background image

No.

Fuel is leaking

1-2

At the time of plugging into the power
supply

3-4

At the time of turning on operation switch

5

About 3 seconds after turning on
operation switch

6

About 5 seconds after turning on
operation switch

7

At the time of changing to low combustion

8

No lamp is lit

9-18

Only operation lamp is lit, but heater does
not start

19-21

Overheat lamp is lit (Overheat protection
is working)

22-24

Tip-over lamp is lit (Tip-over switch is
working)

25-27

Overvoltage lamp is lit (Overvoltage
detection is working)

28-29

Overheat, tip-over and overvoltage lamp is
lit (Abnormal fan speed detection is
working)

30-35

Overheat, tip-over and overvoltage lamp is
lit (Abnormal fan speed detection is
working)

36-37

Electrode is not sparking

38-41

Fuel pump doesn't turn on (no vibration of
fuel pump)

42-46

Fuel pump is idling with clicking sound

47-48

Fuel is not sprayed normally from the
nozzle

49-55

Misfire lamp is lit within about 15 seconds
after switching on

56-62

Overheat lamp blinks during operation (in
any time)

63

Tip-over lamp blinks during operation (in
any time)

64-65

Overvoltage lamp lights during operation
(Low voltage detection is working)

66-67

Combustion is not stable

68

Smoke is continuous for about 3 minutes
(or heater produces WHITE smoke)

69-70

Heater produces BLACK smoke

71

Heater is using in high altitude

72

Smell of fuel comes out

73-75

76

Heater is using in high altitude

77

Changeover switch doesn't work

78-81

Internal thermostat doesn't work
(Heater doesn't stop operation at
preset temperature)

82-87

Combustion stops during the
operation

The heater does not ignite

Smoke comes out

Flame bounces out from the disk

Heater cannot start up

(heater does not operate at all with

switching on)

Troubleshooting for VAL6 EPX1/EPX5

Phenomenon

Fuse blows out

Содержание VAL6 EPX Series

Страница 1: ...VAL6 EPX Maintenance Manual ...

Страница 2: ...1 Names of components ...

Страница 3: ... Burner Control for EP6JA 2 Specifications 3 Wiring Diagram Wiring Diagram 0 75gal 60 H for H lot 0 85gal 60 H ...

Страница 4: ...on delay Fuel pre heater Plug IN Switch ON 2sec 10sec 10sec 200sec Fuel Pump pump delay post ignition post purge within 4 Sequence Time Chart Ignition Switch OFF Flame Monitor Operation Switch Fan Motor Igniter 5 ...

Страница 5: ...ilted lamp will blink Remedy Turn away form the direct sunlight Tighten all fittings and repeat start operation Replace a Nozzle or filter element Status Timing Possible causes During the operation During the operation Nozzle or filter element is clogged At the start of the operation The heater stays on slope Remove the causes of overheat Replace a nozzle or filter During the operation Power suppl...

Страница 6: ... the voltage of power source Operation is normal but the low voltage lamp is lit Less than 90 of standard voltage is detected Check the voltage of power source Voltage depression Replace a fan motor Misfire 5 times in a row Description When the heater does not ignite with five 5 consecutive tries four 4 lamps will blink Loose fitting in fuel line Start procedure is fail with five 5 consecutive tri...

Страница 7: ...andard Voltage input board Black Black fine Transformer AC 120V CN 10 CN 15 AC 230V AC 15V Solenoid pump CN 14 Ignition transformer AC 120V AC 230V approx 380Ω Chart1 Chart2 Fan motor CN 15 CN12 CN 10 0Ω CN 16 1 2 PIN 19 5kΩ 24kΩ Ω under DC1 2V approx DC5V 2kΩ 1kΩ 8 9kΩ approx a few MΩ Condition Resistance White White Red Red Ω 0Ω Ω 0Ω Red Red Ω Tip over switch Changeover switch White White 3 4 PI...

Страница 8: ...l pump 42 46 Fuel pump is idling with clicking sound 47 48 Fuel is not sprayed normally from the nozzle 49 55 Misfire lamp is lit within about 15 seconds after switching on 56 62 Overheat lamp blinks during operation in any time 63 Tip over lamp blinks during operation in any time 64 65 Overvoltage lamp lights during operation Low voltage detection is working 66 67 Combustion is not stable 68 Smok...

