FEATURES AND SPECIFICATIONS (continued)

SETUP

Mild steel: 

1/4" 

Sever: 

1/2"

Power Supply / Phases (V-Ph) 

 

115/230V - 1 +/- 15%

Rated input Power (KVA)

 

5.5-230V

Rated Output Current

 

20-30A

Duty Cycle @ 104ºF 

 

35% @30A - 230V

Efficiency 

 

85%

Open Circuit Voltage 

 

96V

Protection Class 

 

IP21S

Cutting Capacity*

                Rated: 

1/4" (6.4 mm)

                Sever: 

 

1/2" (12.7 mm)

Air Supply: 

 

Clean, dry, oil-free

 

compressed air

Recommended Input 

6.0 SCFM @ 75 PSI

Pressure/Flow

Size (Inches) 

 

20" x 12" x 16"

Weight (Pounds) 

20.25 

Compliant to 

CAN/CSA E60974-1

*mild steel 

TECHNICAL DATA

FEATURES

CUTTING CAPACITY

•  POWERFUL AND RELIABLE IGBT INVERTER 

TECHNOLOGY DELIVERS 30 AMPS AT A 35% 

DUTY CYCLE

•  DUAL VOLTAGE-SENSING TECHNOLOGY

 (115V 

OR 230V)

 LETS YOU PLUG INTO ANY COMMON 

POWER SUPPLY WITH INCLUDED ADAPTER

•  CUTS MILD STEEL, STAINLESS, BRASS, 

ALUMINUM AND OTHER CONDUCTIVE 

MATERIALS

•  LOW FREQUENCY, PILOT ARC SYSTEM FOR 

INSTANT STARTS AND EASE OF USE WHEN 

CUTTING RUSTY MATERIAL AND WILL 

NOT INTERFERE WITH OTHER ELECTRICAL 

SYSTEMS INCLUDING TELEPHONE OR 

COMPUTER

•  SELF-RESETTING THERMAL OVERLOAD 

PROTECTION WITH INDICATOR LIGHT 

AUTOMATICALLY SHUTS OFF TO AVOID 

OVERHEATING

•  ADJUSTABLE AIR FILTER/ PRESSURE 

REGULATOR

•  LIGHTWEIGHT AND PORTABLE LESS THAN 

21 POUNDS!

• FAN COOLED

BUILT TO GET THE JOB DONE

1. 12 ft. TRF45 Plasma Torch

      (Direct Connect)

2. 115/230V Power Adapter

3. Work Clamp

4. Work Clamp Connection

5. Air Pressure Gauge

6. Current Adjustment

7. Power Light

8. Overload Light

9. Cutting Operation Light

10. Trigger Latch Operation

11. Cutting Mode Switch

12. Air Regulator

13. Control PCB

14. Magnetic Valve

15. Power Switch

16. Input Power Cable

12

14

13

15

16

FEATURES AND SPECIFICATIONS

BUILT TO GET THE JOB DONE

(1) Connect the earth lead to the output terminal of the machine and tighten.

(2) Connect the air supply to the air connection located at the rear of the machine.

Turn on the air supply

(3)

located at the rear of the machine.

(4) Select 2T / 4T operation

Operating procedure using the 2T / 4T Function with Plasma torch.

Set torch operation 2T / 4T.

When 2T operation is selected press trigger Arc starts, release trigger Arc stops.

When 4T operation is selected press and release trigger Arc starts,

press and release trigger Arc stops.

(5) Set amperage dial.

(3)  Connect the machine to the 

correct power supply and switch on 

located at the rear of the machine..

(2) Connect the air supply to the air 

connection located at the rear of the 

machine. Turn on the air supply.

(4) select 2T or 4T torch control .

(1) Connect the earth lead to the 

output terminal of the machine and

tighten.

(5)  Set the amperage dial

Содержание 41199

Страница 1: ...s in materials or workmanship or damages result from repairs or alterations which have been made or attempted by others or the unauthorized use of nonconforming parts this damage is due to abuse improper maintenance neglect or accident or the damage is due to use of the product after partial failure or use with improper accessories Seller will not be liable for labor charges loss or damage resulti...

Страница 2: ...TENTS Introduction Safety Cautions Air Plasma Cutting Technology Technical Data Features and Specifications Set Up and Operating Procedure Plasma Cutting Procedure Replacement Parts Techniques 14 15 Notes Warranty BUILT TO GET THE JOB DONE ...

Страница 3: ...5249 13 95814 telephone 916 445 6900 California Proposition 65 website www oehha ca gov prop65 html American National Standards Institute ANSI Product Safety Signs And Labels ANSI Z535 4 available from ANSI 25 West 43rd Street New York NY 10036 telephone 212 642 4900 web site www ansi org SAFETY IMPORTANT BEFORE INSTALLING OPERATING OR CARRYING OUT MAINTENANCE ON THE PLASMA CUTTER READ THE CONTENT...

Страница 4: ... and gas generated whilst welding or cutting keep your head out of the fumes Keep the working area well ventilated use fume extraction or ventilation to remove welding fumes and gases Cutting fumes and gases can displace air and lower the oxygen level causing injury or death Be sure the breathing air is safe Do not cut in locations near de greasing cleaning or spraying operations The heat and rays...

Страница 5: ...doing a lot of cutting cutting thick plate same air consumption but slower cut speeds longer cut time then choose a compressor at 1 5 to 2 times the plasma system requirement Technique Tips Starting a cut Hand torch cutting technique Good air quality is essential to quality plasma cutting and consumable life span Compressors take in air at atmospheric pressure and increase the pressure and store i...

Страница 6: ...output terminals while the machine is in operation An electric shock may possibly occur MAINTENANCE Exposure to extremely dusty damp or corrosive air is damaging to the welding machine In order to prevent any possible failure or fault of this welding equipment clean the dust at regular intervals with clean and dry compressed air of required pressure Please note that lack of maintenance can result ...

Страница 7: ...available and thus plasma does not require fuel gas and compressed oxygen for operation Plasma cutting is typically easier for the novice to master and on thinner materials plasma cutting is much faster than oxy fuel cutting However for heavy sections of steel 1 and greater oxy fuel is still preferred since oxy fuel is typi cally faster and for heavier plate applications high powered plasma machin...

Страница 8: ...HTWEIGHT AND PORTABLE LESS THAN 21 POUNDS FAN COOLED BUILT TO GET THE JOB DONE 1 12 ft TRF45 Plasma Torch Direct Connect 2 115 230V Power Adapter 3 Work Clamp 4 Work Clamp Connection 5 Air Pressure Gauge 6 Current Adjustment 7 Power Light 8 Overload Light 9 Cutting Operation Light 10 Trigger Latch Operation 11 Cutting Mode Switch 12 Air Regulator 13 Control PCB 14 Magnetic Valve 15 Power Switch 16...