Heating ratio 
Rang:1-100

 

Default:40

   

       


Integral 
Rang:0-999S 
Default:120S     

     


Differential 
Rang:0-999S 
Default:20S       

   

OTP 
Overheat  temp. 

protection 

(SV+F-05) 
Rang:2-50

 

Default:15

   

       

100C 

HCLE 

Heating cycle 
Rang:15-60S 

Default:15S   

     

OFF1 
Mon. off time 
00:00=OFF 

             

OFF2 
Tues. off time 
00:00=OFF 

             

OFF3 
Wed. off time 
00:00=OFF 
   

OFF4 
Thur. off time 

00:00=OFF 

             

OFF5 
Fri.  off  time 
00:00=OFF 

 

           

OFF6 
Sat. off time 

00:00=OFF 

 

           

OFF7 
Sun. off time 

00:00=OFF 

ON 1 
Mon. start time 

00:00=OFF 

ON 2 
Tues. start 

time 

00:00=OFF 

ON 3 
Wed. start time 
00:00=OFF 

             

ON 4 
Thur. start 

time 

00:00=OFF 

ON 5 
Fri. start time 
00:00=OFF 

 

           

ON 6 
Sat. start time 

00:00=OFF 

 

           

ON 7 
Sun. start 

time 

00:00=OFF 

TIME 
Current 
Time(hr,min) 

             

RON 
Intermittent run ON 
time 
Rang :30-600 (Min) 
Default:30 

             

ROFF 
Intermittent run OFF 
time 
Rang:0 

 600(Min) 

Default:0

           

RONE 
Intermittent intial 
run time 
Range:30-600(Min) 
Default:90 

UNIT 
Temperture unit 

Rang:

-

 

Default:

 

 

       

AUTO 
Timing start/stop 
Rang

AUTO-OFF 

Default:OFF 

WEEK 
Current Time   
(hr,min) 

 

FDLY 
Blower delay 

Rang:30-360S 

Default:180S     

     

LOCK 
SV setting lock 
Rang: YES

 NO 

Default:NO 

PRO 
Communiation 
protocol 
Rang: 
MODBUS-RTU   

       

ID 
Communiation 
ID    Rang:1-99 
Default:1       

     

BAUD 
Rang:4.8K  9.6K 
19.2K 
Default:9.6K             

PAR 
Parity bit 
Rang:NONE

Odd

Even 

Default:Odd     

     

Data 
Data length 
Rang:8bit 
Default: 8bit 

         

Stop 
Stop bit 
Rang: 1bit

2bit 

Default: 1bit       

   

M+

+3S 

SV 
Rang:0-200

 

Default:90

 

 

       

100C 

M+2S 

M+5S 

M+

+3S 

M+7S 

/

 

/

 

/

 

/

 

/

 

M

 

Exit

 

 

ALPH 

Control coefficient 
Rang:0~100 

Preset value:50   

       

BIAS 

Temp. correction 

Rang:-99~100

 

Preset value:0   

       

RJC 

PC Temp. 
Rang: 0~100

 

temp.read only 

       

AT 
Self-tuning 
Rang: YES

 NO 

Default:NO 

M stands for

 

Menu key 

/

stands for

 

Up/Down key 

4.1.8  Operation Flow   

 

Содержание SHD-E

Страница 1: ...SHD E Standard Hopper Dryer Date Jul 2022 Version Ver C...

Страница 2: ......

Страница 3: ...14 2 2 4 Blower Inlet Filter 14 2 2 5 Hopper Magnet 14 2 2 6 European Suction Box Shut off Suction Box 15 2 2 7 N Type Floor Stand 15 3 Installation and Debugging 17 3 1 Direct Installation 17 3 2 Pow...

Страница 4: ...Table 13 Table 2 2 Configuration Table 13 Table 2 3 Configuration Table 14 Table 2 4 Configuration Table 14 Table 4 1 PID Setting Parameter 24 Table 4 2 Communication Setting Parameter 25 Table 4 3 Er...

Страница 5: ...5 29 Picture 3 7 HAR Hot air recycler 21 Picture 4 1 Control Panel 22...

Страница 6: ...6 29 1 General Description Please read through this operation manual before using the machine to prevent damages of the machine or personal injuries Picture 1 1 SHD 50E...

Страница 7: ...by lead sheets and other models are equipped with temperature protector to prevent heater pipe from damaging by blower fault Overheat tripping can automatically cut off power when drying temperature...

Страница 8: ...ny modifications of the machine must be approved by SHINI in order to avoid personal injury and damage to machine We shall not be liable for any damage caused by unauthorized change of the machine Our...

Страница 9: ...20 SHD 150E 150 150 150 115 60 27 22 15 45 52 75 30 90 SHD 100E 100 100 100 80 40 20 16 10 30 35 50 20 60 SHD 75E 75 75 75 57 30 13 11 7 22 26 37 15 45 SHD 50E 50 50 50 38 20 10 8 5 12 17 25 10 30 SHD...

Страница 10: ...switch are suitable and reliable When the machine is under care or maintenance turn off both power switch and automatic operation switch 1 2 1 Safety Signs and Labels Danger High presscure It is atta...

Страница 11: ...from Shini including employees and agents Shini is exempted from liability for any costs fees claims and losses caused by reasons below 1 Any careless or man made installations operation and maintenan...

Страница 12: ...n away by hot air thus to gain a satisfied drying effect Air blown out of blower via pipe heater became high temperature drying air after being heated Through shade separator and screen protector hot...

Страница 13: ...Configuration Table Model Filtering Barrel Dia mm Inlet Air Pipe Dia inch Flange of Air Outlet inch Applied to HAR 12 157 2 SHD 12E HAR 25EB 157 2 5 SHD 25E HAR 50 177 3 SHD 50E 75E HAR 100EB 219 3 SH...

Страница 14: ...Table Model Filtering Barrel Dia mm Overall height mm Applied to AIF 12 157 195 SHD 12E AIF 25EB 157 195 SHD 25E AIF 50 177 201 SHD 50E 75E AIF 100EB 219 191 SHD 100E 150E AIF 200EB 249 268 SHD 200E...

Страница 15: ...s for single tube suction box and D stands for double tubes suction box 5 It must use with the floor stand 2 2 7 N Type Floor Stand Model Applied to Dimension H W D mm A B C mm FSN 50 SHD 12E 75E 600...

Страница 16: ...16 29 the SHD E series...

Страница 17: ...ce around the machine Please keep at least 2m distance between the device and the inflammable goods 3 This series of models only could be applied in working environment with good ventilation 3 1 Direc...

Страница 18: ...L3 to the live wires and the earth PE to the ground Power supply requirements Main power voltage 5 Main power frequency 2 Please refer to the circuit diagram of each model for specific power access sp...

Страница 19: ...workshop s environment Option with air exhaust filter ADC can filter the exhausted air from the dryer ADC can reach filter efficiency of 99 ADC is installed on air exhaust elbow of the dryer Point it...

Страница 20: ...on of European suction box and shut off suction box is simple Install them at bottom of the hopper point to the holes and tighten up the screws Picture 3 5 Shut off suction box 3 4 3 Blower Inlet Filt...

Страница 21: ...e AIF at blower inlet port point to the holes and tighten up the screws 3 4 4 Hot Air Recycler Installation Based on AIF blower inlet filter using a hear resistance pipe to connect the hopper exhausti...

Страница 22: ...Temperature Setting 1 The setup number will flicker after pressing Setting key add or decrease temperature by pressing Up or Down key 2 Press Setting key again to confirm the input value 4 1 3 Temper...

Страница 23: ...ey the set value flickers then press Up or Down key to add or decrease the value 3 Press Setting key to confirm the input value 4 Press Up key again and again it displays I integral time and D differe...

Страница 24: ...to set OFF1 Mon off time OFF2 Tues off time OFF3 Wed off time OFF4 Thur off time OFF 5 Fri off time OFF6 Sat off time OFF7 Sun off time 2 Hold Menu for about 7S press Up or Down key to set ON1 Mon st...

Страница 25: ...s Baud and PAR settings as below 7 Repeat step 3 and step 4 then confirm the related input parameters 8 Press Menu key to return operation menu Table 4 2 Communication Setting Parameter Communication...

Страница 26: ...ng 30 600 Min Default 30 ROFF Intermittent run OFF time Rang 0 600 Min Default 0 RONE Intermittent intial run time Range 30 600 Min Default 90 UNIT Temperture unit Rang Default AUTO Timing start stop...

Страница 27: ...le 4 3 Error Code Description Wrong Codes Remark bR Thermocouple break oH Overheat REV Temperature sensor reversely connected oL Overload bAT Battery error EGO EGO Over temp xATx Auto turning error LT...

Страница 28: ...e blower regularly especially the air inlet path to remove the dust on surface 2 Eliminate the blower s dirt regularly to avoid the blower damage Note No need for regular inspection because all the el...

Страница 29: ...lower runs while 1 Lead sheet of heater pipe melted 2 Magnetic switch fault 3 Heater fault 4 Controller fault 5 Thermocouple fault 1 Check and change 2 Check and change 3 Check and change 4 Check and...

Отзывы: