Section 3 Installation
VM-21P 3-Wire LVDT Signal Conditioner Instruction Manual
- 27 -
3.3.4 Checking
connections
Check the following before turning on the power supply.
●
Make sure there is no looseness in connection terminals, and that all wiring has been
connected correctly.
●
Make sure that the wiring for the power supply is connected to one of the power supplies
indicated below.
24V DC power supply specifications: 24VDC
±
10
%
100-240V AC/DC power supply specifications: 85 to 264VAC/DC
●
Make sure the product is installed in a location that satisfies the installation environment
requirements.
In particular, make sure there are no flaws in the installation of the product, and that it has
not been installed in any of the following types of areas.
- Areas with high temperature or high humidity
- Areas with a large amount of dust
- Areas susceptible to vibration
This completes the installation of the product.
Make corrections as necessary after assembling this product with other instrumentation.
(
☞
Page 28)
Point
The output of this product might overshoot , when the power supply is torned on.
Be afraid of need , please establish a safe system.