.6A 21.0A 20.0A