![Shini STM-1213-HPW Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/shini/stm-1213-hpw/stm-1213-hpw_manual_1258098049.webp)
49(50)
6.6 Maintenance Schedule
6.6.1 About the Machine
Model SN Manufacture date
Voltage
Ф
V Frequency Hz Power kW
6.6.2 Installation & Inspection
Check the installation space is enough as required.
Check the pipes are correctly connected.
Electrical installation
Voltage: V Hz
Fuse melting current: 1 Phase A 3 Phase A
Check phase sequence of power supply.
6.6.3 Daily Checking
Check machine startup function.
Check all the electrical wires.
6.6.4 Weekly Checking
Check loose eletrical connections.
Check and clean Y type filter
1
.
Check solenoid valve.
Check motor overload and phase reversal alarm function.
Check whether pipeline joints are under looseness.
Check the sensitivity of EGO.
6.6.5 Trimonthly Checking
Check level switch.
Check the contactor
2
.
Replace the hot kerosene with a using temperature above 160 degree
3
.
6.6.6 Half-yearly Checking
Check damaged pipes.
Clean process heater/cooler.
Check indicator and buzzer.
Содержание STM-1213-HPW
Страница 1: ...STM PW Series High Temp Water Heater Date Apr 2013 Version Ver B English ...
Страница 2: ......
Страница 22: ...22 50 2 3 Electrical Diagram 2 3 1 Main Circuit STM 940HPW 230V Picture 2 4 Main Circuit STM 940HPW 230V ...
Страница 23: ...23 50 2 3 2 Control Circuit STM 940HPW 230V Picture 2 5 Control Circuit STM HPW 230V ...
Страница 25: ...25 50 2 3 4 Electrical Components Layout STM 940HPW 230V Picture 2 7 Electrical Components Layout STM HPW 230V ...
Страница 27: ...27 50 2 3 6 Main Circuit STM 940HPW 400V Picture 2 8 Main Circuit STM 940HPW 400V ...
Страница 28: ...28 50 2 3 7 Control Circuit STM 940HPW 400V Picture 2 9 Control Circuit STM HPW 400V ...