41(50)
●
Setting value: Display set temperature value or parameter value, or display
input value when you set parameters.
●
Operation indicator
1. ALM1 (alarm 1)
This indicator becomes bright to indicate that heater 2 has stopped
working. Alarm 1 function is used to control pipe heater 2. When actual
temperaure is 5
℃
less than setting value, heater 2 will be cut off. (Only for
machine with dual-heating zone
)
2. ALM2 (alarm 2)
Alarm 2 function is not used on this unit.
3. ALM3 (alarm 3)
Alarm 3 function is not used on this unit.
4. HB (heater break)
When heater break is detected, this indicator will become bright.
5. OUT1 (output control 1)
OUT1 is used for heating control. When it is bright, it means that pipe
heater is working.
6. OUT2 (output control 2)
OUT2 is used for cooling control. When it is bright, cooling water valve is
open and cooling function is in process.
7. STOP (stop)
When stop indicator is bright, it means that temperature controller is not
working. Temperature controller operation mode is set to STOP.
Note! Do not set operation mode to stop, which will force temperaure
controller to stop working.
4.4.2 Keys on Control Panel
:
(Menu) press this key to show the items you want to reset.
:
(Mode) press this key to choose a parameter.
:
(Increase value) press this key to increase setting value.
:
(Decrease value) press this key to decrease setting value.
4.4.3 Choose a Parameter
Содержание STM-1213-HPW
Страница 1: ...STM PW Series High Temp Water Heater Date Apr 2013 Version Ver B English ...
Страница 2: ......
Страница 22: ...22 50 2 3 Electrical Diagram 2 3 1 Main Circuit STM 940HPW 230V Picture 2 4 Main Circuit STM 940HPW 230V ...
Страница 23: ...23 50 2 3 2 Control Circuit STM 940HPW 230V Picture 2 5 Control Circuit STM HPW 230V ...
Страница 25: ...25 50 2 3 4 Electrical Components Layout STM 940HPW 230V Picture 2 7 Electrical Components Layout STM HPW 230V ...
Страница 27: ...27 50 2 3 6 Main Circuit STM 940HPW 400V Picture 2 8 Main Circuit STM 940HPW 400V ...
Страница 28: ...28 50 2 3 7 Control Circuit STM 940HPW 400V Picture 2 9 Control Circuit STM HPW 400V ...