background image

WIRING/CONNECTION DIAGRAMS

PATTERN TABLE

TROUBLESHOOTING

DIAGRAM (1):

ON/OFF and Low Power using two toggle

switches. Choose flash pattern from chart.

Selecting a flash pattern:

In the table below, find the desired

flash pattern. Connect the wires marked

to the

'load' side of the ON/OFF switch.

Example: To use pattern #8 (Quad Flash, All Heads), connect

the YELLOW, GREEN and BLUE wires to POWER.

POWER

Remove the remaining

wires, or connect them to Ground.

Remove the remaining wires, or connect them to Ground.

-

-

DIAGRAM (2):

ON/OFF and Low Power using one DPDT

rocker switch. Choose flash pattern from chart.

DIAGRAM (3):

Selective switching of strobe head pairs. Low

Power selection. Choose flash pattern from chart.

Blown Fuse

Erratic behavior (and/or) shutdown

: The 21.7690 will blow a fuse if the input

voltage is reversed. If this happens, first locate the wiring

fault, then replace the fuse with one of the same rating.

: The 21.7690 will

shut down if there is a short circuit condition on any one of

the strobe heads. If the electrical conductors connecting

the power supply to the strobe heads are exposed to water

a short circuit will result. The first sign is intermittent

operation, followed by complete shutdown of the strobe

system. To find the short circuit, unplug all strobe head

cables from the 21.7690. Test

cable/head at a time

until the problem is found.

one

WIRED TO +12/24V

FLASH PATTERN

NONE

Quad Flash

ORANGE

Mega Flash

WHITE

Quintpule Flash

WHITE + ORANGE

Double Flash

WIRED TO +12/24V

FLASH PATTERN

NONE

Quad Flash

ORANGE

Mega Flash

WHITE

Quintpule Flash

WHITE + ORANGE

Double Flash

WIRED TO +12/24V

FLASH PATTERN

NONE

Quad Flash

ORANGE

Mega Flash

WHITE

Quintpule Flash

WHITE + ORANGE

Double Flash

PATTERN

WHITE ORANGE YELLOW GREEN

BLUE

FUNCTION

1

SHUTDOWN

2

POWER

Quad Flash, 1 Alt 2

3

POWER

Quad Flash, 3 Alt 4

4

POWER POWER

Quad Flash, 1+3 Alt 2+4

5

POWER

Quad Flash, 5 Alt 6

6

POWER

POWER

Quad Flash, 1+5 Alt 2+6

7

POWER POWER

Quad Flash, 3+5 Alt 4+6

8

POWER POWER POWER

Quad Flash, 1+3+5 Alt2+ 4+6

9

POWER

SHUTDOWN

10

POWER

POWER

Mega Flash, 1 Alt 2

11

POWER

POWER

Mega Flash, 3 Alt 4

12

POWER

POWER POWER

Mega Flash, 1+3 Alt 2+4

13

POWER POWER

Mega Flash, 5 Alt 6

14

POWER POWER

POWER

Mega Flash, 1+5 Alt 2+6

15

POWER POWER POWER

Mega Flash, 3+5 Alt 4+6

16

POWER POWER POWER POWER

Mega Flash, 1+3+5 Alt2+ 4+6

17

POWER

SHUTDOWN

18

POWER

POWER

Quintuple Flash, 1 Alt 2

19

POWER

POWER

Quintuple Flash, 3 Alt 4

20

POWER

POWER POWER

Quintuple Flash, 1+3 Alt 2+4

21

POWER

POWER

Quintuple Flash, 5 Alt 6

22

POWER

POWER

POWER

Quintuple Flash, 1+5 Alt 2+6

23

POWER

POWER POWER

Quintuple Flash, 3+5 Alt 4+6

24

POWER

POWER POWER POWER

Quintuple Flash, 1+3+5 Alt2+ 4+6

25

POWER POWER

SHUTDOWN

26

POWER POWER

POWER

Double Flash, 1 Alt 2

27

POWER POWER

POWER

Double Flash, 3 Alt 4

28

POWER POWER

POWER POWER

Double Flash, 1+3 Alt 2+4

29

POWER POWER POWER

Double Flash, 5 Alt 6

30

POWER POWER POWER

POWER

Double Flash, 1+5 Alt 2+6

31

POWER POWER POWER POWER

Double Flash, 3+5 Alt 4+6

32

POWER POWER POWER POWER POWER

Double Flash, 1+3+5 Alt2+ 4+6

Alt = 'Alternates with'

ACCESSORIES

The following accessories are available to make the

installation of the 21.7690 power supply even easier:

A fully assembled switch panel which provides full

selection of all flash patterns as well as On/Off and Low

Power control.

ROTARY SWITCH PANEL

All panels are pre-wired with 15'(standard) of cabling.

INSTALL- 21.7690.CDR

Unused wires should either be removed, or connected to Ground.

-

Choose flash pattern

with Orange and White wires.

15

SPST

SPST

1

2

3

BATTERY -

GND, vehicle

chassis.

RED

YELLOW

GREEN

BLUE

BLAC

K

VIOLET

NO CONNECTION

NO CONNECTION

LOW POWER

SWITCH

ON / OFF

SWITCH

POWER HARNESS

CONTROL HARNESS

Toggle switches:

General purpose Single

Pole Single Throw.

Current through switch is

less than 1 amp.

ORANGE

B

OR CONSTANT

POWER CIRCUIT

15

1

2

3

BATTERY -

GND, vehicle

chassis.

RED

BLACK

VIOLET

NO CONNECTION

POWER HARNESS

Rocker Switch:

General purpose Double

Pole Double Throw.

Current through switch is

less than 1 amp.

CONTROL HARNESS

YELLOW

GREEN

BLUE

ORANGE

WHITE

Choose flash pattern

with Orange and White wires.

Unused wires should either be removed, or connected to Ground.

-

B

OR CONSTANT

POWER CIRCUIT

15

SPST

S

P

S

T

S

P

S

T

S

P

S

T

1

2

3

BATTERY -

GND, vehicle

chassis.

RED

YELLOW

GREEN

BLUE

BLACK

VIOLET

NO CONNECTION

NO CONNECTION

LOW POWER

SWITCH

HEADS 3 & 4

ON / OFF

SWITCH

HEADS 5 & 6

ON / OFF

SWITCH

HEADS 1 & 2

ON / OFF

SWITCH

POWER HARNESS

CONTROL HARNESS

Toggle switches:

General purpose Single

Pole Single Throw.

Current through switch is

less than 1 amp.

ORANGE

Unused wires should either be

removed, or connected to Ground.

-

Choose flash pattern

with Orange and White wires.

B

OR CONSTANT

POWER CIRCUIT

WHITE

Отзывы: