           Description of indication lamps

①Normal operation

Operation lamp is lit, but
heater doesn't start

Standby condition for
thermostat
(The preset temperature
of internal/external
thermostat is below the
ambient temperature)

Increase the preset
temperature of
thermostat.
*To keep heater running
continuously, an internal
thermostat knob is set on
"Cont." position.

Extremely high voltage is
detected

Check the voltage of
power source

Burner unit is overheated

③ Overheated

Description: When the heater
overheats, the overheated
lamp will blink

Move the heater to flat
level

⑥ Power shutdown

Description: When the power
supply is restored after it
shuts down during operation
because of blackout or other
reason, all lamp will light.

⑤ Overvoltage detected

Description: When the heater
detects extremely high-
voltage, the overvoltage lamp
will blink.

④ Tilted

Description: When the heater
topples to the ground or gets a
high impact, the tilted lamp will
blink

Remedy

Turn away form the direct
sunlight

Tighten all fittings and
repeat start-operation

Replace a Nozzle or filter
element

Status/(Timing)

Possible causes

(During the operation)

(During the operation)

Nozzle or filter element is
clogged

(At the start of the
operation)

The heater stays on
slope

Remove the causes of
overheat

Replace a nozzle or filter

(During the operation)

Power supply shuts down
such as a blackout

Standard voltage:230V (EPX1)/ 120V (EPX5)

Restart the heater

The heater gets a high
impact

② Misfire

Description: When the heater
does not ignite or the flame is
extinguished during operation,
the misfire lamp will blink.

Nozzle or filter element
may be clogged

(Within 15 seconds after
switching on)

Lens of flame monitor is
dirty or dusty

Clean the lens of flame
monitor with soft cloth

Loose fitting in fuel line

Fuel pump is idling with
clicking sound

(At the start of the
operation)

Other

Direct sunlight hits flame
monitor

①Normal operation

②Misfire

③Overheated

④Tilted

⑤Overvoltage detected

⑥Power shutdown

⑦Misfire 5 times in a row

⑧Low voltage detected

⑨Abnormal fan speed

/

 = lighting  

 = blinking

Содержание VAL6 EPX Series

Страница 1: ...VAL6 EPX Maintenance Manual ...

Страница 2: ...1 Names of components ...

Страница 3: ... Burner Control for EP6JA 2 Specifications 3 Wiring Diagram Wiring Diagram 0 75gal 60 H for H lot 0 85gal 60 H ...

Страница 4: ...on delay Fuel pre heater Plug IN Switch ON 2sec 10sec 10sec 200sec Fuel Pump pump delay post ignition post purge within 4 Sequence Time Chart Ignition Switch OFF Flame Monitor Operation Switch Fan Motor Igniter 5 ...

Страница 5: ...ilted lamp will blink Remedy Turn away form the direct sunlight Tighten all fittings and repeat start operation Replace a Nozzle or filter element Status Timing Possible causes During the operation During the operation Nozzle or filter element is clogged At the start of the operation The heater stays on slope Remove the causes of overheat Replace a nozzle or filter During the operation Power suppl...

Страница 6: ... the voltage of power source Operation is normal but the low voltage lamp is lit Less than 90 of standard voltage is detected Check the voltage of power source Voltage depression Replace a fan motor Misfire 5 times in a row Description When the heater does not ignite with five 5 consecutive tries four 4 lamps will blink Loose fitting in fuel line Start procedure is fail with five 5 consecutive tri...

Страница 7: ...andard Voltage input board Black Black fine Transformer AC 120V CN 10 CN 15 AC 230V AC 15V Solenoid pump CN 14 Ignition transformer AC 120V AC 230V approx 380Ω Chart1 Chart2 Fan motor CN 15 CN12 CN 10 0Ω CN 16 1 2 PIN 19 5kΩ 24kΩ Ω under DC1 2V approx DC5V 2kΩ 1kΩ 8 9kΩ approx a few MΩ Condition Resistance White White Red Red Ω 0Ω Ω 0Ω Red Red Ω Tip over switch Changeover switch White White 3 4 PI...

Страница 8: ...l pump 42 46 Fuel pump is idling with clicking sound 47 48 Fuel is not sprayed normally from the nozzle 49 55 Misfire lamp is lit within about 15 seconds after switching on 56 62 Overheat lamp blinks during operation in any time 63 Tip over lamp blinks during operation in any time 64 65 Overvoltage lamp lights during operation Low voltage detection is working 66 67 Combustion is not stable 68 Smok...

Страница 9: ... SA1 If the fuse is intact the transformer is short circuited Disconnect transformer connector CN 10 from burner control board then put plug into AC outlet Surge absorber SA1 on burner control is short circuited Replace a fan motor If the fuse is intact the fan coil is short circuited Unplug fan motor connector CN 15 and then start operation Fan motor is short circuited Disconnect fan motor connec...

Страница 10: ...e resistance between terminals If the fuse is intact the ignition coils is short circuited Disconnect ignition transformer connector CN 12 and then start operation Disconnect ignition transformer cord from electrode then measure its resistance If it shows 0Ω the coil of ignition transformer is short circuited Cord color Standard value black black fine few M Ω Replace an ignition transformer If it ...

Страница 11: ...voltage Cord color Standard value If it works normally thermostat connector fails on contact 18 Replace a transformer Disconnect transformer connector CN 10 from burner control then measure resistance If it shows Ω the transformer cord is disconnection If it works normally operation switch connector fails on contact Cord color Standard value Power source connector is loose connection Transformer c...

Страница 12: ... is disconnection Overheat protection is defective 21 Not applicable in above Overvoltage lamp is lit Overvoltage detection is working If excessive voltage is detected over 300V for EPX1 over 150V for EPX5 in AC outlet overvoltage detection is working Plug into a working outlet Excessive voltage is detected Measure voltage of AC outlet Standard EPX1 AC230V EPX5 AC120V 28 Replace a tip over switch ...

Страница 13: ...it board Burner control is defective Fuel pump connector CN14 is loose connection Plug connector CN14 firmly Measure voltage at terminal for fuel pump connector CN14 on burner control Cord color blue blue Standard value EPX1 AC 120 180V EPX5 AC 60 96V Replace a fuel pump If it shows AC 120 180V 60 96V the pump is defective Cord color Standard value Remove an obstacle in fan motor or replace a fan ...

Страница 14: ...Repeat start operation 2 or 3 times in order to pump air out of fuel line NEVER repeat more than 5 times in a row as fire may result Measure voltage at photo cell connector CN9 with the connector on burner control Condition Standard value in dark approx DC 5V in light less than DC 1 2V Replace a fuel pump Cord color Standard value 44 Fuel pump is inhaling air If the heater is brand new or after re...

Страница 15: ... seconds after switching on Combustion stops during the operation Replace a fuel pump Clean and flush the tank with kerosene alcohol or acetone If no fuel is pump up or fuel is not flowing at least 2 high the fuel pump is clogged or defective see exhibit How to restore the fuel flow How to check the fuel pump Nozzle is clogged Replace a nozzle Clean and flush the tank with kerosene alcohol or acet...

Страница 16: ...ormally flame monitor connector fails on contact Plug flame monitor connector CN 9 again and then turn on Flame monitor connector CN 9 is loose connection 58 Poor lighting is detected by flame monitor Remove a burner and check whether the whirl vane and inside of draft tube are clear or not If they are dirty or dustiness flame monitor cannot detect flame light properly Clean the whirl vane and ins...

Страница 17: ... fuel viscosity 69 Nozzle is clogged Replace a nozzle Clean and flush the tank with kerosene alcohol or acetone 70 Loose fitting in fuel line Confirm no loose fitting between fuel tank and fuel pump If any loose fitting exist fuel pump suck the air Tighten all fittings and repeat start operation 68 Smoke comes out Smoke is continuous for about 3 minutes or heater produces WHITE smoke Fuel viscosit...

Страница 18: ...orrect Replace a changeover switch Changeover switch cord is disconnection Changeover switch is defective If it shows 0V the burner control is defective If it shows standard voltage AC 230V EPX1 AC 120V EPX5 the fuel pump is defective 75 74 If it shows 0Ω the fuel pump coil is short circuited 78 79 Solenoid valve cord is disconnection Solenoid valve is defective Measure voltage at 1 3 PIN terminal...

Страница 19: ...stor Internal thermostat cable is defective Plug connector CN 17 firmly Disconnect adjustable resistor connector CN 16 from burner control then measure coil resistance values Standard value on each scale Ext thermo 0Ω Scale 3 1kΩ Cont 2kΩ Plug thermistor connector CN 17 again If it works normally thermistor connector fails on contact If it shows Ω or considerably abnormal value the adjustable resi...