Страница 9: ... SA1 If the fuse is intact the transformer is short circuited Disconnect transformer connector CN 10 from burner control board then put plug into AC outlet Surge absorber SA1 on burner control is short circuited Replace a fan motor If the fuse is intact the fan coil is short circuited Unplug fan motor connector CN 15 and then start operation Fan motor is short circuited Disconnect fan motor connec...

Страница 10: ...e resistance between terminals If the fuse is intact the ignition coils is short circuited Disconnect ignition transformer connector CN 12 and then start operation Disconnect ignition transformer cord from electrode then measure its resistance If it shows 0Ω the coil of ignition transformer is short circuited Cord color Standard value black black fine few M Ω Replace an ignition transformer If it ...

Страница 11: ...voltage Cord color Standard value If it works normally thermostat connector fails on contact 18 Replace a transformer Disconnect transformer connector CN 10 from burner control then measure resistance If it shows Ω the transformer cord is disconnection If it works normally operation switch connector fails on contact Cord color Standard value Power source connector is loose connection Transformer c...

Страница 12: ... is disconnection Overheat protection is defective 21 Not applicable in above Overvoltage lamp is lit Overvoltage detection is working If excessive voltage is detected over 300V for EPX1 over 150V for EPX5 in AC outlet overvoltage detection is working Plug into a working outlet Excessive voltage is detected Measure voltage of AC outlet Standard EPX1 AC230V EPX5 AC120V 28 Replace a tip over switch ...

Страница 13: ...it board Burner control is defective Fuel pump connector CN14 is loose connection Plug connector CN14 firmly Measure voltage at terminal for fuel pump connector CN14 on burner control Cord color blue blue Standard value EPX1 AC 120 180V EPX5 AC 60 96V Replace a fuel pump If it shows AC 120 180V 60 96V the pump is defective Cord color Standard value Remove an obstacle in fan motor or replace a fan ...

Страница 14: ...Repeat start operation 2 or 3 times in order to pump air out of fuel line NEVER repeat more than 5 times in a row as fire may result Measure voltage at photo cell connector CN9 with the connector on burner control Condition Standard value in dark approx DC 5V in light less than DC 1 2V Replace a fuel pump Cord color Standard value 44 Fuel pump is inhaling air If the heater is brand new or after re...

Страница 15: ... seconds after switching on Combustion stops during the operation Replace a fuel pump Clean and flush the tank with kerosene alcohol or acetone If no fuel is pump up or fuel is not flowing at least 2 high the fuel pump is clogged or defective see exhibit How to restore the fuel flow How to check the fuel pump Nozzle is clogged Replace a nozzle Clean and flush the tank with kerosene alcohol or acet...

Страница 16: ...ormally flame monitor connector fails on contact Plug flame monitor connector CN 9 again and then turn on Flame monitor connector CN 9 is loose connection 58 Poor lighting is detected by flame monitor Remove a burner and check whether the whirl vane and inside of draft tube are clear or not If they are dirty or dustiness flame monitor cannot detect flame light properly Clean the whirl vane and ins...

Страница 17: ... fuel viscosity 69 Nozzle is clogged Replace a nozzle Clean and flush the tank with kerosene alcohol or acetone 70 Loose fitting in fuel line Confirm no loose fitting between fuel tank and fuel pump If any loose fitting exist fuel pump suck the air Tighten all fittings and repeat start operation 68 Smoke comes out Smoke is continuous for about 3 minutes or heater produces WHITE smoke Fuel viscosit...

Страница 18: ...orrect Replace a changeover switch Changeover switch cord is disconnection Changeover switch is defective If it shows 0V the burner control is defective If it shows standard voltage AC 230V EPX1 AC 120V EPX5 the fuel pump is defective 75 74 If it shows 0Ω the fuel pump coil is short circuited 78 79 Solenoid valve cord is disconnection Solenoid valve is defective Measure voltage at 1 3 PIN terminal...

Страница 19: ...stor Internal thermostat cable is defective Plug connector CN 17 firmly Disconnect adjustable resistor connector CN 16 from burner control then measure coil resistance values Standard value on each scale Ext thermo 0Ω Scale 3 1kΩ Cont 2kΩ Plug thermistor connector CN 17 again If it works normally thermistor connector fails on contact If it shows Ω or considerably abnormal value the adjustable resi...

Отзывы: