FOREWORD 

WK

 

 

iii 

 

To ensure safe use of this equipment, strictly observe the safety precautions provided in this manual, as well 

as installation methods and methods of use stipulated by laws and regulations. SHINKAWA Sensor 

Technology will not be liable for damage, etc. due to methods of use contravening to the instructions provided 

here. 

 Safe use 

         

WARNING

 

Make sure to ground. 

May cause electric shock or malfunction. 

 

Make sure to turn the power off before any wiring work.

 

Will cause electric shock. 

 

         

CAUTION

 

Make sure that the supply connected to the Power / Output terminal has 
the specified voltage.   

Will cause damage and malfunction of the instrument. 

The equipment is a precision instrument. 
Take care not to expose it to excessive shock or vibration. 

Do not change the parameter settings during operation. 

May cause unexpected alarm output. 

Do not measure insulation resistance and dielectric strength other than 
those at places specified. 

Will cause damage to the instrument.   

Do not remodel this monitor unit without permission

Otherwise the guarantee can not be made. 

PROHIBITION 

Connect earth wire 

PROHIBITION 

MANDATORY 

PROHIBITION 

PROHIBITION 

PROHIBITION 

Содержание WK Series

Страница 1: ...MANUAL NO 20101E2 6 Published in Jul 2001 Revised in Aug 2008 WK SERIES WK 142 K 2 WIRE VIBRATION TRANSMITTER INSTRUCTION MANUAL ...

Страница 2: ...ged 2 The connector connecting the sensor cable and the extension cable shall be insulated with the attached insulation sleeve transparent shrink tube or fluoro resin insulation tape The vinyl insulating tape shall not be used which may cause the wiring trouble in the case of the temperature more than 80 C 3 Do not measure insulation resistance and withstand voltage other than those at places spec...

Страница 3: ...t in minor or moderate injury It may also be used to permit for property damage only accidents Serious injury refers to such injuries as loss of eyesight injuries burns due to heat or cold electric shock fractures and poisoning that have permanent aftereffects and require hospitalization or long term outpatient treatment Moderate or minor injury refers to such injuries as burns and electric shock ...

Страница 4: ...ause electric shock CAUTION Make sure that the supply connected to the Power Output terminal has the specified voltage Will cause damage and malfunction of the instrument The equipment is a precision instrument Take care not to expose it to excessive shock or vibration Do not change the parameter settings during operation May cause unexpected alarm output Do not measure insulation resistance and d...

Страница 5: ...g the system and these devices install a surge killer The transmitter should be put into the EMC shield enclosure if the transmitter is installed at noisy surroundings And the enclosure should be grounded for EMC shield grounding The signal transmitter cable sensor cable and extension cable should be lay into the metal conduit if the cable passes through noisy surroundings And the conduit should b...

Страница 6: ...itted through in each cable may be rejected to some extent by inserting a ferrite core in the cable note 1 If the cable passes through noisy surroundings it is recommended that such a noise prevention device is used note 1 ZCAT3050 1330 TDK ...

Страница 7: ...ONSIDERATIONS 5 3 3 RELATION BETWEENTARBGET SHAPE AND SENSOR 6 3 4 EFFECT OF INSTALLING CONDITIONS 6 3 5 WK TRANSMITTER INSTALLATION 8 4 INTERCONNECTION 4 1 INTERCONNECTION OF SYSTEM COMPOSITION PARTS 9 4 2 CONNECTOR INSTALLATION 9 4 3 CONNECTION OF SIGNAL TRANSMITTER CABLE 10 4 4 WIRING 11 5 CALIBRATION 5 1 CALIBRATION 13 6 MAINTENANCE INSPECTION 6 1 PERIODIC INSPECTION 14 6 2 TROUBLESHOOTING 15 ...

Страница 8: ...e proportioned to gap from gap out terminal and BNC connector Vibration amplitude can be measured by 4 to 20 mA output as consumption of current loop 1 2 RECEIVING INSPECTION When the unit is received inspect it for damage suffered in transport and check whether it is the item you ordered In the unlikely event that it was damaged in transport or does not function according to specifications please...

Страница 9: ... the change of the cable capacitance 3 MEGGER TEST OF SIGNAL CABLE If megger test is made on the signal cable 2 wire shielded cable be sure to discharge the charged electric load before connecting the cable to transmitter If this caution is not adhered the transmitter could be damaged 4 WIRING BETWEEN GAP OUT TERMINAL AND EQUIPMENT a Non grounding type equipment Connect directly with coaxial cable...

Страница 10: ...9 2in e g 04 0 4in L1 L2 0 7in 0 1in step 0 8 to 9 9in e g 35 3 5in 4 7 0m T With With Fluoro resin coating inch for UNF 2A thread mm for M thread L Without Dimensions mm inch 3 0 L1 3 2 5 0 L2 L3 30 0 7 1 5 5 Sensor tip Jam nut Thread Wrench flat Flexible armor Coaxial cable 2 7 Coaxial connector Model code Serial No Sensor side 2 7 6 8 8 0 7 1 Transmitter side L 30 0 Coaxial cable Coaxial connec...

Страница 11: ...o GAP OUT SENSOR 74 63 5 Logo Sensor Input Connector 70 2 76 Name plate Power Output Gap out 4 φ 4 3 Model code and Ser No 9 0 354 2 91 2 50 0 169 Gap out 100 3 94 25 5 50 1 97 1 00 Insulator Dimensions mm inch DIN Mounting Clips Option C WK 142K1 2 5m system Vibration 0 125µm pk pk Ser No AV01234 Tag No 1234 01 D E A B NB1 DNC CEM WK 142K System Cable length Output Range Non incendive With DIN Mo...

Страница 12: ...ial The system can measure the gap in the linear range Recommended standard setting gap is 0 9 mm CAUTION 1 Install and fix the sensor to keep the gap within the linear range to prevent contact with target or out of linear range 2 Be careful not to damage or scratch the sensor tip and target surface with thickness gauge Take care the effect for output characteristics by the relation between target...

Страница 13: ...ance X 8mm There is effect When the sensor Neighborhood is Countersunk There is effect Distance Y 15mm There is effect Gap X 0 3mm Too close to measure because of dead zone Gap X1 Gap X2 There is effect X Target Mounting Plate X Y Mounting Plate Target Mounting Plate Target X Target Mounting Plate Mounting Plate Target Y Mounting Plate Target X Target Mounting Plate X2 X1 Mounting Plate Target d 1...

Страница 14: ... to ensure accurate vibration detection 1 The target surface must be more than 3 times the sensor tip diameter fig 3 1 a 2 There must not be any conductive materials within a range of 3 times the sensor tip diameter fig 3 1 b 3 To avoid mutual interference between sensors a minimum distance corresponding to 5 times the sensor tip diameter must be maintained between sensors fig 3 1 c 4 Use a suffic...

Страница 15: ...because of grounding the body Tightening Torque 1 18N m 12kgf cm or less 3 5 2 DIN Mounting Clips When fixing DIN mounting clips by user When user fixes DIN mounting clips before using screw up and fix the DIN mounting clips on the bottom surface of WK transmitter with insulation bushings and screws as shown below CAUTION Use the insulation bushing and washers to prevent earth fault via DIN rail M...

Страница 16: ...ly in the direction of that the resulting repulsive force acts to tighten the connector Then connect the connector and tighten SHINKAWA Electric recommends to take up the surplus length of the extension cable by winding it into a cable box If the excessive extension cable needs to be accommodated in the housing for some unavoidable reasons do not push it forcibly in the housing and also do not cut...

Страница 17: ...OD Vibration and displacement signals can exit in one instrument cable A high amplitude vibration signal exerts injurious influence over other displacement and vibration signals in a common cable Therefore separate cables must be used Recommended Outside shield of aluminum or copper tape CAUTION 1 For cable wiring for pulse signals phase marker revolution separate them from cables for vibration tr...

Страница 18: ...llowing wiring diagrams to connect the field wiring between the transmitter and the monitoring instruments Receiver Receiver 1000 500 0 Maximum Loop Resistance Power Supply Voltage 35 30 25 20 15 12 VPS Ω OPERATING REGION RLOOP 43 5 x VPS 12 Ω max Cable Shield Power Supply VPS 17 to 35 VDC Receiver Cable Shield Power Supply VPS 17 to 35 VDC Receiver Cable Shield Power Supply VPS 17 to 35 VDC Recom...

Страница 19: ...ered Test Equipment Non grounding type equipment With 1 MΩ Min Isolated Input Output will drop approximately 1 down Isolator Grounding type Equipment Common Ground Battery Powered Test Equipment Non grounding type equipment With 1 MΩ Min Isolated Input Output will drop approximately 1 down Recommended wiring is shielded Twisted pair 1 0 mm2 18 AWG ordered separately Max length 1 km 0 62 miles ...

Страница 20: ...ut terminal block 3 Adjust span potentiometer with full scale test signal CAUTION Oscillator does not connect to ground Test Signal none 4 mA 1 V F S Test signal OSC Output 100 µm 787 mV pk pk 125 µm 984 mV pk pk 200 µm 1 574 mV pk pk 250 µm 1 968 mV pk pk 400 µm 3 148 mV pk pk 20 mA 5 V SPAN Adjust Potentiometer Refer to 5 1 2 ZERO Adjust Potentiometer Refer to 5 1 1 Test Signal Input Pin Refer t...

Страница 21: ...type equipment Therefore please use the voltmeter which is more than 1MΩ input impedance 4 Refer to 7 1 Standard static characteristic P16 and make sure that the desired set gap voltage is gained Data indicated in 7 1 Standard static characteristic are measured for a JIS SCM440 AISI 4140 equivalent flat target diameter more than 15mm When the target material or shapes differ the output characteris...

Страница 22: ...Far distance between target and sensor 1 Measure distance 1 Adjust 2 Open circuit in sensor 2 Measure resistance Normally approx 4Ω 0 22 Ω m 2 Replace 3 Faulty transmitter 3 Replace 3 Gap output does not change from approx 16V 4 Is connector securely connected 4 Connect securely 1 Power is not supplied 1 Measure power supply voltage 1 Supply power 4 Current output is zero and no change 2 Faulty tr...

Страница 23: ...C CHARACTERISTICS Target material JIS SCM440 flat dia 15mm or more 0 2 4 6 8 10 12 14 16 0 00 0 20 0 40 0 60 0 80 1 00 1 20 1 40 1 60 1 80 2 00 GAP mm Output V 15 10 5 0 5 10 15 0 00 0 20 0 40 0 60 0 80 1 00 1 20 1 40 1 60 1 80 2 00 GAP mm SCF Error ...

Страница 24: ......

Страница 25: ...ue to a reason other than by the fault of our company 3 If there were modifications or repairs made by a party other than our company or persons specified by our company 4 Handling storage or usage under severe environments exceeding design specification conditions 5 Problems caused by fires floods earthquakes lightning strikes and other natural disasters 6 Consumable parts 7 Other failures that a...

Страница 26: ...Hiroshima Factory 4 22 Yoshikawa kogyodanchi Higashihiroshima 739 0153 Japan Tel 81 82 429 1118 representative Fax 81 82 429 0804 Service department Email service sst shinkawa co jp ...

Отзывы: