APPLICATIONS
Stereo Operation
D-150.2/D-300.2 can be used in the stereo mode as two separate 300/600 watt uni ts, each
capable of drivi ng lo ads d own t o 4 ohms. Each channel operates independently and has its own input
connectors,sensitivity level controls, signal indicator LEDs, automatic limiter, fault protection circuitry,
power amp, and speaker outputs. In the stereo mode, the signal smart switch must be set to the
stereo po sition.One application of the stereo mode uses one channel of the amplifier for the left
house speakers and the other channel for the right. The mixing board channels can be p anned lef t
or right according to the position of the instruments on the stage. This approach provides a more
accurate reproducti on of the live performance.
110-120V
110-120V
220-240V
220-240V
8
The two internal power amplifiers(CH1 and CH2) can be bridged t ogether to f orm a single , higher
powered amp. This is especially useful when using the amplifier to power a subwoofer. In the mon o
mode, the amplifier uses the channel 1 input jacks and sensitivity control(channel 2's are disabled).
When operation in this mode, each channel is independently protected. The signal smart switch must
be set to the bridge position and the minimum speaker load impedance must be 8 ohms.
Mono Bridge Operation