background image

4

Using the occlusal plane as a 

reference plane
When  positioning  upper  cast  and 

wax  occlusal  rim  with  the  occlusal 

plane as a reference plane, the ideal 

arch for the upper anterior teeth and 

the median line should be matched 

with upper labial side and median of 

the wax rim.
Based on one of the reference lines 

selected  among  S,  M  and  L  for 

posterior  wax  rim,  the  buccal  side 

of wax rim should be symmetrically 

positioned. Check the position of the 

wax rim from above and behind.

5

Positioning the wax rim based  

on the mean value of natural 

 

head posture
When  applying  the  mean  value  of 

natural  head  posture  to  position 

the  wax  rim,  the  occlusal  plate  is 

used.  In this case, beading wax is 

used to raise the distobuccal cusps 

of  the  upper  second  molars  about 

7mm higher than the occlusal plate, 

to  make  the  occlusal  plane  angle 

approximately 10 degrees.

6

When  the  median  lines  of  the 

articulator  and the upper  cast have 

been  matched  to  mount  the  cast, 

arrangement  of  the  upper  central 

incisors  can  be  checked  with  the 

incisal indicator.  (Prior to checking, 

the  incisal  indicator  should  be 

pointed in the median direction using 

the occlusal plate).

14

Содержание Pro Arch IIG

Страница 1: ...Pro Arch IIG SEMI ADJUSTABLE ARTICULATOR Instructions for Use...

Страница 2: ...TABLE OF CONTENTS Introduction Features Identification of Parts Operating Precedure Direction for Use Caution Specifications 2 3 5 6 7 20 21 Shofu Pro Arch IIG SEMI ADJUSTABLE ARTICULATOR 1...

Страница 3: ...ively The sagittal or lateral incisal path angle can be changed using different incisal tables The twin plate mechanism at the condylar guidance combines the benefits of both box and slot type When fa...

Страница 4: ...ondylar path angle is easily adjustable using anterior check bite record This arcon type articulator is similar to the human jaw structure which provides easy comprehension of jaw movement and excelle...

Страница 5: ...tly Upper and lower jaws are easily separated when the Centric Lock Levers are released Upper jaw can be opened up to 120 and stays in place for increased access and added convenience Incisal Indicato...

Страница 6: ...ator Screw Incisal Pin Incisal Indicator Incisal Pin Screw 1 2 3 4 5 6 7 10 11 12 13 14 15 16 8 9 Incisal Table 10 Incisal Table Screw Sagittal Condylar Path Adjuster Sagittal Condylar Path Lock Lever...

Страница 7: ...Table Take out the Incisal Table Screw and replace the table with the desired one 0 10 option 5 15 2 Twin Plate mechanism Loosen the Guide Plate Screw to detach the Condylar Path Downward Guide Plate...

Страница 8: ...e lock press the lever down firmly until the shaft snaps Ensure that both Centric Locks are being released when moving forward or laterally Releasing only one of the locks provides inaccurate reproduc...

Страница 9: ...at the Incisal Pin scale is set to 0 red line A notch in the Incisal Pin helps the pin to stop precisely at 0 every time to ensure accurate occlusal position 2 Set an angle of sagittal condylar path t...

Страница 10: ...us and anterior reference point should be 23mm below the inner canthus or 45 mm above the maxillary incisal edge When using the axis orbital plane remove the earpieces Posterior reference point should...

Страница 11: ...crew Earpiece Bite Fork for edentulous jaw Bite Fork for dentulous jaw optional Bite Fork Screw 1 2 3 4 5 6 7 8 9 10 11 12 Bite Fork Clamp Anterior Reference Pin Anterior Reference Pin Clamp Anterior...

Страница 12: ...tip of the anterior reference pin to point 23mm below the inner canthus or 45mm above the maxillary incisal edge This enables transfer of natural head posture to the articulator 1 1 Registration with...

Страница 13: ...ace Bow place the tip of the anterior reference pin to come in contact with the under surface of the Reference Indicator Then adjust the Elevating Rod and secure it with the Elevating Rod Screw 3 2 Ho...

Страница 14: ...of the cuspids and the center of the first molars are indicated 3 a Ideal arch for the upper anterior teeth b Maxillary anterior incisal edge c Cuspids d Center of the first molars e Median line f Lin...

Страница 15: ...behind 5 Positioning the wax rim based on the mean value of natural head posture When applying the mean value of natural head posture to position the wax rim the occlusal plate is used In this case be...

Страница 16: ...aster at the undercut of the Cast Plate 2 Mounting the lower cast STEP 4 Fasten the Centric Lock Lever and tuen the articulator upside down then position the lower cast 1 Double investing technique is...

Страница 17: ...ontact with the Incisal Table Take patient s anterior bite registration with the mandible moved forward by 4 to 5mm Condylar path adjustment 2 Turn the articulator upside down for condylar path adjust...

Страница 18: ...lock both sides of Sagittal Condylar Path Lock Levers Set the sagittal condylar path angle to a negative value of approx 20 4 Releasing the Incisal Pin 5 Loosen the Incisal Pin Screw and lower the Inc...

Страница 19: ...contact with each other To minimize deviation use bite registration and hold the lower cast down to stabilize it 6 2 Attaching Condylar Path Downward Guide Plates 7 After adjusting the condylar path...

Страница 20: ...Incisal Table can be fabricated Place self cured resin such as tray resin on the 0 Incisal Table with a sheet of polyethylene film placed between upper and lower casts move the articulator forward an...

Страница 21: ...ide condylar ball coming in contact with the balancing side lateral condylar guidance 2 When the articulator is open with the Centric Lock Levers released and Condylar Path Downward Guide Plates Twin...

Страница 22: ...s Distance between upper and lower jaws Maximum opening angle Condylar Guidance Structure Angle of sagittal condylar path Angle of lateral condylar path Incisal Table Incisal Pin Mounting removal of c...

Страница 23: ...ates for IG II III EG OPTIONAL ACCESSORIES Gear type Cast Support with Occlusal Plate Handy Cast Support MSMP Single MSMP Double Pro Arch Split Cast Plates Steel Plates 10 plates Incisal Tables 5 Inci...

Страница 24: ...and Anterior Reference Pin Bite Fork for dentulous jaw optional Mounting Rings Incisal Table 0 OPEN STOCK ITEMS Incisal Table 10 SHOFU DENTAL ASIA PACIFIC PTE LTD 10 Science Park Road 03 12 The Alpha...

Отзывы: