To guarantee data integrity, the SpotBot has a batteries preservation feature that will turn
off the radio at 25% battery life but will still record the events in the unit (please refer to
chapter 7 for more information). At 15% battery, the unit will stop the trip but the data will
remain stored in the unit.
Modulus takes the X, Y and Z directional impacts into consideration and summarizes the
combined result of all 3 impacts.
Modulus =
Bellow the tab you can find a graph of impacts over time with X,Y,Z
and Modulus, representing the G levels of all the alarms issued by the
SpotBot. X,Y and Z axes directions can be found in the front label of
the unit:
Hovering the cursor over the bars in the
chart will allow you to see the individual
values for each impact over time.
This is true for all the graphs represented
on the web page.