1. Remove the carton and log wrap.
2. Remove all protective packaging applied to heater for
shipment.
3. Make sure your logset includes one hardware packet.
4. Check heater for any shipping damage. If heater is
damaged, call SHM International at (800) 229-5647
for replacement parts before returning to dealer.
UNPACKING
PRODUCT FEATURES
AIR FOR COMBUSTION
AND VENTILATION
Today’s homes are built more energy efficient than ever.New
materials, increasedinsulation,andnewconstruction methods
help reduce heat loss in homes. Home owners weather strip
and caulk around windows and doors to keep the cold air out
and the warm air in. During heating months, home owners
want their homes as airtight as possible.
While it is good to make your home energy
your
home needs to breathe. Fresh air must enter your home. All
fuel-burning appliances need fresh air for proper combus-
tion and ventilation.
Exhaust fans, replaces, clothes dryers, and fuel burning ap-
pliances draw air from the house to operate. You must provide
adequate fresh air for these appliances. This will insure proper
venting of vented fuel-burning appliances.
SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing
(ODS) safety shutoff system. The ODS/pilot is a required
feature for vent-free room heaters. The ODS/pilot shuts off
the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system requires no
matches, batteries or other sources to light heater.
THERMOSTATIC HEAT CONTROL
Thermostat-controlled models have a thermostat sensing
bulb and a control valve. The thermostat will automatically
modulate the heat output to maintain a consistent room
temperature. This results in greater heater comfort. This
can also result in lower gas bills.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from National Fuel Gas Code
ANSI Z223.1/NFPA 54,Section 5.3, Air for Combustion
and Ventilation.
All spaces in homes fall into one of the following
1. Unusually Tight Construction
2.
The information on pages 4 through 6 will help you classify
your space and provide adequate ventilation.
WARNING: This heater shall not be
installed in a room or space unless the
required volume of indoor combustion air
is provided by the method described in
the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, the International Fuel Gas Code,
or applicable local codes.
Read the following instructions to insure
proper fresh air for this and other fuel-
burning appliances in your home.
QUALIFIED
INSTALLATION AGENCY
Installation and replacement of gas piping, gas utiliza-
tion equipment or accessories and repair and servicing of
equipment shall be performed only by a
agency.
The term
agency” means any individual,
corporation, or company that either in person or through a
A. Installation, testing or replacements of gas piping or
B. Connection, installation, testing, repair or servicing
of equipment that is experienced in such work; that
is familiar with all precautions required; and that has
complied with all requirement of the authority having
jurisdiction.
This heater shall not be installed in a confined space or unusually tight construction
unless provisions are provided for adequate combustion and ventilation air.
Содержание IVFMV18LP
Страница 11: ...Figure 7 Log Placement Savannah Oak 18 11 ...
Страница 12: ...Figure 8 Log Placement Savannah Oak 24 and 30 ...
Страница 13: ...Log Placement CVO 18 24 30 MV 18 24 VFM And OVM21 13 Figure 9 Log Placement CVO MV and OVM ...
Страница 20: ... See Fig 21 See Fig 22 Figure 22 Pilot Inlet Air Hole 19 ...
Страница 21: ...19 19 19 19 19 19 18 ...
Страница 22: ...22 ...
Страница 26: ...NOTES ...
Страница 27: ...NOTES ...