6.3 Setup
6.3.1 Function Group
For the SE2 A, this is the function group for CH1.
To enter the function group, follow the procedures below.
(1)
Press the
key in the RUN mode until the left characters appear.
(2)
Press the
key.
For the SE2EA and SE1EA, thermocouple input range appears.
For the SE2RA and SE1RA, RTD input range appears.
For the SE2AA and SE1AA, direct current input range appears.
For the SE2VA and SE1VA, DC voltage input range appears.
Display Name, Function, Setting Range
Factory Default Value
Input range (SE2EA, SE1EA)
K -200 to 1370
• For the SE2EA and SE1EA, selects a thermocouple input range.
• Selection item:
IN
OUT
: K
: K (*)
: J
: R
: S
: B
: E
: T (*)
: N
: PL-
: W5Re/W26Re
: W3Re/W25Re
: K
: K (*)
: J
: R
: S
: B
: E
: T (*)
: N
: PL-
: W5Re/W26Re
: W3Re/W25Re
-200 to 1370
0
to 400
-200 to 1000
-50 to 1760
-50 to 1760
0
to 1820
-200 to 800
-200 to 400
-200 to 1300
0
to 1390
0
to 2315
0
to 2315
-328 to 2498
32
to 752
-328 to 1832
-58 to 3200
-58 to 3200
32
to 3308
-328 to 1472
-328 to 752
-328 to 2372
32
to 2534
32
to 4199
32
to 4199