Preface 

Thank you for purchasing our DSW-100-H, Indoor Humidity Sensor. 

This manual contains instructions for installation and handling of the DSW-100-H. To ensure safe and correct 

use, thoroughly read and understand this manual before using this sensor. To prevent accidents arising from 

the misuse of this sensor, please ensure the operator receives this manual. 

Notes 

• This sensor should be used in accordance with the specifications described in the manual. If it is not used 

according to the specifications, it may malfunction or cause a fire. 

• Be sure to follow all of the warnings, cautions and notices. If they are not observed, serious injury or 

malfunction may occur. 

• The contents of this instruction manual are subject to change without notice. 

• Care has been taken to ensure that the contents of this instruction manual are correct, but if there are any 

doubts, mistakes or questions, please inform our sales department. 

• Any unauthorized transfer or copying of this document, in part or in whole, is prohibited. 

• Shinko Technos Co., Ltd. is not liable for any damage or secondary damage(s) incurred as a result of using 

  this product, including any indirect damage.

 

Safety Precautions

 

(Be sure to read these precautions before using our products.)

 

The safety precautions are classified into 2 categories: “Warning” and “Caution”. 

Depending on the circumstances, procedures indicated by    Caution result in serious consequences, so be 

sure to follow the directions for usage. 

 

Warning

 

Procedures which may lead to dangerous conditions and cause death or serious injury, if not carried 

out properly. 

 

Caution

 

Procedures which may lead to dangerous conditions and cause superficial to medium injury or physical 

damage or may degrade or damage the product, if not carried out properly. 
 

 

Warning

 

• To prevent an electrical shock or fire, only Shinko or other qualified service personnel may handle the 

  inner assembly. 

• To prevent an electrical shock, fire or damage to the instrument, parts replacement may only be 

  undertaken by Shinko or other qualified service personnel.

 

 

SAFETY PRECAUTIONS

 

• To ensure safe and correct use, thoroughly read and understand this manual before using this 

  instrument. 

• This instrument is intended to be used for general equipment. Verify correct usage after purpose-of-use 

  consultation with our agency or main office.   

(Never use this instrument for medical purposes with which human lives are involved.) 

• External protection devices must be installed, as malfunction of this product could result in serious 

damage to the system or injury to personnel. Proper periodic maintenance is also required.   

• This instrument must be used under the conditions and environment described in this manual.   

Shinko Technos Co., Ltd. does not accept liability for any injury, loss of life or damage occurring due to 

the instrument being used under conditions not otherwise stated in this manual.

 

 

Caution with Respect to Export Trade Control

 

Ordinance 

To avoid this instrument from being used as a component in, or as being utilized in the manufacture of 

weapons of mass destruction (i.e. military applications, military equipment, etc.), please investigate the 

end users and the final use of this instrument. 

In the case of resale, ensure that this instrument is not illegally exported.

 

和文は裏面をご覧ください。

 

Содержание DSW-100-H

Страница 1: ...lead to dangerous conditions and cause death or serious injury if not carried out properly Caution Procedures which may lead to dangerous conditions and cause superficial to medium injury or physical damage or may degrade or damage the product if not carried out properly Warning To prevent an electrical shock or fire only Shinko or other qualified service personnel may handle the inner assembly To...

Страница 2: ...sive gases No mechanical vibrations or shocks No exposure to direct sunlight an ambient temperature of 0 to 50 32 to 122 that does not change rapidly and no icing An ambient non condensing humidity of 5 to 90 RH An absence of chlorinated and sulfidizing gases No large capacity electromagnetic switches or cables through which large current is flowing No water oil chemicals or the vapors of these su...

Страница 3: ...ty sensitive so be sure to insert the sensor correctly otherwise the sensor will be broken and measurement will be impossible Never disassemble the humidity sensor as it may lead to malfunction 4 Mount the main unit cover then turn the power to the unit ON Socket Humidity sensor HD S2 3 Mounting Main Unit Screw 4 places C as indicated by the dotted lines and fix the sensor main unit to the Mountin...

Страница 4: ...m up period 60 minutes The output accuracy will be affected if the conditions above are changed Response characteristics Approx 20 seconds Time to reach 90 of the RH value when the RH shifts between 30 85 RH However airflow 5 l min 0 16 m s Waterproof filter attached Hysteresis Approx 0 RH Stabilization time 20 minutes Power Consumption Approx 550 mW 2 wire type Approx 3 W 4 wire type Operating En...

Отзывы: