26.The mono MIC/LINE channels

 

      These are the channels from Channel1 to Channel4. You 
      can connect balanced, low impedance microphones  to the
      XLR socket. On the 1/4" phone jack you can connect either

      a microphone or a line level instrument. 

You shall never 

     connect an unbalanced microphone lt the XLR socket 
     if you do not want to damage both the Microphone and
     the Mixer. 

27.  Ch1, CH2, CH3 and inputs sensitivity and  XLR phantom  switch

   

      By turning the switch onto the "LINE" position the  

      CH1, Ch2, Ch3 input can be connected to an audio 

      source with high level signal output. By turning these  
      switches onto the MIC position, CH1, CH2, Ch3 input 
      can be connected to a dynamic microphone with low 
      impedance. By turning the switch onto the "Phantom" 

      position it connects phantom supply for  XLR pin2 and pin3

      of  CH1, CH2, Ch3, which is  necessary to operate condenser microphone

      which  requires  this type of external supply. It is recommended to use 
      this switch with the general volume set on minimum.

28.Line Out Bal/Unbal

      These terminals can be connected with other appliance, such as amplifier,

      recorder, etc. 

29.Power Amp Output

      These terminals allow connecting speakers.   

27

28

29

6

Total impedance: 4 ohms

100V

70V 

25V 

COM      4

G

    8

100V

70V 

25V 

COM      4

G

    8

Connecting the speakers with 25V output

0                              0                             0                  

100V

70V 

25V 

COM      4

G

    8

    25V

    25V

    25V

7

Total impedance: 8 ohms

Содержание MA-4075

Страница 1: ...d Taichung 401 TAIWAN Tel 886 4 22313737 Fax 886 4 22346757 http www show pa com e mail sekaku sekaku com All rights reserved to SEIKAKU All features and content might be changed without prior notice...

Страница 2: ...before operating this unit for the first time All rights reserved to SHOW All features and content might be changed without prior notice Any photocopy translation or reproduction of part of this manu...

Страница 3: ...External Connection Do not Remove any Covers Fuse To prevent fire and damage to the product use only the recommended fuse type as indicated in this manual Do not short circuit the fuse holder Before...

Страница 4: ...outlet seek advice from a qualified electrician Protect the power cord and plug from any physical stress to avoid risk of electric shock Do not place heavy objects on the power cord This could cause e...

Страница 5: ...nitor Volume Phone POWER VOLUME PL MA 4075 Multizone PA Mix Power Amplifier MON MON MON VOLUME VOLUME VOLUME MUTE CH 1 CH 2 CH 3 CH 4 CH 5 MUTE MUTE MUTE MUTE ZONE 1 ZONE 2 ZONE 3 ZONE 4 Z3 Z1 Z2 Z4 Z...

Страница 6: ...pas exposer a la pluie ou l humidite Ne pas enlever le couvercle Aucun reglage al interieur Pour reparation consulter une personne qualifiee RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION SHOCK HAZARD DO...

Страница 7: ...gnals appear again 23 Input AUX Paging The terminals input lets you connect to an auxiliary signal The input features Voice Priority function which overrides all other input signals once an auxiliary...

Страница 8: ...turning these switches onto the MIC position CH1 CH2 Ch3 input can be connected to a dynamic microphone with low impedance By turning the switch onto the Phantom position it connects phantom supply f...

Отзывы: